用于高性能电化学比率定量 miR-21-5p† 的机械稳定 UiO-66-NH2-MB 丝网印刷碳电极

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Analyst Pub Date : 2024-11-20 DOI:10.1039/d4an01302f
Jianjing Shen, Li Yan, Jun Pang, Zhenyu Chu, Ying Xie, Shan Huang, Xiaojun Chen
{"title":"用于高性能电化学比率定量 miR-21-5p† 的机械稳定 UiO-66-NH2-MB 丝网印刷碳电极","authors":"Jianjing Shen, Li Yan, Jun Pang, Zhenyu Chu, Ying Xie, Shan Huang, Xiaojun Chen","doi":"10.1039/d4an01302f","DOIUrl":null,"url":null,"abstract":"The ratiometric sensing strategy with dual-signal output drastically compensates for the background noise and interference from the detection environment of the sensing method with a single-signal output. However, the stability of the reference signal has become the primary challenge in constructing a ratio detection sensor. Therefore, in order to realize stable ratio signal sensing detection, methylene blue (MB) was encapsulated in the UiO-66-NH2 framework and printed as a reference signal inside a screen printed carbon electrodes (SPCE), which was helpful for the precise detection of miR-21-5p. Subsequently, based on the ultra-sensitive detection mechanism of catalytic hairpin assembly (CHA), the combination of miR-21-5p with H1 sequence on the Au-deposited SPCE triggered the loop-open of H1. After that, ferrocene labeled H2 (H2-Fc) and H3-Fc sequences were sequentially added to form a stable “T-shaped” structure, and miR-21-5p was released into the next cycle. Thus, the detection of miR-21-5p was quantified by the current ratio of Fc with MB, obtaining a ultra-low detection limit of 2.7 fM. This ratiometric sensing strategy based on SPCE offered a promising pathway for the highly sensitive sensing platforms.","PeriodicalId":63,"journal":{"name":"Analyst","volume":"251 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mechanically Stabilized UiO-66-NH2-MB Screen Printed Carbon Electrode for High Performance Electrochemical Ratiometric Quantification of miR-21-5p†\",\"authors\":\"Jianjing Shen, Li Yan, Jun Pang, Zhenyu Chu, Ying Xie, Shan Huang, Xiaojun Chen\",\"doi\":\"10.1039/d4an01302f\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ratiometric sensing strategy with dual-signal output drastically compensates for the background noise and interference from the detection environment of the sensing method with a single-signal output. However, the stability of the reference signal has become the primary challenge in constructing a ratio detection sensor. Therefore, in order to realize stable ratio signal sensing detection, methylene blue (MB) was encapsulated in the UiO-66-NH2 framework and printed as a reference signal inside a screen printed carbon electrodes (SPCE), which was helpful for the precise detection of miR-21-5p. Subsequently, based on the ultra-sensitive detection mechanism of catalytic hairpin assembly (CHA), the combination of miR-21-5p with H1 sequence on the Au-deposited SPCE triggered the loop-open of H1. After that, ferrocene labeled H2 (H2-Fc) and H3-Fc sequences were sequentially added to form a stable “T-shaped” structure, and miR-21-5p was released into the next cycle. Thus, the detection of miR-21-5p was quantified by the current ratio of Fc with MB, obtaining a ultra-low detection limit of 2.7 fM. This ratiometric sensing strategy based on SPCE offered a promising pathway for the highly sensitive sensing platforms.\",\"PeriodicalId\":63,\"journal\":{\"name\":\"Analyst\",\"volume\":\"251 1\",\"pages\":\"\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2024-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analyst\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1039/d4an01302f\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4an01302f","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

双信号输出的比率检测策略极大地补偿了单信号输出检测方法的背景噪声和检测环境干扰。然而,参考信号的稳定性已成为构建比率检测传感器的首要挑战。因此,为了实现稳定的比值信号传感检测,在 UiO-66-NH2 框架中封装了亚甲基蓝(MB),并将其作为参考信号印制在丝网印刷碳电极(SPCE)内,这有助于精确检测 miR-21-5p。随后,基于催化发夹组装(CHA)的超灵敏检测机制,miR-21-5p与H1序列结合在金沉积的SPCE上,触发了H1的开环。随后,二茂铁标记的 H2(H2-Fc)和 H3-Fc 序列依次加入,形成稳定的 "T "形结构,miR-21-5p 被释放到下一个循环中。因此,miR-21-5p 的检测是通过 Fc 与 MB 的电流比进行量化的,从而获得了 2.7 fM 的超低检测限。这种基于 SPCE 的比率测量传感策略为高灵敏度传感平台提供了一种前景广阔的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mechanically Stabilized UiO-66-NH2-MB Screen Printed Carbon Electrode for High Performance Electrochemical Ratiometric Quantification of miR-21-5p†
The ratiometric sensing strategy with dual-signal output drastically compensates for the background noise and interference from the detection environment of the sensing method with a single-signal output. However, the stability of the reference signal has become the primary challenge in constructing a ratio detection sensor. Therefore, in order to realize stable ratio signal sensing detection, methylene blue (MB) was encapsulated in the UiO-66-NH2 framework and printed as a reference signal inside a screen printed carbon electrodes (SPCE), which was helpful for the precise detection of miR-21-5p. Subsequently, based on the ultra-sensitive detection mechanism of catalytic hairpin assembly (CHA), the combination of miR-21-5p with H1 sequence on the Au-deposited SPCE triggered the loop-open of H1. After that, ferrocene labeled H2 (H2-Fc) and H3-Fc sequences were sequentially added to form a stable “T-shaped” structure, and miR-21-5p was released into the next cycle. Thus, the detection of miR-21-5p was quantified by the current ratio of Fc with MB, obtaining a ultra-low detection limit of 2.7 fM. This ratiometric sensing strategy based on SPCE offered a promising pathway for the highly sensitive sensing platforms.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信