{"title":"使用多孔三维纤维素/碳纳米管网络的高灵敏度连续葡萄糖传感器。","authors":"Xiaoyan Wang, Zhiyang Dong, Wei Li, DanDan Xiao, Guodong Liu, Zhiqiang Yu, Sijie Yin, Minmin Liang","doi":"10.1016/j.talanta.2024.127201","DOIUrl":null,"url":null,"abstract":"<p><p>While numerous needle-based continuous glucose monitoring (CGM) devices have been available today, the insufficient enzyme immobilization on monitoring sensor severely limited the detection sensitivity of CGM devices. This manuscript describes here a high-sensitivity continuous glucose sensor (CGS) by engineering a porous 3D cellulose/carbon nanotube (CNT) network on the working electrode, which subcutaneously increases the detection enzyme capacity and thus significantly enhances the signal intensity and sensitivity. Furthermore, a tapered needle made of soft resin is engraved into three distinct microgrooves where the glucose oxidase (GOD)-modified working electrode, Pt-modified counter electrode, and Ag/AgCl-modified reference electrode are separately constructed inside the microgrooves. Moreover, a miniature potentiostat tailored for signal acquisition, processing, and transmission is engineered. After incorporated with a wireless circuit, the proposed CGS achieves continuous glucose monitoring in interstitial fluid with a surprising sensitivity of 9.15 μA/mM/cm<sup>2</sup>, as well as maintaining functionality for a period of up to 9 days in live rats. This work provides the public a high-sensitivity continuous glucose monitoring device.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"283 ","pages":"127201"},"PeriodicalIF":5.6000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A high-sensitivity continuous glucose sensor using porous 3D cellulose/ carbon nanotube network.\",\"authors\":\"Xiaoyan Wang, Zhiyang Dong, Wei Li, DanDan Xiao, Guodong Liu, Zhiqiang Yu, Sijie Yin, Minmin Liang\",\"doi\":\"10.1016/j.talanta.2024.127201\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>While numerous needle-based continuous glucose monitoring (CGM) devices have been available today, the insufficient enzyme immobilization on monitoring sensor severely limited the detection sensitivity of CGM devices. This manuscript describes here a high-sensitivity continuous glucose sensor (CGS) by engineering a porous 3D cellulose/carbon nanotube (CNT) network on the working electrode, which subcutaneously increases the detection enzyme capacity and thus significantly enhances the signal intensity and sensitivity. Furthermore, a tapered needle made of soft resin is engraved into three distinct microgrooves where the glucose oxidase (GOD)-modified working electrode, Pt-modified counter electrode, and Ag/AgCl-modified reference electrode are separately constructed inside the microgrooves. Moreover, a miniature potentiostat tailored for signal acquisition, processing, and transmission is engineered. After incorporated with a wireless circuit, the proposed CGS achieves continuous glucose monitoring in interstitial fluid with a surprising sensitivity of 9.15 μA/mM/cm<sup>2</sup>, as well as maintaining functionality for a period of up to 9 days in live rats. This work provides the public a high-sensitivity continuous glucose monitoring device.</p>\",\"PeriodicalId\":435,\"journal\":{\"name\":\"Talanta\",\"volume\":\"283 \",\"pages\":\"127201\"},\"PeriodicalIF\":5.6000,\"publicationDate\":\"2025-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.talanta.2024.127201\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2024.127201","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
A high-sensitivity continuous glucose sensor using porous 3D cellulose/ carbon nanotube network.
While numerous needle-based continuous glucose monitoring (CGM) devices have been available today, the insufficient enzyme immobilization on monitoring sensor severely limited the detection sensitivity of CGM devices. This manuscript describes here a high-sensitivity continuous glucose sensor (CGS) by engineering a porous 3D cellulose/carbon nanotube (CNT) network on the working electrode, which subcutaneously increases the detection enzyme capacity and thus significantly enhances the signal intensity and sensitivity. Furthermore, a tapered needle made of soft resin is engraved into three distinct microgrooves where the glucose oxidase (GOD)-modified working electrode, Pt-modified counter electrode, and Ag/AgCl-modified reference electrode are separately constructed inside the microgrooves. Moreover, a miniature potentiostat tailored for signal acquisition, processing, and transmission is engineered. After incorporated with a wireless circuit, the proposed CGS achieves continuous glucose monitoring in interstitial fluid with a surprising sensitivity of 9.15 μA/mM/cm2, as well as maintaining functionality for a period of up to 9 days in live rats. This work provides the public a high-sensitivity continuous glucose monitoring device.
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.