{"title":"基于 PPY-fMWCNT 纳米复合材料的化学电容性生物传感器用于超灵敏检测人体血浆中创伤性脑损伤特异性 GFAP 生物标记物","authors":"Patta Supraja;Rahul Gangwar;Suryasnata Tripathy;Siva Rama Krishna Vanjari;Shiv Govind Singh","doi":"10.1109/LSENS.2024.3497003","DOIUrl":null,"url":null,"abstract":"Traumatic brain injury (TBI) is physical damage to the brain and a significant cause of mortality and morbidity affecting all ages worldwide, remaining as a diagnostic and therapeutic challenge to date. The design and development of rapid, low cost, highly accurate, and long-term stable point-of-care TBI diagnostic test kits is an unmet clinical need. In light of this, here we report a novel multianalyte chemicapacitive immunosensing platform that can detect FDA-approved Glial Fibrillary Acidic Protein (GFAP) biomarkers in real-time human plasma samples using carboxylic functionalized MWCNTs (fMWCNTs) embedded Polypyrrole (PPY) as a bioelectrical transducer. Herein, the low-cost GFAP bioelectrodes were prepared through covalent immobilization of anti-GFAP-antibodies on PPY-fMWCNTs modified array of interdigitated microelectrodes (IDµEs, fabricated on low-cost single-side copper clad PCB substrates). The binding event of GFAP peptides with anti-GFAP-antibodies in real-time human plasma samples was captured in terms of ac capacitance measured through C-F analysis (using an Agilent B1500A parametric analyzer) and quantified in terms of normalized change in capacitance of GFAP bioelectrodes with and without exposure of target GFAP peptides spiked in real-time human plasma samples (10 fg/mL – 1 µg/mL). The proposed PPY-fMWCNTs nanocomposite-based chemicapacitive immunosensing platform effectively detected GFAP target analytes in linear detection range 10 fg/mL – 10 ng/mL with a sensitivity and LoD of 3.9743 ((ΔC/C\n<sub>0</sub>\n)/ng·mL\n<sup>−1</sup>\n)/cm\n<sup>2</sup>\n and 0.3854 fg/mL, respectively. Further, it also showed superior performance in terms of selectivity, reproducibility, long-term stability (30 weeks) and interference resistance. The proposed ac-capacitive approach is facile, label-free and can be combined with dc-resistive measurements to improve the diversity of decision-making parameters that inherently aid in improving the diagnostic accuracy of TBI test kit.","PeriodicalId":13014,"journal":{"name":"IEEE Sensors Letters","volume":"8 12","pages":"1-4"},"PeriodicalIF":2.2000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PPY-fMWCNT Nanocomposite-Based Chemicapacitive Biosensor for Ultrasensitive Detection of TBI-Specific GFAP Biomarker in Human Plasma\",\"authors\":\"Patta Supraja;Rahul Gangwar;Suryasnata Tripathy;Siva Rama Krishna Vanjari;Shiv Govind Singh\",\"doi\":\"10.1109/LSENS.2024.3497003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Traumatic brain injury (TBI) is physical damage to the brain and a significant cause of mortality and morbidity affecting all ages worldwide, remaining as a diagnostic and therapeutic challenge to date. The design and development of rapid, low cost, highly accurate, and long-term stable point-of-care TBI diagnostic test kits is an unmet clinical need. In light of this, here we report a novel multianalyte chemicapacitive immunosensing platform that can detect FDA-approved Glial Fibrillary Acidic Protein (GFAP) biomarkers in real-time human plasma samples using carboxylic functionalized MWCNTs (fMWCNTs) embedded Polypyrrole (PPY) as a bioelectrical transducer. Herein, the low-cost GFAP bioelectrodes were prepared through covalent immobilization of anti-GFAP-antibodies on PPY-fMWCNTs modified array of interdigitated microelectrodes (IDµEs, fabricated on low-cost single-side copper clad PCB substrates). The binding event of GFAP peptides with anti-GFAP-antibodies in real-time human plasma samples was captured in terms of ac capacitance measured through C-F analysis (using an Agilent B1500A parametric analyzer) and quantified in terms of normalized change in capacitance of GFAP bioelectrodes with and without exposure of target GFAP peptides spiked in real-time human plasma samples (10 fg/mL – 1 µg/mL). The proposed PPY-fMWCNTs nanocomposite-based chemicapacitive immunosensing platform effectively detected GFAP target analytes in linear detection range 10 fg/mL – 10 ng/mL with a sensitivity and LoD of 3.9743 ((ΔC/C\\n<sub>0</sub>\\n)/ng·mL\\n<sup>−1</sup>\\n)/cm\\n<sup>2</sup>\\n and 0.3854 fg/mL, respectively. Further, it also showed superior performance in terms of selectivity, reproducibility, long-term stability (30 weeks) and interference resistance. The proposed ac-capacitive approach is facile, label-free and can be combined with dc-resistive measurements to improve the diversity of decision-making parameters that inherently aid in improving the diagnostic accuracy of TBI test kit.\",\"PeriodicalId\":13014,\"journal\":{\"name\":\"IEEE Sensors Letters\",\"volume\":\"8 12\",\"pages\":\"1-4\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Sensors Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10753623/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors Letters","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10753623/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
PPY-fMWCNT Nanocomposite-Based Chemicapacitive Biosensor for Ultrasensitive Detection of TBI-Specific GFAP Biomarker in Human Plasma
Traumatic brain injury (TBI) is physical damage to the brain and a significant cause of mortality and morbidity affecting all ages worldwide, remaining as a diagnostic and therapeutic challenge to date. The design and development of rapid, low cost, highly accurate, and long-term stable point-of-care TBI diagnostic test kits is an unmet clinical need. In light of this, here we report a novel multianalyte chemicapacitive immunosensing platform that can detect FDA-approved Glial Fibrillary Acidic Protein (GFAP) biomarkers in real-time human plasma samples using carboxylic functionalized MWCNTs (fMWCNTs) embedded Polypyrrole (PPY) as a bioelectrical transducer. Herein, the low-cost GFAP bioelectrodes were prepared through covalent immobilization of anti-GFAP-antibodies on PPY-fMWCNTs modified array of interdigitated microelectrodes (IDµEs, fabricated on low-cost single-side copper clad PCB substrates). The binding event of GFAP peptides with anti-GFAP-antibodies in real-time human plasma samples was captured in terms of ac capacitance measured through C-F analysis (using an Agilent B1500A parametric analyzer) and quantified in terms of normalized change in capacitance of GFAP bioelectrodes with and without exposure of target GFAP peptides spiked in real-time human plasma samples (10 fg/mL – 1 µg/mL). The proposed PPY-fMWCNTs nanocomposite-based chemicapacitive immunosensing platform effectively detected GFAP target analytes in linear detection range 10 fg/mL – 10 ng/mL with a sensitivity and LoD of 3.9743 ((ΔC/C
0
)/ng·mL
−1
)/cm
2
and 0.3854 fg/mL, respectively. Further, it also showed superior performance in terms of selectivity, reproducibility, long-term stability (30 weeks) and interference resistance. The proposed ac-capacitive approach is facile, label-free and can be combined with dc-resistive measurements to improve the diversity of decision-making parameters that inherently aid in improving the diagnostic accuracy of TBI test kit.