[最佳激光碎石模式是否最佳?]

Q4 Medicine
Urologiia Pub Date : 2024-07-01
A Lee Y, M Dymov A, H Ali S, A Chislov P, Y Mikhailov V, V Lobanov M, N Akopyan G, V Chinenov D, A Gazimiyev M, Z Vinarov A
{"title":"[最佳激光碎石模式是否最佳?]","authors":"A Lee Y, M Dymov A, H Ali S, A Chislov P, Y Mikhailov V, V Lobanov M, N Akopyan G, V Chinenov D, A Gazimiyev M, Z Vinarov A","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>to evaluate the effectiveness of the recommended modes of laser lithotripsy in clinical practice by analyzing the necessity of changing laser radiation parameters during percutaneous nephrolithotripsy (PCNL), ureterolithotripsy (URS) and retrograde intrarenal surgery (RIRS).</p><p><strong>Materials and methods: </strong>a prospective non-randomized clinical study was conducted from October 2023 to December 2023. Patients who underwent surgical procedures for urinary stones using a Thulium fiber laser at the Clinic of Urology of Sechenov University were included. Data on localization, size and radiological density of the stones, initial parameters of laser radiation, presence or absence of mode change were recorded. Statistical data was processed using IBM SPSS Statistics software, version 26.0.0.0.0.</p><p><strong>Results: </strong>90 patients were included in the study. Laser radiation mode change was recorded in 38% of cases when performing RIRS, in 25% - during PCNL, and in 24% - during URS. A significantly higher total energy consumption at comparable volumes and radiological density of the stones was registered in the group of mode change at RIRS. In the URS group the results suggest that the laser radiation mode change depends on the volume and density of urinary stones.</p><p><strong>Discussion: </strong>the need for intraoperative change of laser radiation modes in 31% of all observations may indicate that the existing optimal modes for stone destruction in clinical practice may be suboptimal. New studies of the structure and mechanical properties of urinary stones, assessment of their porosity, hardness, size and properties of crystals, as well as the use of Artificial Intelligence for automatic set up of laser radiation parameters for higher efficiency of lithotripsy.</p><p><strong>Conclusion: </strong>In addition to linear size and radiologic density urinary stones have a whole complex of morphometric and physicochemical characteristics, so the laser lithotripsy parameters preset should be viewed only as a guideline, while effective settings are to be selected intraoperatively considering urologists knowledge of laser radiation physical properties.</p>","PeriodicalId":23546,"journal":{"name":"Urologiia","volume":" 3","pages":"5-9"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Are Optimal modes of laser lithotripsy optimal?]\",\"authors\":\"A Lee Y, M Dymov A, H Ali S, A Chislov P, Y Mikhailov V, V Lobanov M, N Akopyan G, V Chinenov D, A Gazimiyev M, Z Vinarov A\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>to evaluate the effectiveness of the recommended modes of laser lithotripsy in clinical practice by analyzing the necessity of changing laser radiation parameters during percutaneous nephrolithotripsy (PCNL), ureterolithotripsy (URS) and retrograde intrarenal surgery (RIRS).</p><p><strong>Materials and methods: </strong>a prospective non-randomized clinical study was conducted from October 2023 to December 2023. Patients who underwent surgical procedures for urinary stones using a Thulium fiber laser at the Clinic of Urology of Sechenov University were included. Data on localization, size and radiological density of the stones, initial parameters of laser radiation, presence or absence of mode change were recorded. Statistical data was processed using IBM SPSS Statistics software, version 26.0.0.0.0.</p><p><strong>Results: </strong>90 patients were included in the study. Laser radiation mode change was recorded in 38% of cases when performing RIRS, in 25% - during PCNL, and in 24% - during URS. A significantly higher total energy consumption at comparable volumes and radiological density of the stones was registered in the group of mode change at RIRS. In the URS group the results suggest that the laser radiation mode change depends on the volume and density of urinary stones.</p><p><strong>Discussion: </strong>the need for intraoperative change of laser radiation modes in 31% of all observations may indicate that the existing optimal modes for stone destruction in clinical practice may be suboptimal. New studies of the structure and mechanical properties of urinary stones, assessment of their porosity, hardness, size and properties of crystals, as well as the use of Artificial Intelligence for automatic set up of laser radiation parameters for higher efficiency of lithotripsy.</p><p><strong>Conclusion: </strong>In addition to linear size and radiologic density urinary stones have a whole complex of morphometric and physicochemical characteristics, so the laser lithotripsy parameters preset should be viewed only as a guideline, while effective settings are to be selected intraoperatively considering urologists knowledge of laser radiation physical properties.</p>\",\"PeriodicalId\":23546,\"journal\":{\"name\":\"Urologiia\",\"volume\":\" 3\",\"pages\":\"5-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Urologiia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urologiia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:通过分析经皮肾镜碎石术(PCNL)、输尿管碎石术(URS)和逆行肾内手术(RIRS)期间改变激光辐射参数的必要性,评估推荐的激光碎石模式在临床实践中的有效性。研究对象包括在谢切诺夫大学泌尿外科诊所接受铥光纤激光手术治疗尿路结石的患者。记录了结石的定位、大小和放射学密度、激光辐射的初始参数、有无模式变化等数据。统计数据使用 IBM SPSS 统计软件 26.0.0.0 版进行处理:研究共纳入 90 名患者。在进行 RIRS 时,有 38% 的病例记录到激光辐射模式改变,在 PCNL 时有 25% 的病例记录到,在 URS 时有 24% 的病例记录到。在进行 RIRS 时改变模式的组别中,在结石体积和放射学密度相当的情况下,总能量消耗明显更高。在 URS 组中,结果表明激光辐射模式的改变取决于尿路结石的体积和密度。讨论:在所有观察结果中,有 31% 的人需要在术中改变激光辐射模式,这可能表明临床实践中现有的最佳碎石模式可能并不理想。对泌尿系结石的结构和机械特性进行新的研究,评估结石的孔隙率、硬度、晶体的大小和特性,以及利用人工智能自动设置激光辐射参数,以提高碎石效率:结论:泌尿系结石除了线性大小和放射学密度外,还具有一整套复杂的形态和物理化学特征,因此激光碎石参数预设应仅被视为一种指导,而有效的设置则应根据泌尿科医生对激光辐射物理特性的了解在术中进行选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Are Optimal modes of laser lithotripsy optimal?]

