{"title":"研究基于银纳米粒子的凝胶剂量计在同步辐射 X 射线超高剂量率放射治疗中的应用,与 60Co γ 射线进行比较","authors":"Yasser S. Soliman ,&nbsp;Marie Capron ,&nbsp;Diego Pontoni ,&nbsp;Michael Krisch ,&nbsp;Paolo Pellicioli","doi":"10.1016/j.radphyschem.2024.112351","DOIUrl":null,"url":null,"abstract":"<div><div>A silver nitrate (AgNO<sub>3</sub>) gel was developed and evaluated as a dosimeter for synchrotron X-ray-based studies in microbeam radiation therapy (MRT) and FLASH radiation therapy. The gel was irradiated at the European Synchrotron Radiation Facility (ID17 Biomedical beamline) with a continuous X-ray spectrum in the 50–600 keV range and a dose rate of 11.6 kGy/s. The spectrophotometric response after irradiation at this beamline was compared with the response at a conventional <sup>60</sup>Co γ-ray source providing a dose rate of 0.27 Gy/s. Ag <sup>+</sup> ions in the gel dosimeter undergo reduction to Ag<sup>o</sup> nanoparticles, as detected at 450 nm, which is a surface plasmon resonance band. The intensity of this band increased linearly with increasing absorbed dose up to 100 Gy, and improved with the addition of glycerol. The gel dosimeter exhibited the lowest detectable dose (LDD) of 75.9% lower and a dose deposition of 76% higher for ID17 beamline irradiation than for <sup>60</sup>Co irradiation. The theoretical relative response H<sub>Q,Qo</sub> for the gel irradiated at the synchrotron was 1.70, which is in close agreement with the experimental relative response F<sub>Q,Qo</sub> = 1.76. These results confirm the dose enhancement in the gel irradiated with orthovoltage X-rays. The good properties of the silver nitrate gel, together with its increased sensitivity to orthovoltage X-ray irradiation and modest overall uncertainty of 5.8% (2σ), confirm that the gel is a valid dosimeter for measurements at ultrahigh dose rates for synchrotron radiotherapy. The dosimeter is also a promising candidate for dose enhancement factor measurements in nanoparticle-based radiotherapy techniques.</div></div>","PeriodicalId":20861,"journal":{"name":"Radiation Physics and Chemistry","volume":"227 ","pages":"Article 112351"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study of a gel dosimeter based on Ag nanoparticles for applications in radiation therapy with synchrotron X-rays at ultrahigh dose rate compared to 60Co γ-rays\",\"authors\":\"Yasser S. Soliman ,&nbsp;Marie Capron ,&nbsp;Diego Pontoni ,&nbsp;Michael Krisch ,&nbsp;Paolo Pellicioli\",\"doi\":\"10.1016/j.radphyschem.2024.112351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>A silver nitrate (AgNO<sub>3</sub>) gel was developed and evaluated as a dosimeter for synchrotron X-ray-based studies in microbeam radiation therapy (MRT) and FLASH radiation therapy. The gel was irradiated at the European Synchrotron Radiation Facility (ID17 Biomedical beamline) with a continuous X-ray spectrum in the 50–600 keV range and a dose rate of 11.6 kGy/s. The spectrophotometric response after irradiation at this beamline was compared with the response at a conventional <sup>60</sup>Co γ-ray source providing a dose rate of 0.27 Gy/s. Ag <sup>+</sup> ions in the gel dosimeter undergo reduction to Ag<sup>o</sup> nanoparticles, as detected at 450 nm, which is a surface plasmon resonance band. The intensity of this band increased linearly with increasing absorbed dose up to 100 Gy, and improved with the addition of glycerol. The gel dosimeter exhibited the lowest detectable dose (LDD) of 75.9% lower and a dose deposition of 76% higher for ID17 beamline irradiation than for <sup>60</sup>Co irradiation. The theoretical relative response H<sub>Q,Qo</sub> for the gel irradiated at the synchrotron was 1.70, which is in close agreement with the experimental relative response F<sub>Q,Qo</sub> = 1.76. These results confirm the dose enhancement in the gel irradiated with orthovoltage X-rays. The good properties of the silver nitrate gel, together with its increased sensitivity to orthovoltage X-ray irradiation and modest overall uncertainty of 5.8% (2σ), confirm that the gel is a valid dosimeter for measurements at ultrahigh dose rates for synchrotron radiotherapy. The dosimeter is also a promising candidate for dose enhancement factor measurements in nanoparticle-based radiotherapy techniques.