{"title":"钛-6Al-7Nb在减轻髋关节植入物在使用中出现故障方面的潜力和制造设计考虑因素","authors":"Kingsley Posiyano ,&nbsp;R.V.S. Prasad ,&nbsp;Thywill Cephas Dzogbewu ,&nbsp;Eyitayo O. Olakanmi ,&nbsp;Tshenolo P. Leso ,&nbsp;Keagisitswe Setswalo ,&nbsp;Amantle T. Sello","doi":"10.1016/j.bea.2024.100136","DOIUrl":null,"url":null,"abstract":"<div><div>The hip prosthesis, used to repair or recreate the diseased or damaged hip joint's articulation functionality, greatly influences the outcome of total hip arthroplasty (THA). Currently, the limited lifespan (10–15 years) of hip prostheses presents a serious challenge stemming from poor materials selection, design, as well as manufacturing techniques and this has been amplified further by the rising human life expectancy. Today's hip prostheses are predominantly made of Ti-6Al-4V alloy, which frequently fail owing to wear, modulus mismatch, corrosion, and poor osseointegration. To prolong hip implants’ useful life within the body system, it is crucial to comprehend human hip anatomy and biomechanics, investigate the modes and mechanisms of prosthesis failure, and identify mitigation measures pertaining to materials selection, prosthesis design, and production processes. From this point of view, this article firstly explores the intricate hip joint's structural anatomy in the context of biomechanics principles that influence joint movement and weight bearing. Then, hip implant failure modes and mechanisms are discussed and lastly, the failure mitigation measures are proposed. From this review, Ti-6Al-7Nb known for its excellent corrosion resistance and superior biocompatibility is considered a promising substitute for the mostly used cytotoxic Ti-6Al-4V, functionally graded porosity design mimicking the human bone to enhance mechanical and biomedical properties, more precisely osseointegration and stress shielding, and utilization of the selective laser melting technique capable of fabricating Ti-6Al-7Nb components with intricate shapes and high geometrical accuracy can play a significant role in preventing current hip implant failures.</div></div>","PeriodicalId":72384,"journal":{"name":"Biomedical engineering advances","volume":"8 ","pages":"Article 100136"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The potential of Ti-6Al-7Nb, and design for manufacturing considerations in mitigating failure of hip implants in service\",\"authors\":\"Kingsley Posiyano ,&nbsp;R.V.S. Prasad ,&nbsp;Thywill Cephas Dzogbewu ,&nbsp;Eyitayo O. Olakanmi ,&nbsp;Tshenolo P. Leso ,&nbsp;Keagisitswe Setswalo ,&nbsp;Amantle T. Sello\",\"doi\":\"10.1016/j.bea.2024.100136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The hip prosthesis, used to repair or recreate the diseased or damaged hip joint's articulation functionality, greatly influences the outcome of total hip arthroplasty (THA). Currently, the limited lifespan (10–15 years) of hip prostheses presents a serious challenge stemming from poor materials selection, design, as well as manufacturing techniques and this has been amplified further by the rising human life expectancy. Today's hip prostheses are predominantly made of Ti-6Al-4V alloy, which frequently fail owing to wear, modulus mismatch, corrosion, and poor osseointegration. To prolong hip implants’ useful life within the body system, it is crucial to comprehend human hip anatomy and biomechanics, investigate the modes and mechanisms of prosthesis failure, and identify mitigation measures pertaining to materials selection, prosthesis design, and production processes. From this point of view, this article firstly explores the intricate hip joint's structural anatomy in the context of biomechanics principles that influence joint movement and weight bearing. Then, hip implant failure modes and mechanisms are discussed and lastly, the failure mitigation measures are proposed. From this review, Ti-6Al-7Nb known for its excellent corrosion resistance and superior biocompatibility is considered a promising substitute for the mostly used cytotoxic Ti-6Al-4V, functionally graded porosity design mimicking the human bone to enhance mechanical and biomedical properties, more precisely osseointegration and stress shielding, and utilization of the selective laser melting technique capable of fabricating Ti-6Al-7Nb components with intricate shapes and high geometrical accuracy can play a significant role in preventing current hip implant failures.</div></div>\",\"PeriodicalId\":72384,\"journal\":{\"name\":\"Biomedical engineering advances\",\"volume\":\"8 \",\"pages\":\"Article 100136\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical engineering advances\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667099224000252\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical engineering advances","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667099224000252","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

髋关节假体用于修复或重建病变或受损髋关节的关节功能,对全髋关节置换术(THA)的效果有很大影响。目前,由于材料选择、设计和制造技术不佳,髋关节假体的使用寿命有限(10-15 年),这是一个严峻的挑战。如今的髋关节假体主要由 Ti-6Al-4V 合金制成,经常会因磨损、模量不匹配、腐蚀和骨结合不良而失效。为了延长髋关节假体在人体系统中的使用寿命,了解人体髋关节解剖和生物力学、研究假体失效的模式和机制以及确定与材料选择、假体设计和生产工艺有关的缓解措施至关重要。从这个角度出发,本文首先结合影响关节运动和负重的生物力学原理,探讨了复杂的髋关节结构解剖。然后,讨论了髋关节植入物的失效模式和机制,最后提出了失效缓解措施。综上所述,Ti-6Al-7Nb 以其卓越的耐腐蚀性和良好的生物相容性而闻名,被认为是一种很有前途的替代品,可替代目前使用最多的具有细胞毒性的 Ti-6Al-4V;模仿人体骨骼的功能分级孔隙设计可增强机械和生物医学特性,更精确地实现骨结合和应力屏蔽;利用选择性激光熔化技术可制造出具有复杂形状和高几何精度的 Ti-6Al-7Nb 部件,在防止目前的髋关节植入物失效方面可发挥重要作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The potential of Ti-6Al-7Nb, and design for manufacturing considerations in mitigating failure of hip implants in service

The potential of Ti-6Al-7Nb, and design for manufacturing considerations in mitigating failure of hip implants in service
The hip prosthesis, used to repair or recreate the diseased or damaged hip joint's articulation functionality, greatly influences the outcome of total hip arthroplasty (THA). Currently, the limited lifespan (10–15 years) of hip prostheses presents a serious challenge stemming from poor materials selection, design, as well as manufacturing techniques and this has been amplified further by the rising human life expectancy. Today's hip prostheses are predominantly made of Ti-6Al-4V alloy, which frequently fail owing to wear, modulus mismatch, corrosion, and poor osseointegration. To prolong hip implants’ useful life within the body system, it is crucial to comprehend human hip anatomy and biomechanics, investigate the modes and mechanisms of prosthesis failure, and identify mitigation measures pertaining to materials selection, prosthesis design, and production processes. From this point of view, this article firstly explores the intricate hip joint's structural anatomy in the context of biomechanics principles that influence joint movement and weight bearing. Then, hip implant failure modes and mechanisms are discussed and lastly, the failure mitigation measures are proposed. From this review, Ti-6Al-7Nb known for its excellent corrosion resistance and superior biocompatibility is considered a promising substitute for the mostly used cytotoxic Ti-6Al-4V, functionally graded porosity design mimicking the human bone to enhance mechanical and biomedical properties, more precisely osseointegration and stress shielding, and utilization of the selective laser melting technique capable of fabricating Ti-6Al-7Nb components with intricate shapes and high geometrical accuracy can play a significant role in preventing current hip implant failures.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical engineering advances
Biomedical engineering advances Bioengineering, Biomedical Engineering
自引率
0.00%
发文量
0
审稿时长
59 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信