{"title":"呼吸功能指示灯对新生儿复苏期间视觉注意力和通气质量的影响:随机对照交叉模拟试验。","authors":"Yasuhisa Ikuta, Fumihiko Takatori, Shoichiro Amari, Ai Ito, Akira Ishiguro, Tetsuya Isayama","doi":"10.1515/jpm-2024-0251","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To investigate the effectiveness of placing an indicator light indicating inadequate ventilation near the face mask during positive-pressure ventilation with respiratory function monitors (RFMs) in neonatal resuscitation. The study is a three-group, randomised, controlled, crossover simulation trial.</p><p><strong>Methods: </strong>Paediatrics residents, neonatology fellows, and attending neonatologists at a single neonatal intensive care unit. A ventilation simulation with a manikin was performed three times consecutively using the same scenario with three different ventilation evaluation methods (A) RFM plus indicator light and conventional methods (heart rate and chest rise) (B) RFM and conventional methods, and (C) conventional methods alone.</p><p><strong>Results: </strong>The ratio of gaze duration on the manikin to the total trial duration was recorded using an eye-tracking device. The proportion of trials with adequate ventilation (expiratory tidal volume [VTe], 4-10 mL/kg; peak inspiratory pressure <30 cm H<sub>2</sub>O; leak <40 %) was determined. After excluding incomplete data, 63 simulations (22 participants) were analysed. The ratios of the gaze duration on the manikin to the total trial duration were significantly different among settings A (0.60 [95 % confidence interval: 0.52-0.67] sec/sec), B (0.51 [0.43-0.59] sec/sec), and C (0.80 [0.76-0.84] sec/sec). Ventilation with adequate VTe and less leakage was more frequent in settings A and B than in setting C (adequate VTe: A, 91 %; B, 91 %; and C, 83 %; less leak: A, 76 %; B, 78 %; and C, 57 %).</p><p><strong>Conclusions: </strong>An indicator light close to the facemask with an RFM directed the eyesight towards the manikin without compromising the ventilation quality during the simulation of neonatal resuscitation.</p>","PeriodicalId":16704,"journal":{"name":"Journal of Perinatal Medicine","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of a respiratory function indicator light on visual attention and ventilation quality during neonatal resuscitation: a randomised controlled crossover simulation trial.\",\"authors\":\"Yasuhisa Ikuta, Fumihiko Takatori, Shoichiro Amari, Ai Ito, Akira Ishiguro, Tetsuya Isayama\",\"doi\":\"10.1515/jpm-2024-0251\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To investigate the effectiveness of placing an indicator light indicating inadequate ventilation near the face mask during positive-pressure ventilation with respiratory function monitors (RFMs) in neonatal resuscitation. The study is a three-group, randomised, controlled, crossover simulation trial.</p><p><strong>Methods: </strong>Paediatrics residents, neonatology fellows, and attending neonatologists at a single neonatal intensive care unit. A ventilation simulation with a manikin was performed three times consecutively using the same scenario with three different ventilation evaluation methods (A) RFM plus indicator light and conventional methods (heart rate and chest rise) (B) RFM and conventional methods, and (C) conventional methods alone.</p><p><strong>Results: </strong>The ratio of gaze duration on the manikin to the total trial duration was recorded using an eye-tracking device. The proportion of trials with adequate ventilation (expiratory tidal volume [VTe], 4-10 mL/kg; peak inspiratory pressure <30 cm H<sub>2</sub>O; leak <40 %) was determined. After excluding incomplete data, 63 simulations (22 participants) were analysed. The ratios of the gaze duration on the manikin to the total trial duration were significantly different among settings A (0.60 [95 % confidence interval: 0.52-0.67] sec/sec), B (0.51 [0.43-0.59] sec/sec), and C (0.80 [0.76-0.84] sec/sec). Ventilation with adequate VTe and less leakage was more frequent in settings A and B than in setting C (adequate VTe: A, 91 %; B, 91 %; and C, 83 %; less leak: A, 76 %; B, 78 %; and C, 57 %).</p><p><strong>Conclusions: </strong>An indicator light close to the facemask with an RFM directed the eyesight towards the manikin without compromising the ventilation quality during the simulation of neonatal resuscitation.</p>\",\"PeriodicalId\":16704,\"journal\":{\"name\":\"Journal of Perinatal Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Perinatal Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/jpm-2024-0251\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Perinatal Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/jpm-2024-0251","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
Effects of a respiratory function indicator light on visual attention and ventilation quality during neonatal resuscitation: a randomised controlled crossover simulation trial.
Objectives: To investigate the effectiveness of placing an indicator light indicating inadequate ventilation near the face mask during positive-pressure ventilation with respiratory function monitors (RFMs) in neonatal resuscitation. The study is a three-group, randomised, controlled, crossover simulation trial.
Methods: Paediatrics residents, neonatology fellows, and attending neonatologists at a single neonatal intensive care unit. A ventilation simulation with a manikin was performed three times consecutively using the same scenario with three different ventilation evaluation methods (A) RFM plus indicator light and conventional methods (heart rate and chest rise) (B) RFM and conventional methods, and (C) conventional methods alone.
Results: The ratio of gaze duration on the manikin to the total trial duration was recorded using an eye-tracking device. The proportion of trials with adequate ventilation (expiratory tidal volume [VTe], 4-10 mL/kg; peak inspiratory pressure <30 cm H2O; leak <40 %) was determined. After excluding incomplete data, 63 simulations (22 participants) were analysed. The ratios of the gaze duration on the manikin to the total trial duration were significantly different among settings A (0.60 [95 % confidence interval: 0.52-0.67] sec/sec), B (0.51 [0.43-0.59] sec/sec), and C (0.80 [0.76-0.84] sec/sec). Ventilation with adequate VTe and less leakage was more frequent in settings A and B than in setting C (adequate VTe: A, 91 %; B, 91 %; and C, 83 %; less leak: A, 76 %; B, 78 %; and C, 57 %).
Conclusions: An indicator light close to the facemask with an RFM directed the eyesight towards the manikin without compromising the ventilation quality during the simulation of neonatal resuscitation.
期刊介绍:
The Journal of Perinatal Medicine (JPM) is a truly international forum covering the entire field of perinatal medicine. It is an essential news source for all those obstetricians, neonatologists, perinatologists and allied health professionals who wish to keep abreast of progress in perinatal and related research. Ahead-of-print publishing ensures fastest possible knowledge transfer. The Journal provides statements on themes of topical interest as well as information and different views on controversial topics. It also informs about the academic, organisational and political aims and objectives of the World Association of Perinatal Medicine.