主动脉瓣置换术后心房颤动的心脏后引流。

IF 2.3 Q2 MEDICINE, GENERAL & INTERNAL
SAGE Open Medicine Pub Date : 2024-11-16 eCollection Date: 2024-01-01 DOI:10.1177/20503121241296566
Yuichi Koga, Manabu Sato, Eiji Sadashima, Jun Ushigusa, Hiromitsu Kawasaki, Keiji Kamohara
{"title":"主动脉瓣置换术后心房颤动的心脏后引流。","authors":"Yuichi Koga, Manabu Sato, Eiji Sadashima, Jun Ushigusa, Hiromitsu Kawasaki, Keiji Kamohara","doi":"10.1177/20503121241296566","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Postoperative atrial fibrillation occurs in 27% to 40% of patients after cardiac surgery. One cause of postoperative atrial fibrillation is pericardial effusion, which can be a significant source of inflammation. In this study, we investigated the effect of a drain placed in a posterior site to the heart to reduce pericardial effusion in the early postoperative period to prevent postoperative atrial fibrillation.</p><p><strong>Methods: </strong>Participants were patients who underwent initial standby aortic valve replacement at Saga-Ken Medical Centre Koseikan from January 2010 to December 2021. Patients with a history of atrial fibrillation, complex surgery, or emergency surgery were excluded. The patients were divided into two groups: those with a posterior cardiac drain in addition to the usual intrapericardial and subpleural drains from September 2017 (group P) and those without posterior cardiac drain from January 2010 to August 2017 (group N). Multiple logistic regression analysis was performed to evaluate the usefulness of posterior cardiac drain.</p><p><strong>Results: </strong>Of the 79 patients included the study, 40 were male and groups P and N comprised 27 and 52 patients, respectively. Of the 79 patients, 32 developed postoperative atrial fibrillation; among whom, 7/27 (25.9%) had posterior cardiac drain and 25/52 (48.1%) had no posterior cardiac drain (<i>p</i> = 0.09). When adjusted for body surface area, left ventricular end-diastolic and left atrial diameter, the incidence of postoperative atrial fibrillation was significantly lower in group P than in group N (adjusted odds ratio 0.270, 95% confidence interval 0.077-0.953, <i>p</i> = 0.042). Furthermore, no patient in the group P underwent postoperative thoracentesis in the subanalysis.</p><p><strong>Conclusions: </strong>The results suggest that early postoperative reduction of pericardial effusion by posterior cardiac drain placement may reduce the incidence of postoperative atrial fibrillation.</p>","PeriodicalId":21398,"journal":{"name":"SAGE Open Medicine","volume":"12 ","pages":"20503121241296566"},"PeriodicalIF":2.3000,"publicationDate":"2024-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569479/pdf/","citationCount":"0","resultStr":"{\"title\":\"Posterior cardiac drain for atrial fibrillation after aortic valve replacement.\",\"authors\":\"Yuichi Koga, Manabu Sato, Eiji Sadashima, Jun Ushigusa, Hiromitsu Kawasaki, Keiji Kamohara\",\"doi\":\"10.1177/20503121241296566\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Postoperative atrial fibrillation occurs in 27% to 40% of patients after cardiac surgery. One cause of postoperative atrial fibrillation is pericardial effusion, which can be a significant source of inflammation. In this study, we investigated the effect of a drain placed in a posterior site to the heart to reduce pericardial effusion in the early postoperative period to prevent postoperative atrial fibrillation.</p><p><strong>Methods: </strong>Participants were patients who underwent initial standby aortic valve replacement at Saga-Ken Medical Centre Koseikan from January 2010 to December 2021. Patients with a history of atrial fibrillation, complex surgery, or emergency surgery were excluded. The patients were divided into two groups: those with a posterior cardiac drain in addition to the usual intrapericardial and subpleural drains from September 2017 (group P) and those without posterior cardiac drain from January 2010 to August 2017 (group N). Multiple logistic regression analysis was performed to evaluate the usefulness of posterior cardiac drain.</p><p><strong>Results: </strong>Of the 79 patients included the study, 40 were male and groups P and N comprised 27 and 52 patients, respectively. Of the 79 patients, 32 developed postoperative atrial fibrillation; among whom, 7/27 (25.9%) had posterior cardiac drain and 25/52 (48.1%) had no posterior cardiac drain (<i>p</i> = 0.09). When adjusted for body surface area, left ventricular end-diastolic and left atrial diameter, the incidence of postoperative atrial fibrillation was significantly lower in group P than in group N (adjusted odds ratio 0.270, 95% confidence interval 0.077-0.953, <i>p</i> = 0.042). Furthermore, no patient in the group P underwent postoperative thoracentesis in the subanalysis.</p><p><strong>Conclusions: </strong>The results suggest that early postoperative reduction of pericardial effusion by posterior cardiac drain placement may reduce the incidence of postoperative atrial fibrillation.</p>\",\"PeriodicalId\":21398,\"journal\":{\"name\":\"SAGE Open Medicine\",\"volume\":\"12 \",\"pages\":\"20503121241296566\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569479/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SAGE Open Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/20503121241296566\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SAGE Open Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20503121241296566","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:27% 至 40% 的心脏手术患者会出现术后心房颤动。心包积液是导致术后心房颤动的原因之一,它可能是炎症的重要来源。在这项研究中,我们探讨了在术后早期将引流管放置在心脏后部以减少心包积液,从而预防术后心房颤动的效果:参与者为2010年1月至2021年12月期间在佐贺县甲生馆医疗中心接受初次备用主动脉瓣置换术的患者。排除有心房颤动病史、复杂手术或急诊手术的患者。患者分为两组:自2017年9月起除了常规的心包内引流管和胸膜下引流管外还使用心脏后引流管的患者(P组)和自2010年1月至2017年8月期间未使用心脏后引流管的患者(N组)。为评估心脏后引流管的作用,进行了多元逻辑回归分析:在纳入研究的79例患者中,40例为男性,P组和N组分别有27例和52例患者。在79名患者中,32名患者术后出现心房颤动,其中7/27(25.9%)患者有心脏后引流管,25/52(48.1%)患者没有心脏后引流管(P = 0.09)。根据体表面积、左室舒张末期和左房直径进行调整后,P 组术后心房颤动的发生率明显低于 N 组(调整后的几率比 0.270,95% 置信区间 0.077-0.953,P = 0.042)。此外,在子分析中,P 组没有患者在术后接受胸腔穿刺术:结果表明,术后早期通过放置心脏后引流管减少心包积液可降低术后心房颤动的发生率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Posterior cardiac drain for atrial fibrillation after aortic valve replacement.

