FlowDiff:一种基于流式细胞仪进行白细胞差分计数的简单方法。

IF 1.3 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Konstantinos Dimopoulos, Delphine Bonneau, Jens Hannibal
{"title":"FlowDiff:一种基于流式细胞仪进行白细胞差分计数的简单方法。","authors":"Konstantinos Dimopoulos, Delphine Bonneau, Jens Hannibal","doi":"10.1080/00365513.2024.2426140","DOIUrl":null,"url":null,"abstract":"<p><p>To overcome the challenges of a manual leukocyte differential count, we have developed FlowDiff, an 8-colour, single tube flow cytometry panel, and investigated whether it could potentially replace the manual differential in our laboratory. The instrument was set up in accordance with the EuroFlow settings, and the protocol comprised a stain-lyse no wash process, taking approximately 30 min of working time, without the addition of a toxic lysis reagent. We found a very good correlation for all leukocyte populations between FlowDiff and the Sysmex XN analyzer in 80 normal, non-flagged samples. In addition, FlowDiff showed a very good correlation with manual differential in 168 abnormal samples, as well as a high diagnostic accuracy. FlowDiff correctly identified all samples with acute leukemia (<i>N</i> = 13) and differentiated all B-lymphomas (<i>N</i> = 49) in samples with lymphocytosis. Moreover, FlowDiff detected an additional five samples with B-lymphocytosis without any prior hematological malignancy, which turned out to be a B-lymphoma. Our data suggest that FlowDiff, our 8-colour flow cytometry-based differential, is comparable to, and can successfully substitute the manual differential.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"1-9"},"PeriodicalIF":1.3000,"publicationDate":"2024-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"FlowDiff: a simple, flow cytometry-based approach for performing a leukocyte differential count.\",\"authors\":\"Konstantinos Dimopoulos, Delphine Bonneau, Jens Hannibal\",\"doi\":\"10.1080/00365513.2024.2426140\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>To overcome the challenges of a manual leukocyte differential count, we have developed FlowDiff, an 8-colour, single tube flow cytometry panel, and investigated whether it could potentially replace the manual differential in our laboratory. The instrument was set up in accordance with the EuroFlow settings, and the protocol comprised a stain-lyse no wash process, taking approximately 30 min of working time, without the addition of a toxic lysis reagent. We found a very good correlation for all leukocyte populations between FlowDiff and the Sysmex XN analyzer in 80 normal, non-flagged samples. In addition, FlowDiff showed a very good correlation with manual differential in 168 abnormal samples, as well as a high diagnostic accuracy. FlowDiff correctly identified all samples with acute leukemia (<i>N</i> = 13) and differentiated all B-lymphomas (<i>N</i> = 49) in samples with lymphocytosis. Moreover, FlowDiff detected an additional five samples with B-lymphocytosis without any prior hematological malignancy, which turned out to be a B-lymphoma. Our data suggest that FlowDiff, our 8-colour flow cytometry-based differential, is comparable to, and can successfully substitute the manual differential.</p>\",\"PeriodicalId\":21474,\"journal\":{\"name\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"volume\":\" \",\"pages\":\"1-9\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/00365513.2024.2426140\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2024.2426140","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

为了克服人工白细胞鉴别计数的难题,我们开发了一种 8 色单管流式细胞计数板 FlowDiff,并研究了它是否有可能取代实验室中的人工鉴别计数。该仪器按照 EuroFlow 的设置进行设置,操作规程包括染色-溶解-免清洗过程,工作时间约为 30 分钟,不添加有毒的裂解试剂。我们发现,在 80 份正常的非滞后样本中,FlowDiff 和 Sysmex XN 分析仪对所有白细胞群的检测结果都有很好的相关性。此外,在 168 份异常样本中,FlowDiff 与人工鉴别的相关性非常好,诊断准确率也很高。FlowDiff 能正确识别所有急性白血病样本(13 例),并能区分淋巴细胞增多样本中的所有 B 淋巴瘤(49 例)。此外,FlowDiff 还检测出另外 5 份 B 淋巴细胞增多的样本,这些样本之前未患任何血液恶性肿瘤,但后来发现是 B 淋巴瘤。我们的数据表明,FlowDiff--我们基于 8 色流式细胞仪的鉴别方法--可与人工鉴别方法相媲美,并能成功替代人工鉴别方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
FlowDiff: a simple, flow cytometry-based approach for performing a leukocyte differential count.

To overcome the challenges of a manual leukocyte differential count, we have developed FlowDiff, an 8-colour, single tube flow cytometry panel, and investigated whether it could potentially replace the manual differential in our laboratory. The instrument was set up in accordance with the EuroFlow settings, and the protocol comprised a stain-lyse no wash process, taking approximately 30 min of working time, without the addition of a toxic lysis reagent. We found a very good correlation for all leukocyte populations between FlowDiff and the Sysmex XN analyzer in 80 normal, non-flagged samples. In addition, FlowDiff showed a very good correlation with manual differential in 168 abnormal samples, as well as a high diagnostic accuracy. FlowDiff correctly identified all samples with acute leukemia (N = 13) and differentiated all B-lymphomas (N = 49) in samples with lymphocytosis. Moreover, FlowDiff detected an additional five samples with B-lymphocytosis without any prior hematological malignancy, which turned out to be a B-lymphoma. Our data suggest that FlowDiff, our 8-colour flow cytometry-based differential, is comparable to, and can successfully substitute the manual differential.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
85
审稿时长
4-8 weeks
期刊介绍: The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry. The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信