{"title":"CO₂ 跨临界分布式压缩制冷循环中的最佳中间压力研究","authors":"Junrui Nie, Guoyuan Ma, Lei Wang","doi":"10.1016/j.ijrefrig.2024.11.014","DOIUrl":null,"url":null,"abstract":"<div><div>The CO<sub>2</sub> transcritical distributed compression cycle proposal provides a novel approach for refrigerant cooling in traditional transcritical cycles. This paper employed an exhaustive search method to derive the correlation formula for the optimal intermediate pressure. From the perspectives of thermodynamic performance and economics, a comparative analysis was conducted between the cycle established under the optimal intermediate pressure obtained in this study, the cycle based on equal compression ratios in traditional two-stage compression cycles, and the cycle established using the optimal secondary compression ratio method based on low-pressure stage discharge pressure mentioned in previous literature study. The research results indicate that the system's COP calculated using the obtained optimal intermediate pressure correlation method can be improved by up to 7.26% and 5.32%, respectively, compared to the traditional and literature-based methods. The exergy loss with the optimal intermediate pressure method is less than with the other two methods. The entransy dissipation rate of the system obtained using the optimal intermediate pressure correlation method is 24.61% and 50.14% lower than that of the traditional and literature-based methods, respectively. The investment cost of the main components using the optimal intermediate pressure correlation method is about 5% higher than that of the traditional method and about 1% higher than that of the optimal pressure ratio method. However, the total annual cost rate of the system is the lowest. The research enriches and improves the theory of the CO₂ transcritical distributed compression cycle, thereby facilitating the advancement of practical applications based on this cycle theory.</div></div>","PeriodicalId":14274,"journal":{"name":"International Journal of Refrigeration-revue Internationale Du Froid","volume":"169 ","pages":"Pages 405-417"},"PeriodicalIF":3.5000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimal Intermediate Pressure Investigation in a CO₂ Transcritical Distributed Compression Refrigeration Cycle\",\"authors\":\"Junrui Nie, Guoyuan Ma, Lei Wang\",\"doi\":\"10.1016/j.ijrefrig.2024.11.014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The CO<sub>2</sub> transcritical distributed compression cycle proposal provides a novel approach for refrigerant cooling in traditional transcritical cycles. This paper employed an exhaustive search method to derive the correlation formula for the optimal intermediate pressure. From the perspectives of thermodynamic performance and economics, a comparative analysis was conducted between the cycle established under the optimal intermediate pressure obtained in this study, the cycle based on equal compression ratios in traditional two-stage compression cycles, and the cycle established using the optimal secondary compression ratio method based on low-pressure stage discharge pressure mentioned in previous literature study. The research results indicate that the system's COP calculated using the obtained optimal intermediate pressure correlation method can be improved by up to 7.26% and 5.32%, respectively, compared to the traditional and literature-based methods. The exergy loss with the optimal intermediate pressure method is less than with the other two methods. The entransy dissipation rate of the system obtained using the optimal intermediate pressure correlation method is 24.61% and 50.14% lower than that of the traditional and literature-based methods, respectively. The investment cost of the main components using the optimal intermediate pressure correlation method is about 5% higher than that of the traditional method and about 1% higher than that of the optimal pressure ratio method. However, the total annual cost rate of the system is the lowest. The research enriches and improves the theory of the CO₂ transcritical distributed compression cycle, thereby facilitating the advancement of practical applications based on this cycle theory.</div></div>\",\"PeriodicalId\":14274,\"journal\":{\"name\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"volume\":\"169 \",\"pages\":\"Pages 405-417\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0140700724003992\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Refrigeration-revue Internationale Du Froid","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0140700724003992","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Optimal Intermediate Pressure Investigation in a CO₂ Transcritical Distributed Compression Refrigeration Cycle
The CO2 transcritical distributed compression cycle proposal provides a novel approach for refrigerant cooling in traditional transcritical cycles. This paper employed an exhaustive search method to derive the correlation formula for the optimal intermediate pressure. From the perspectives of thermodynamic performance and economics, a comparative analysis was conducted between the cycle established under the optimal intermediate pressure obtained in this study, the cycle based on equal compression ratios in traditional two-stage compression cycles, and the cycle established using the optimal secondary compression ratio method based on low-pressure stage discharge pressure mentioned in previous literature study. The research results indicate that the system's COP calculated using the obtained optimal intermediate pressure correlation method can be improved by up to 7.26% and 5.32%, respectively, compared to the traditional and literature-based methods. The exergy loss with the optimal intermediate pressure method is less than with the other two methods. The entransy dissipation rate of the system obtained using the optimal intermediate pressure correlation method is 24.61% and 50.14% lower than that of the traditional and literature-based methods, respectively. The investment cost of the main components using the optimal intermediate pressure correlation method is about 5% higher than that of the traditional method and about 1% higher than that of the optimal pressure ratio method. However, the total annual cost rate of the system is the lowest. The research enriches and improves the theory of the CO₂ transcritical distributed compression cycle, thereby facilitating the advancement of practical applications based on this cycle theory.
期刊介绍:
The International Journal of Refrigeration is published for the International Institute of Refrigeration (IIR) by Elsevier. It is essential reading for all those wishing to keep abreast of research and industrial news in refrigeration, air conditioning and associated fields. This is particularly important in these times of rapid introduction of alternative refrigerants and the emergence of new technology. The journal has published special issues on alternative refrigerants and novel topics in the field of boiling, condensation, heat pumps, food refrigeration, carbon dioxide, ammonia, hydrocarbons, magnetic refrigeration at room temperature, sorptive cooling, phase change materials and slurries, ejector technology, compressors, and solar cooling.
As well as original research papers the International Journal of Refrigeration also includes review articles, papers presented at IIR conferences, short reports and letters describing preliminary results and experimental details, and letters to the Editor on recent areas of discussion and controversy. Other features include forthcoming events, conference reports and book reviews.
Papers are published in either English or French with the IIR news section in both languages.