Background: Postoperative atrial fibrillation occurs in 27% to 40% of patients after cardiac surgery. One cause of postoperative atrial fibrillation is pericardial effusion, which can be a significant source of inflammation. In this study, we investigated the effect of a drain placed in a posterior site to the heart to reduce pericardial effusion in the early postoperative period to prevent postoperative atrial fibrillation.

Methods: Participants were patients who underwent initial standby aortic valve replacement at Saga-Ken Medical Centre Koseikan from January 2010 to December 2021. Patients with a history of atrial fibrillation, complex surgery, or emergency surgery were excluded. The patients were divided into two groups: those with a posterior cardiac drain in addition to the usual intrapericardial and subpleural drains from September 2017 (group P) and those without posterior cardiac drain from January 2010 to August 2017 (group N). Multiple logistic regression analysis was performed to evaluate the usefulness of posterior cardiac drain.

Results: Of the 79 patients included the study, 40 were male and groups P and N comprised 27 and 52 patients, respectively. Of the 79 patients, 32 developed postoperative atrial fibrillation; among whom, 7/27 (25.9%) had posterior cardiac drain and 25/52 (48.1%) had no posterior cardiac drain (p = 0.09). When adjusted for body surface area, left ventricular end-diastolic and left atrial diameter, the incidence of postoperative atrial fibrillation was significantly lower in group P than in group N (adjusted odds ratio 0.270, 95% confidence interval 0.077-0.953, p = 0.042). Furthermore, no patient in the group P underwent postoperative thoracentesis in the subanalysis.

Conclusions: The results suggest that early postoperative reduction of pericardial effusion by posterior cardiac drain placement may reduce the incidence of postoperative atrial fibrillation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
SAGE Open Medicine
SAGE Open Medicine MEDICINE, GENERAL & INTERNAL-
CiteScore
3.50
自引率
4.30%
发文量
289
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信