用于激光扫描胶囊内窥镜的磁性致动器驱动系统

IF 3 3区 计算机科学 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Berkay Kebapcıoğlu , Kuter Erdil , Ahmet Can Erten , Onur Ferhanoğlu , Mustafa Berke Yelten
{"title":"用于激光扫描胶囊内窥镜的磁性致动器驱动系统","authors":"Berkay Kebapcıoğlu ,&nbsp;Kuter Erdil ,&nbsp;Ahmet Can Erten ,&nbsp;Onur Ferhanoğlu ,&nbsp;Mustafa Berke Yelten","doi":"10.1016/j.aeue.2024.155571","DOIUrl":null,"url":null,"abstract":"<div><div>This paper focuses on designing and implementing a power and area-efficient magnetic actuator driver interface integrated circuit for laser scanning capsule endoscopy. The proposed system contains a 3D-printed focus-adjusting actuator embarking a lens, multiple magnets, an external coil, battery, laser, and actuator driver integrated circuit with off-chip components. The actuator features multiple pantograph springs connected to the lens, as well as multiple magnets, enabling precise focusing capability through electromagnetic actuation. A magnetic actuator driver integrated circuit implemented in a commercial 180 nm CMOS process drives the coil at 32 Hz, which is the mechanical resonance frequency of the actuator. A novel control methodology for the driver has been devised, aimed at enhancing driving efficiency and mitigating total harmonic distortion. Simulations and measurements substantiate that the actuator can induce a 3.22 mm focal point displacement while the driver circuit delivers 9.62 mA (RMS) current to the 7.7 mH coil. Under these conditions, the system exhibits an aggregate power consumption of 11.48 mW, thereby achieving a power efficiency of 85.5%.</div></div>","PeriodicalId":50844,"journal":{"name":"Aeu-International Journal of Electronics and Communications","volume":"188 ","pages":"Article 155571"},"PeriodicalIF":3.0000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Magnetic actuator driver system for laser scanning capsule endoscopy\",\"authors\":\"Berkay Kebapcıoğlu ,&nbsp;Kuter Erdil ,&nbsp;Ahmet Can Erten ,&nbsp;Onur Ferhanoğlu ,&nbsp;Mustafa Berke Yelten\",\"doi\":\"10.1016/j.aeue.2024.155571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This paper focuses on designing and implementing a power and area-efficient magnetic actuator driver interface integrated circuit for laser scanning capsule endoscopy. The proposed system contains a 3D-printed focus-adjusting actuator embarking a lens, multiple magnets, an external coil, battery, laser, and actuator driver integrated circuit with off-chip components. The actuator features multiple pantograph springs connected to the lens, as well as multiple magnets, enabling precise focusing capability through electromagnetic actuation. A magnetic actuator driver integrated circuit implemented in a commercial 180 nm CMOS process drives the coil at 32 Hz, which is the mechanical resonance frequency of the actuator. A novel control methodology for the driver has been devised, aimed at enhancing driving efficiency and mitigating total harmonic distortion. Simulations and measurements substantiate that the actuator can induce a 3.22 mm focal point displacement while the driver circuit delivers 9.62 mA (RMS) current to the 7.7 mH coil. Under these conditions, the system exhibits an aggregate power consumption of 11.48 mW, thereby achieving a power efficiency of 85.5%.</div></div>\",\"PeriodicalId\":50844,\"journal\":{\"name\":\"Aeu-International Journal of Electronics and Communications\",\"volume\":\"188 \",\"pages\":\"Article 155571\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aeu-International Journal of Electronics and Communications\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1434841124004576\",\"RegionNum\":3,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aeu-International Journal of Electronics and Communications","FirstCategoryId":"94","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1434841124004576","RegionNum":3,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本文的重点是为激光扫描胶囊内窥镜设计和实现一种省电、省面积的磁性致动器驱动器接口集成电路。所提议的系统包含一个三维打印的聚焦调节致动器,其中包含一个透镜、多块磁铁、一个外部线圈、电池、激光器和带有片外元件的致动器驱动集成电路。致动器具有与透镜相连的多个受电弓弹簧和多个磁铁,可通过电磁致动实现精确对焦功能。磁致动器驱动器集成电路采用商用 180 nm CMOS 工艺,以 32 Hz 的频率驱动线圈,这是致动器的机械共振频率。为驱动器设计了一种新的控制方法,旨在提高驱动效率和减少总谐波失真。模拟和测量结果表明,当驱动器电路为 7.7 mH 线圈提供 9.62 mA(有效值)电流时,致动器可产生 3.22 mm 的焦点位移。在这些条件下,系统的总功耗为 11.48 mW,功率效率达到 85.5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Magnetic actuator driver system for laser scanning capsule endoscopy

Magnetic actuator driver system for laser scanning capsule endoscopy
This paper focuses on designing and implementing a power and area-efficient magnetic actuator driver interface integrated circuit for laser scanning capsule endoscopy. The proposed system contains a 3D-printed focus-adjusting actuator embarking a lens, multiple magnets, an external coil, battery, laser, and actuator driver integrated circuit with off-chip components. The actuator features multiple pantograph springs connected to the lens, as well as multiple magnets, enabling precise focusing capability through electromagnetic actuation. A magnetic actuator driver integrated circuit implemented in a commercial 180 nm CMOS process drives the coil at 32 Hz, which is the mechanical resonance frequency of the actuator. A novel control methodology for the driver has been devised, aimed at enhancing driving efficiency and mitigating total harmonic distortion. Simulations and measurements substantiate that the actuator can induce a 3.22 mm focal point displacement while the driver circuit delivers 9.62 mA (RMS) current to the 7.7 mH coil. Under these conditions, the system exhibits an aggregate power consumption of 11.48 mW, thereby achieving a power efficiency of 85.5%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.90
自引率
18.80%
发文量
292
审稿时长
4.9 months
期刊介绍: AEÜ is an international scientific journal which publishes both original works and invited tutorials. The journal''s scope covers all aspects of theory and design of circuits, systems and devices for electronics, signal processing, and communication, including: signal and system theory, digital signal processing network theory and circuit design information theory, communication theory and techniques, modulation, source and channel coding switching theory and techniques, communication protocols optical communications microwave theory and techniques, radar, sonar antennas, wave propagation AEÜ publishes full papers and letters with very short turn around time but a high standard review process. Review cycles are typically finished within twelve weeks by application of modern electronic communication facilities.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信