{"title":"用于直接和灵敏耐甲氧西林金黄色葡萄球菌(MRSA)分析的滚动圈扩增合作 crRNA 开关。","authors":"Junling Qiu, Chang Liu, Yuxia Zhu","doi":"10.1007/s10529-024-03550-8","DOIUrl":null,"url":null,"abstract":"<p><p>Evaluating the methicillin resistance of Staphylococcus aureus (S. aureus) is highly important for adapting nursing strategies. Nevertheless, the identification of methicillin-resistant S. aureus (MRSA) that is both sensitive and reliable continues to pose a significant obstacle. This study describes a method for detecting MRSA using a combination of fixed rolling circle amplification (RCA) and the exonuclease-iii (Exo-iii) assisted CRISPR-Cas12a system for signal amplification. When MRSA is present, the interaction between the \"b\" chain in the capture probe and MRSA allows the \"a\" chain to be exposed. This \"a\" chain acts as a primer to initiate the fixed RCA process. The H probe, which includes the crRNA segment, forms a bond with the RCA product and then releases the crRNA segment with the aid of Exo-iii. The Cas12a protein, when combined with the crRNA, generates an activated CRISPR-Cas12a system that cleaves the \"Reporter\" probe, resulting in the production of fluorescent signals. Furthermore, this fluorescent test has been utilized for the examination of clinical samples with a satisfactory rate of retrieval. Based on the elegant design, the proposed method exhibited a low detection limit of 4.6 cfu/mL, while maintaining a high specificity for MRSA even from a mixture of several interfering bacteria. Due to its cost-effectiveness, simplicity, and adaptability, the sensing system shows potential as a platform for detecting MRSA and evaluating postoperative nursing for stomach cancer patients.</p>","PeriodicalId":8929,"journal":{"name":"Biotechnology Letters","volume":"47 1","pages":"4"},"PeriodicalIF":2.0000,"publicationDate":"2024-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rolling circle amplification cooperating crRNA switch for direct and sensitive methicillin-resistant Staphylococcus aureus (MRSA) analysis.\",\"authors\":\"Junling Qiu, Chang Liu, Yuxia Zhu\",\"doi\":\"10.1007/s10529-024-03550-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Evaluating the methicillin resistance of Staphylococcus aureus (S. aureus) is highly important for adapting nursing strategies. Nevertheless, the identification of methicillin-resistant S. aureus (MRSA) that is both sensitive and reliable continues to pose a significant obstacle. This study describes a method for detecting MRSA using a combination of fixed rolling circle amplification (RCA) and the exonuclease-iii (Exo-iii) assisted CRISPR-Cas12a system for signal amplification. When MRSA is present, the interaction between the \\\"b\\\" chain in the capture probe and MRSA allows the \\\"a\\\" chain to be exposed. This \\\"a\\\" chain acts as a primer to initiate the fixed RCA process. The H probe, which includes the crRNA segment, forms a bond with the RCA product and then releases the crRNA segment with the aid of Exo-iii. The Cas12a protein, when combined with the crRNA, generates an activated CRISPR-Cas12a system that cleaves the \\\"Reporter\\\" probe, resulting in the production of fluorescent signals. Furthermore, this fluorescent test has been utilized for the examination of clinical samples with a satisfactory rate of retrieval. Based on the elegant design, the proposed method exhibited a low detection limit of 4.6 cfu/mL, while maintaining a high specificity for MRSA even from a mixture of several interfering bacteria. Due to its cost-effectiveness, simplicity, and adaptability, the sensing system shows potential as a platform for detecting MRSA and evaluating postoperative nursing for stomach cancer patients.</p>\",\"PeriodicalId\":8929,\"journal\":{\"name\":\"Biotechnology Letters\",\"volume\":\"47 1\",\"pages\":\"4\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotechnology Letters\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10529-024-03550-8\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotechnology Letters","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10529-024-03550-8","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
Rolling circle amplification cooperating crRNA switch for direct and sensitive methicillin-resistant Staphylococcus aureus (MRSA) analysis.
Evaluating the methicillin resistance of Staphylococcus aureus (S. aureus) is highly important for adapting nursing strategies. Nevertheless, the identification of methicillin-resistant S. aureus (MRSA) that is both sensitive and reliable continues to pose a significant obstacle. This study describes a method for detecting MRSA using a combination of fixed rolling circle amplification (RCA) and the exonuclease-iii (Exo-iii) assisted CRISPR-Cas12a system for signal amplification. When MRSA is present, the interaction between the "b" chain in the capture probe and MRSA allows the "a" chain to be exposed. This "a" chain acts as a primer to initiate the fixed RCA process. The H probe, which includes the crRNA segment, forms a bond with the RCA product and then releases the crRNA segment with the aid of Exo-iii. The Cas12a protein, when combined with the crRNA, generates an activated CRISPR-Cas12a system that cleaves the "Reporter" probe, resulting in the production of fluorescent signals. Furthermore, this fluorescent test has been utilized for the examination of clinical samples with a satisfactory rate of retrieval. Based on the elegant design, the proposed method exhibited a low detection limit of 4.6 cfu/mL, while maintaining a high specificity for MRSA even from a mixture of several interfering bacteria. Due to its cost-effectiveness, simplicity, and adaptability, the sensing system shows potential as a platform for detecting MRSA and evaluating postoperative nursing for stomach cancer patients.
期刊介绍:
Biotechnology Letters is the world’s leading rapid-publication primary journal dedicated to biotechnology as a whole – that is to topics relating to actual or potential applications of biological reactions affected by microbial, plant or animal cells and biocatalysts derived from them.
All relevant aspects of molecular biology, genetics and cell biochemistry, of process and reactor design, of pre- and post-treatment steps, and of manufacturing or service operations are therefore included.
Contributions from industrial and academic laboratories are equally welcome. We also welcome contributions covering biotechnological aspects of regenerative medicine and biomaterials and also cancer biotechnology. Criteria for the acceptance of papers relate to our aim of publishing useful and informative results that will be of value to other workers in related fields.
The emphasis is very much on novelty and immediacy in order to justify rapid publication of authors’ results. It should be noted, however, that we do not normally publish papers (but this is not absolute) that deal with unidentified consortia of microorganisms (e.g. as in activated sludge) as these results may not be easily reproducible in other laboratories.
Papers describing the isolation and identification of microorganisms are not regarded as appropriate but such information can be appended as supporting information to a paper. Papers dealing with simple process development are usually considered to lack sufficient novelty or interest to warrant publication.