基于氧化石墨烯的病原菌检测荧光生物传感器:综述

IF 5.7 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Shiwu Liu, Fangguo Lu, Shanquan Chen, Yi Ning
{"title":"基于氧化石墨烯的病原菌检测荧光生物传感器:综述","authors":"Shiwu Liu, Fangguo Lu, Shanquan Chen, Yi Ning","doi":"10.1016/j.aca.2024.343428","DOIUrl":null,"url":null,"abstract":"<h3>Background</h3>Pathogenic bacteria are widespread in nature and can cause infections and various complications, thereby posing a severe risk to public health. Therefore, simple, rapid, sensitive, and cost-effective methods must be developed to detect pathogenic bacteria. Biosensors are prominent platforms for detecting pathogenic bacteria owing to their high sensitivity, specificity, repeatability, and stability. With the development of nanotechnology, graphene oxide (GO) has been increasingly introduced into the construction of fluorescent biosensors to enhance their performance owing to its unique physicochemical properties.<h3>Results</h3>This review systematically summarizes the development of GO-based fluorescent biosensors for the detection of pathogenic bacteria. First, we introduce the functionalization and modification of GO. The design and signal amplification strategies for GO-based fluorescent biosensors are also discussed. Finally, we explore the challenges and new perspectives associated with this field, with the aim of facilitating the development of GO-based fluorescent sensing technologies to prevent the spread of multidrug-resistant bacteria.<h3>Significance</h3>This review will aid in the development of high-performance biosensors for pathogenic bacterial assays.","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":"10 1","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2024-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Graphene oxide-based fluorescent biosensors for pathogenic bacteria detection: a review\",\"authors\":\"Shiwu Liu, Fangguo Lu, Shanquan Chen, Yi Ning\",\"doi\":\"10.1016/j.aca.2024.343428\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3>Background</h3>Pathogenic bacteria are widespread in nature and can cause infections and various complications, thereby posing a severe risk to public health. Therefore, simple, rapid, sensitive, and cost-effective methods must be developed to detect pathogenic bacteria. Biosensors are prominent platforms for detecting pathogenic bacteria owing to their high sensitivity, specificity, repeatability, and stability. With the development of nanotechnology, graphene oxide (GO) has been increasingly introduced into the construction of fluorescent biosensors to enhance their performance owing to its unique physicochemical properties.<h3>Results</h3>This review systematically summarizes the development of GO-based fluorescent biosensors for the detection of pathogenic bacteria. First, we introduce the functionalization and modification of GO. The design and signal amplification strategies for GO-based fluorescent biosensors are also discussed. Finally, we explore the challenges and new perspectives associated with this field, with the aim of facilitating the development of GO-based fluorescent sensing technologies to prevent the spread of multidrug-resistant bacteria.<h3>Significance</h3>This review will aid in the development of high-performance biosensors for pathogenic bacterial assays.\",\"PeriodicalId\":240,\"journal\":{\"name\":\"Analytica Chimica Acta\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-11-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica Chimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.aca.2024.343428\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.aca.2024.343428","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景致病菌在自然界中广泛存在,可引起感染和各种并发症,从而对公众健康构成严重威胁。因此,必须开发简单、快速、灵敏和经济有效的方法来检测致病细菌。生物传感器因其高灵敏度、特异性、可重复性和稳定性而成为检测致病细菌的重要平台。随着纳米技术的发展,氧化石墨烯(GO)因其独特的物理化学特性被越来越多地引入到荧光生物传感器的构建中,以提高其性能。首先,我们介绍了 GO 的功能化和修饰。还讨论了基于 GO 的荧光生物传感器的设计和信号放大策略。最后,我们探讨了与这一领域相关的挑战和新视角,旨在促进基于 GO 的荧光传感技术的发展,以防止多重耐药细菌的传播。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Graphene oxide-based fluorescent biosensors for pathogenic bacteria detection: a review

Graphene oxide-based fluorescent biosensors for pathogenic bacteria detection: a review

Background

Pathogenic bacteria are widespread in nature and can cause infections and various complications, thereby posing a severe risk to public health. Therefore, simple, rapid, sensitive, and cost-effective methods must be developed to detect pathogenic bacteria. Biosensors are prominent platforms for detecting pathogenic bacteria owing to their high sensitivity, specificity, repeatability, and stability. With the development of nanotechnology, graphene oxide (GO) has been increasingly introduced into the construction of fluorescent biosensors to enhance their performance owing to its unique physicochemical properties.

Results

This review systematically summarizes the development of GO-based fluorescent biosensors for the detection of pathogenic bacteria. First, we introduce the functionalization and modification of GO. The design and signal amplification strategies for GO-based fluorescent biosensors are also discussed. Finally, we explore the challenges and new perspectives associated with this field, with the aim of facilitating the development of GO-based fluorescent sensing technologies to prevent the spread of multidrug-resistant bacteria.

Significance

This review will aid in the development of high-performance biosensors for pathogenic bacterial assays.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信