基于电容式电压互感器测量数据的谐波电压相位重构和谐波状态估计

IF 1.5 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Xiaoxian Zhu, Qingjun Peng, Dexu Zou, Shan Wang, Haozhou Wang, Fangrong Zhou, Desheng Chu
{"title":"基于电容式电压互感器测量数据的谐波电压相位重构和谐波状态估计","authors":"Xiaoxian Zhu,&nbsp;Qingjun Peng,&nbsp;Dexu Zou,&nbsp;Shan Wang,&nbsp;Haozhou Wang,&nbsp;Fangrong Zhou,&nbsp;Desheng Chu","doi":"10.1049/elp2.12481","DOIUrl":null,"url":null,"abstract":"<p>Harmonic state estimation, which highly depends on accurate synchronised phasors, is a crucial basis for the location, traceability, and governance of harmonics in power systems. However, most existing synchronous phasor measurement units (PMUs) provide power frequency phasors rather than harmonic phasors. In addition, as the dominant voltage signal provider for PMUs in power systems, capacitive voltage transformers (CVTs) have complex frequency responses and cannot be directly used for harmonic measurement. Therefore, accurate harmonic state estimation is difficult to achieve in applications. A method for harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a CVT is proposed. First, the reasons for harmonic voltage measurement errors were analysed. Second, the scattering parameter method was used to measure the wideband voltage transfer characteristics of CVT. Third, a voltage reconstruction method was proposed to improve the measurement accuracy and expand the frequency range of synchronous phasor measurement. Fourth, this method was applied to harmonic state estimation, and the performance of harmonic state estimation before and after voltage reconstruction was quantitatively compared. Results showed that the proposed method can remarkably improve the accuracy of harmonic state estimation. Finally, some factors, such as state observability, complex error disturbances, CVT structure, and harmonic order, influencing the performance of the proposed method were investigated. Results further demonstrated that the method has high accuracy, strong anti-interference, and adaptability, and can provide basic information for harmonic localisation and traceability.</p>","PeriodicalId":13352,"journal":{"name":"Iet Electric Power Applications","volume":"18 10","pages":"1332-1346"},"PeriodicalIF":1.5000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/elp2.12481","citationCount":"0","resultStr":"{\"title\":\"Harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a capacitive voltage transformer\",\"authors\":\"Xiaoxian Zhu,&nbsp;Qingjun Peng,&nbsp;Dexu Zou,&nbsp;Shan Wang,&nbsp;Haozhou Wang,&nbsp;Fangrong Zhou,&nbsp;Desheng Chu\",\"doi\":\"10.1049/elp2.12481\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Harmonic state estimation, which highly depends on accurate synchronised phasors, is a crucial basis for the location, traceability, and governance of harmonics in power systems. However, most existing synchronous phasor measurement units (PMUs) provide power frequency phasors rather than harmonic phasors. In addition, as the dominant voltage signal provider for PMUs in power systems, capacitive voltage transformers (CVTs) have complex frequency responses and cannot be directly used for harmonic measurement. Therefore, accurate harmonic state estimation is difficult to achieve in applications. A method for harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a CVT is proposed. First, the reasons for harmonic voltage measurement errors were analysed. Second, the scattering parameter method was used to measure the wideband voltage transfer characteristics of CVT. Third, a voltage reconstruction method was proposed to improve the measurement accuracy and expand the frequency range of synchronous phasor measurement. Fourth, this method was applied to harmonic state estimation, and the performance of harmonic state estimation before and after voltage reconstruction was quantitatively compared. Results showed that the proposed method can remarkably improve the accuracy of harmonic state estimation. Finally, some factors, such as state observability, complex error disturbances, CVT structure, and harmonic order, influencing the performance of the proposed method were investigated. Results further demonstrated that the method has high accuracy, strong anti-interference, and adaptability, and can provide basic information for harmonic localisation and traceability.</p>\",\"PeriodicalId\":13352,\"journal\":{\"name\":\"Iet Electric Power Applications\",\"volume\":\"18 10\",\"pages\":\"1332-1346\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/elp2.12481\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iet Electric Power Applications\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/elp2.12481\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Electric Power Applications","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/elp2.12481","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

谐波状态估计高度依赖于精确的同步相位,是电力系统谐波定位、可追溯性和治理的重要基础。然而,现有的大多数同步相位测量单元(PMU)提供的是工频相位,而不是谐波相位。此外,作为电力系统 PMU 的主要电压信号提供者,电容式电压互感器 (CVT) 具有复杂的频率响应,不能直接用于谐波测量。因此,在应用中很难实现精确的谐波状态估计。本文提出了一种基于 CVT 测量数据的谐波电压相位重构和谐波状态估计方法。首先,分析了谐波电压测量误差的原因。其次,使用散射参数法测量无级变速器的宽带电压传递特性。第三,提出了一种电压重构方法,以提高测量精度并扩大同步相量测量的频率范围。第四,将该方法应用于谐波状态估计,并定量比较了电压重构前后谐波状态估计的性能。结果表明,所提出的方法能显著提高谐波状态估计的准确性。最后,研究了影响所提方法性能的一些因素,如状态可观测性、复杂误差干扰、无级变速器结构和谐波阶次。结果进一步证明,该方法具有精度高、抗干扰性强、适应性强等特点,可为谐波定位和溯源提供基本信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a capacitive voltage transformer

Harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a capacitive voltage transformer

Harmonic state estimation, which highly depends on accurate synchronised phasors, is a crucial basis for the location, traceability, and governance of harmonics in power systems. However, most existing synchronous phasor measurement units (PMUs) provide power frequency phasors rather than harmonic phasors. In addition, as the dominant voltage signal provider for PMUs in power systems, capacitive voltage transformers (CVTs) have complex frequency responses and cannot be directly used for harmonic measurement. Therefore, accurate harmonic state estimation is difficult to achieve in applications. A method for harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a CVT is proposed. First, the reasons for harmonic voltage measurement errors were analysed. Second, the scattering parameter method was used to measure the wideband voltage transfer characteristics of CVT. Third, a voltage reconstruction method was proposed to improve the measurement accuracy and expand the frequency range of synchronous phasor measurement. Fourth, this method was applied to harmonic state estimation, and the performance of harmonic state estimation before and after voltage reconstruction was quantitatively compared. Results showed that the proposed method can remarkably improve the accuracy of harmonic state estimation. Finally, some factors, such as state observability, complex error disturbances, CVT structure, and harmonic order, influencing the performance of the proposed method were investigated. Results further demonstrated that the method has high accuracy, strong anti-interference, and adaptability, and can provide basic information for harmonic localisation and traceability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iet Electric Power Applications
Iet Electric Power Applications 工程技术-工程:电子与电气
CiteScore
4.80
自引率
5.90%
发文量
104
审稿时长
3 months
期刊介绍: IET Electric Power Applications publishes papers of a high technical standard with a suitable balance of practice and theory. The scope covers a wide range of applications and apparatus in the power field. In addition to papers focussing on the design and development of electrical equipment, papers relying on analysis are also sought, provided that the arguments are conveyed succinctly and the conclusions are clear. The scope of the journal includes the following: The design and analysis of motors and generators of all sizes Rotating electrical machines Linear machines Actuators Power transformers Railway traction machines and drives Variable speed drives Machines and drives for electrically powered vehicles Industrial and non-industrial applications and processes Current Special Issue. Call for papers: Progress in Electric Machines, Power Converters and their Control for Wave Energy Generation - https://digital-library.theiet.org/files/IET_EPA_CFP_PEMPCCWEG.pdf
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信