Objective: to evaluate the effectiveness of the recommended modes of laser lithotripsy in clinical practice by analyzing the necessity of changing laser radiation parameters during percutaneous nephrolithotripsy (PCNL), ureterolithotripsy (URS) and retrograde intrarenal surgery (RIRS).

Materials and methods: a prospective non-randomized clinical study was conducted from October 2023 to December 2023. Patients who underwent surgical procedures for urinary stones using a Thulium fiber laser at the Clinic of Urology of Sechenov University were included. Data on localization, size and radiological density of the stones, initial parameters of laser radiation, presence or absence of mode change were recorded. Statistical data was processed using IBM SPSS Statistics software, version 26.0.0.0.0.

Results: 90 patients were included in the study. Laser radiation mode change was recorded in 38% of cases when performing RIRS, in 25% - during PCNL, and in 24% - during URS. A significantly higher total energy consumption at comparable volumes and radiological density of the stones was registered in the group of mode change at RIRS. In the URS group the results suggest that the laser radiation mode change depends on the volume and density of urinary stones.

Discussion: the need for intraoperative change of laser radiation modes in 31% of all observations may indicate that the existing optimal modes for stone destruction in clinical practice may be suboptimal. New studies of the structure and mechanical properties of urinary stones, assessment of their porosity, hardness, size and properties of crystals, as well as the use of Artificial Intelligence for automatic set up of laser radiation parameters for higher efficiency of lithotripsy.

Conclusion: In addition to linear size and radiologic density urinary stones have a whole complex of morphometric and physicochemical characteristics, so the laser lithotripsy parameters preset should be viewed only as a guideline, while effective settings are to be selected intraoperatively considering urologists knowledge of laser radiation physical properties.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Urologiia
Urologiia Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
160
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信