</div></div>\",\"PeriodicalId\":20861,\"journal\":{\"name\":\"Radiation Physics and Chemistry\",\"volume\":\"227 \",\"pages\":\"Article 112351\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation Physics and Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0969806X24008430\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Physics and Chemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969806X24008430","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

摘要

研究人员开发了一种硝酸银(AgNO3)凝胶,并将其作为微束放射治疗(MRT)和FLASH放射治疗中基于同步辐射X射线研究的剂量计进行了评估。凝胶在欧洲同步辐射设施(ID17 生物医学光束线)接受 50-600 keV 范围内的连续 X 射线光谱辐照,剂量率为 11.6 kGy/s。在该光束线照射后的分光光度反应与传统 60Co γ 射线源的反应进行了比较,后者的剂量率为 0.27 Gy/s。凝胶剂量计中的 Ag + 离子还原成 Ago 纳米粒子,在 450 纳米波长处检测到这一表面等离子共振波段。该波段的强度随着吸收剂量的增加而线性增加,最高可达 100 Gy,并随着甘油的加入而提高。凝胶剂量计显示,ID17 光束线辐照的最低可检测剂量(LDD)比 60Co 辐照低 75.9%,剂量沉积高 76%。在同步加速器上辐照凝胶的理论相对响应 HQ,Qo 为 1.70,与实验相对响应 FQ,Qo = 1.76 非常接近。这些结果证实了用正电压 X 射线辐照凝胶时的剂量增强。硝酸银凝胶的良好特性,加上其对正电压 X 射线辐照的更高灵敏度和 5.8% (2σ) 的适度总体不确定性,证实了该凝胶是同步加速器放射治疗超高剂量率测量的有效剂量计。该剂量计也有望用于测量基于纳米粒子的放射治疗技术的剂量增强因子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study of a gel dosimeter based on Ag nanoparticles for applications in radiation therapy with synchrotron X-rays at ultrahigh dose rate compared to 60Co γ-rays
A silver nitrate (AgNO3) gel was developed and evaluated as a dosimeter for synchrotron X-ray-based studies in microbeam radiation therapy (MRT) and FLASH radiation therapy. The gel was irradiated at the European Synchrotron Radiation Facility (ID17 Biomedical beamline) with a continuous X-ray spectrum in the 50–600 keV range and a dose rate of 11.6 kGy/s. The spectrophotometric response after irradiation at this beamline was compared with the response at a conventional 60Co γ-ray source providing a dose rate of 0.27 Gy/s. Ag + ions in the gel dosimeter undergo reduction to Ago nanoparticles, as detected at 450 nm, which is a surface plasmon resonance band. The intensity of this band increased linearly with increasing absorbed dose up to 100 Gy, and improved with the addition of glycerol. The gel dosimeter exhibited the lowest detectable dose (LDD) of 75.9% lower and a dose deposition of 76% higher for ID17 beamline irradiation than for 60Co irradiation. The theoretical relative response HQ,Qo for the gel irradiated at the synchrotron was 1.70, which is in close agreement with the experimental relative response FQ,Qo = 1.76. These results confirm the dose enhancement in the gel irradiated with orthovoltage X-rays. The good properties of the silver nitrate gel, together with its increased sensitivity to orthovoltage X-ray irradiation and modest overall uncertainty of 5.8% (2σ), confirm that the gel is a valid dosimeter for measurements at ultrahigh dose rates for synchrotron radiotherapy. The dosimeter is also a promising candidate for dose enhancement factor measurements in nanoparticle-based radiotherapy techniques.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiation Physics and Chemistry
Radiation Physics and Chemistry 化学-核科学技术
CiteScore
5.60
自引率
17.20%
发文量
574
审稿时长
12 weeks
期刊介绍: Radiation Physics and Chemistry is a multidisciplinary journal that provides a medium for publication of substantial and original papers, reviews, and short communications which focus on research and developments involving ionizing radiation in radiation physics, radiation chemistry and radiation processing. The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. This could include papers that are very similar to previous publications, only with changed target substrates, employed materials, analyzed sites and experimental methods, report results without presenting new insights and/or hypothesis testing, or do not focus on the radiation effects.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信