基于梯度下降优化的逆变器电能质量管理

IF 1.9 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Changbin Hu, Haiyang Huang, Sai Zhang, Linshu Cheng, Shanna Luo, Gaowei Wang
{"title":"基于梯度下降优化的逆变器电能质量管理","authors":"Changbin Hu,&nbsp;Haiyang Huang,&nbsp;Sai Zhang,&nbsp;Linshu Cheng,&nbsp;Shanna Luo,&nbsp;Gaowei Wang","doi":"10.1155/etep/1883894","DOIUrl":null,"url":null,"abstract":"<div>\n <p>In isolated microgrids, the dynamic performance of the inverter output voltage is degraded due to the connection of unbalanced and nonlinear load, load switching, and significant perturbation of filter parameters. A compensation control structure based on the residual generator integrated with an optimization algorithm is proposed to improve the power quality of the inverter output voltage in this paper. First, the structure and mathematical model of the inverter are analyzed. The sensitivity results show that the residual generator–based compensating control structure improves the robustness of the inverter compared to the conventional <i>V</i>/<i>f</i> control. Second, a controller structure with lower order is derived with reduced-order theory for easier engineering implementation. Then, the compensation controller parameters are optimized online using the gradient descent optimization algorithm to improve the load disturbance’s dynamic compensation performance and reduce the power quality degradation resulting from parameter perturbation. Finally, the PEK-530 inverter platform developed by GWinstek is utilized for experimental verification. When the inverter is tested with unbalanced loads and nonlinear loads at load switching and with LC filter parameter perturbation, the three-phase unbalance, total harmonic distortion rate, d-axis voltage fluctuation, and total harmonic distortion rate of the inverter output voltage are 3.2%, 5.4%, ±2 V, and 0.5%, respectively, and are further reduced to 0.3%, 2.8%, ±0.2 V, and 0.22%, after the compensation controller is optimized by the gradient descent method. The experimental results show that the proposed improved control strategy can effectively improve the disturbance’s fast compensation performance, robustness to inverter parameter perturbation, and the power quality.</p>\n </div>","PeriodicalId":51293,"journal":{"name":"International Transactions on Electrical Energy Systems","volume":"2024 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/etep/1883894","citationCount":"0","resultStr":"{\"title\":\"Power Quality Management of Inverter Based on Gradient Descent Optimization\",\"authors\":\"Changbin Hu,&nbsp;Haiyang Huang,&nbsp;Sai Zhang,&nbsp;Linshu Cheng,&nbsp;Shanna Luo,&nbsp;Gaowei Wang\",\"doi\":\"10.1155/etep/1883894\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n <p>In isolated microgrids, the dynamic performance of the inverter output voltage is degraded due to the connection of unbalanced and nonlinear load, load switching, and significant perturbation of filter parameters. A compensation control structure based on the residual generator integrated with an optimization algorithm is proposed to improve the power quality of the inverter output voltage in this paper. First, the structure and mathematical model of the inverter are analyzed. The sensitivity results show that the residual generator–based compensating control structure improves the robustness of the inverter compared to the conventional <i>V</i>/<i>f</i> control. Second, a controller structure with lower order is derived with reduced-order theory for easier engineering implementation. Then, the compensation controller parameters are optimized online using the gradient descent optimization algorithm to improve the load disturbance’s dynamic compensation performance and reduce the power quality degradation resulting from parameter perturbation. Finally, the PEK-530 inverter platform developed by GWinstek is utilized for experimental verification. When the inverter is tested with unbalanced loads and nonlinear loads at load switching and with LC filter parameter perturbation, the three-phase unbalance, total harmonic distortion rate, d-axis voltage fluctuation, and total harmonic distortion rate of the inverter output voltage are 3.2%, 5.4%, ±2 V, and 0.5%, respectively, and are further reduced to 0.3%, 2.8%, ±0.2 V, and 0.22%, after the compensation controller is optimized by the gradient descent method. The experimental results show that the proposed improved control strategy can effectively improve the disturbance’s fast compensation performance, robustness to inverter parameter perturbation, and the power quality.</p>\\n </div>\",\"PeriodicalId\":51293,\"journal\":{\"name\":\"International Transactions on Electrical Energy Systems\",\"volume\":\"2024 1\",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1155/etep/1883894\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Transactions on Electrical Energy Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1155/etep/1883894\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Transactions on Electrical Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/etep/1883894","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

