{"title":"用于太赫兹计算机断层扫描的自适应加权布雷格曼-胡贝尔总变异法","authors":"Xingzeng Cha, En Li, Dakun Lai","doi":"10.1002/mop.70023","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>To improve the image quality of terahertz (THz) continuous wave (CW) computed tomography (CT) under sparse-view projections, a sparse-view adaptive-weighted Bregman Huber total variation (AW-BHTV) method is proposed and experimentally evaluated at 0.11 THz. The Huber function is served as the fidelity term and TV function is worked for the regularization term, optimized by the adaptive weights, incorporating with iterative algorithms containing the modified simultaneous algebraic reconstruction technique (MSART) and the iterative filtered back-projection (FBP). Sparse-view reconstruction experiments are carefully implemented via polystyrene (PS) foam samples: Sample 1 and Sample 2, respectively. Under 20 projection angles by MSART based AW-BHTV, the values of rooted mean-square-error (RMSE), peak signal-to-noise ratio (PSNR), structure similarity (SSIM) and feature similarity (FSIM) are 0.0061, 22.1427, 0.8738 and 0.9902 for Sample 1 together with 0.0051, 22.9101, 0.8376 and 0.9885 for Sample 2 separately. All of the results above suggest that the proposed AW-BHTV method can effectively protect image details and strengthen image quality in sparse-view THz CW CT.</p>\n </div>","PeriodicalId":18562,"journal":{"name":"Microwave and Optical Technology Letters","volume":"66 11","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Adaptive Weighted Bregman Huber Total Variation Method for Terahertz Computed Tomography\",\"authors\":\"Xingzeng Cha, En Li, Dakun Lai\",\"doi\":\"10.1002/mop.70023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>To improve the image quality of terahertz (THz) continuous wave (CW) computed tomography (CT) under sparse-view projections, a sparse-view adaptive-weighted Bregman Huber total variation (AW-BHTV) method is proposed and experimentally evaluated at 0.11 THz. The Huber function is served as the fidelity term and TV function is worked for the regularization term, optimized by the adaptive weights, incorporating with iterative algorithms containing the modified simultaneous algebraic reconstruction technique (MSART) and the iterative filtered back-projection (FBP). Sparse-view reconstruction experiments are carefully implemented via polystyrene (PS) foam samples: Sample 1 and Sample 2, respectively. Under 20 projection angles by MSART based AW-BHTV, the values of rooted mean-square-error (RMSE), peak signal-to-noise ratio (PSNR), structure similarity (SSIM) and feature similarity (FSIM) are 0.0061, 22.1427, 0.8738 and 0.9902 for Sample 1 together with 0.0051, 22.9101, 0.8376 and 0.9885 for Sample 2 separately. All of the results above suggest that the proposed AW-BHTV method can effectively protect image details and strengthen image quality in sparse-view THz CW CT.</p>\\n </div>\",\"PeriodicalId\":18562,\"journal\":{\"name\":\"Microwave and Optical Technology Letters\",\"volume\":\"66 11\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microwave and Optical Technology Letters\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/mop.70023\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microwave and Optical Technology Letters","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mop.70023","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Adaptive Weighted Bregman Huber Total Variation Method for Terahertz Computed Tomography
To improve the image quality of terahertz (THz) continuous wave (CW) computed tomography (CT) under sparse-view projections, a sparse-view adaptive-weighted Bregman Huber total variation (AW-BHTV) method is proposed and experimentally evaluated at 0.11 THz. The Huber function is served as the fidelity term and TV function is worked for the regularization term, optimized by the adaptive weights, incorporating with iterative algorithms containing the modified simultaneous algebraic reconstruction technique (MSART) and the iterative filtered back-projection (FBP). Sparse-view reconstruction experiments are carefully implemented via polystyrene (PS) foam samples: Sample 1 and Sample 2, respectively. Under 20 projection angles by MSART based AW-BHTV, the values of rooted mean-square-error (RMSE), peak signal-to-noise ratio (PSNR), structure similarity (SSIM) and feature similarity (FSIM) are 0.0061, 22.1427, 0.8738 and 0.9902 for Sample 1 together with 0.0051, 22.9101, 0.8376 and 0.9885 for Sample 2 separately. All of the results above suggest that the proposed AW-BHTV method can effectively protect image details and strengthen image quality in sparse-view THz CW CT.
期刊介绍:
Microwave and Optical Technology Letters provides quick publication (3 to 6 month turnaround) of the most recent findings and achievements in high frequency technology, from RF to optical spectrum. The journal publishes original short papers and letters on theoretical, applied, and system results in the following areas.
- RF, Microwave, and Millimeter Waves
- Antennas and Propagation
- Submillimeter-Wave and Infrared Technology
- Optical Engineering
All papers are subject to peer review before publication