在孤立微电网中,由于连接不平衡和非线性负载、负载切换以及滤波器参数的显著扰动,逆变器输出电压的动态性能会下降。本文提出了一种基于剩余发电机的补偿控制结构,并集成了优化算法,以改善逆变器输出电压的电能质量。首先,分析了逆变器的结构和数学模型。灵敏度结果表明,与传统的 V/f 控制相比,基于残差发电机的补偿控制结构提高了逆变器的鲁棒性。其次,利用减阶理论推导出了一种阶数更低的控制器结构,以方便工程实施。然后,利用梯度下降优化算法对补偿控制器参数进行在线优化,以提高负载扰动的动态补偿性能,减少参数扰动导致的电能质量下降。最后,利用 GWinstek 开发的 PEK-530 逆变器平台进行实验验证。当逆变器在负载切换时带不平衡负载和非线性负载,并在 LC 滤波器参数扰动的情况下进行测试时,逆变器输出电压的三相不平衡度、总谐波畸变率、d 轴电压波动和总谐波畸变率分别为 3.2%、5.4%、±2 V 和 0.5%,在采用梯度下降法优化补偿控制器后,进一步降至 0.3%、2.8%、±0.2 V 和 0.22%。实验结果表明,所提出的改进控制策略能有效改善扰动的快速补偿性能、对逆变器参数扰动的鲁棒性以及电能质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Power Quality Management of Inverter Based on Gradient Descent Optimization

Power Quality Management of Inverter Based on Gradient Descent Optimization

In isolated microgrids, the dynamic performance of the inverter output voltage is degraded due to the connection of unbalanced and nonlinear load, load switching, and significant perturbation of filter parameters. A compensation control structure based on the residual generator integrated with an optimization algorithm is proposed to improve the power quality of the inverter output voltage in this paper. First, the structure and mathematical model of the inverter are analyzed. The sensitivity results show that the residual generator–based compensating control structure improves the robustness of the inverter compared to the conventional V/f control. Second, a controller structure with lower order is derived with reduced-order theory for easier engineering implementation. Then, the compensation controller parameters are optimized online using the gradient descent optimization algorithm to improve the load disturbance’s dynamic compensation performance and reduce the power quality degradation resulting from parameter perturbation. Finally, the PEK-530 inverter platform developed by GWinstek is utilized for experimental verification. When the inverter is tested with unbalanced loads and nonlinear loads at load switching and with LC filter parameter perturbation, the three-phase unbalance, total harmonic distortion rate, d-axis voltage fluctuation, and total harmonic distortion rate of the inverter output voltage are 3.2%, 5.4%, ±2 V, and 0.5%, respectively, and are further reduced to 0.3%, 2.8%, ±0.2 V, and 0.22%, after the compensation controller is optimized by the gradient descent method. The experimental results show that the proposed improved control strategy can effectively improve the disturbance’s fast compensation performance, robustness to inverter parameter perturbation, and the power quality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Transactions on Electrical Energy Systems
International Transactions on Electrical Energy Systems ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
6.70
自引率
8.70%
发文量
342
期刊介绍: International Transactions on Electrical Energy Systems publishes original research results on key advances in the generation, transmission, and distribution of electrical energy systems. Of particular interest are submissions concerning the modeling, analysis, optimization and control of advanced electric power systems. Manuscripts on topics of economics, finance, policies, insulation materials, low-voltage power electronics, plasmas, and magnetics will generally not be considered for review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信