Sivasankar Kulandaivel, Yung-Kang Lu, Chia-Her Lin and Yi-Chun Yeh
{"title":"用于灵敏细菌内毒素检测的双功能 PCN-242 (Fe2Co) MOF。","authors":"Sivasankar Kulandaivel, Yung-Kang Lu, Chia-Her Lin and Yi-Chun Yeh","doi":"10.1039/D4TB01944J","DOIUrl":null,"url":null,"abstract":"<p >Endotoxin detection is paramount for monitoring bacterial contamination in food, pharmaceuticals, and clinical diagnostics. The limulus amebocyte lysate (LAL) test, which relies on horseshoe crab blood, has long been the gold standard for endotoxin detection. However, the widespread adoption of this method is constrained by ethical concerns and the high costs associated with harvesting endangered species. Although nanozyme-based colorimetric methods present a more cost-effective and straightforward alternative, their application is limited by suboptimal selectivity and sensitivity. In this study, we report the synthesis and rigorous characterization of the bimetallic PCN-242 (Fe<small><sub>2</sub></small>Co) metal–organic framework (MOF), synthesized using 2-amino terephthalic acid and a pre-synthesized [Fe<small><sub>2</sub></small>Co(μ<small><sub>3</sub></small>-O)(CH<small><sub>3</sub></small>COO)<small><sub>6</sub></small>] cluster. Steady-state kinetic analyses revealed that PCN-242 (Fe<small><sub>2</sub></small>Co) MOF exhibits a significantly higher affinity for hydrogen peroxide (H<small><sub>2</sub></small>O<small><sub>2</sub></small>) compared to horseradish peroxidase (HRP) and other iron-based MOFs. The development of a PCN-242 (Fe<small><sub>2</sub></small>Co)-based colorimetric sensor demonstrated a low limit of detection (LOD) of 1.36 μg mL<small><sup>−1</sup></small> for endotoxins, with excellent selectivity and reproducibility, thereby enabling effective detection of bacterial endotoxins. Recognizing the potential of the PCN-242 (Fe<small><sub>2</sub></small>Co) MOF beyond endotoxin detection, we explored its utility in glucose biosensing. Moreover, incorporating glucose oxidase (GOx) into the PCN-242 (Fe<small><sub>2</sub></small>Co) MOF framework further enhanced its peroxidase-like catalytic activity. This integration enabled sensitive glucose detection, achieving LODs of 4.24 μM for glucose and 2.2 μM for H<small><sub>2</sub></small>O<small><sub>2</sub></small> within a linear range of 1 to 150 μM. The dual functionality of PCN-242 (Fe<small><sub>2</sub></small>Co) MOF as a peroxidase mimic and biosensor platform highlights its potential for advanced catalytic and diagnostic applications, offering a versatile and ethical alternative to conventional methods.</p>","PeriodicalId":83,"journal":{"name":"Journal of Materials Chemistry B","volume":" 1","pages":" 151-159"},"PeriodicalIF":6.1000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dual-functional PCN-242 (Fe2Co) MOF for sensitive bacterial endotoxin detection†\",\"authors\":\"Sivasankar Kulandaivel, Yung-Kang Lu, Chia-Her Lin and Yi-Chun Yeh\",\"doi\":\"10.1039/D4TB01944J\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Endotoxin detection is paramount for monitoring bacterial contamination in food, pharmaceuticals, and clinical diagnostics. The limulus amebocyte lysate (LAL) test, which relies on horseshoe crab blood, has long been the gold standard for endotoxin detection. However, the widespread adoption of this method is constrained by ethical concerns and the high costs associated with harvesting endangered species. Although nanozyme-based colorimetric methods present a more cost-effective and straightforward alternative, their application is limited by suboptimal selectivity and sensitivity. In this study, we report the synthesis and rigorous characterization of the bimetallic PCN-242 (Fe<small><sub>2</sub></small>Co) metal–organic framework (MOF), synthesized using 2-amino terephthalic acid and a pre-synthesized [Fe<small><sub>2</sub></small>Co(μ<small><sub>3</sub></small>-O)(CH<small><sub>3</sub></small>COO)<small><sub>6</sub></small>] cluster. Steady-state kinetic analyses revealed that PCN-242 (Fe<small><sub>2</sub></small>Co) MOF exhibits a significantly higher affinity for hydrogen peroxide (H<small><sub>2</sub></small>O<small><sub>2</sub></small>) compared to horseradish peroxidase (HRP) and other iron-based MOFs. The development of a PCN-242 (Fe<small><sub>2</sub></small>Co)-based colorimetric sensor demonstrated a low limit of detection (LOD) of 1.36 μg mL<small><sup>−1</sup></small> for endotoxins, with excellent selectivity and reproducibility, thereby enabling effective detection of bacterial endotoxins. Recognizing the potential of the PCN-242 (Fe<small><sub>2</sub></small>Co) MOF beyond endotoxin detection, we explored its utility in glucose biosensing. Moreover, incorporating glucose oxidase (GOx) into the PCN-242 (Fe<small><sub>2</sub></small>Co) MOF framework further enhanced its peroxidase-like catalytic activity. This integration enabled sensitive glucose detection, achieving LODs of 4.24 μM for glucose and 2.2 μM for H<small><sub>2</sub></small>O<small><sub>2</sub></small> within a linear range of 1 to 150 μM. The dual functionality of PCN-242 (Fe<small><sub>2</sub></small>Co) MOF as a peroxidase mimic and biosensor platform highlights its potential for advanced catalytic and diagnostic applications, offering a versatile and ethical alternative to conventional methods.</p>\",\"PeriodicalId\":83,\"journal\":{\"name\":\"Journal of Materials Chemistry B\",\"volume\":\" 1\",\"pages\":\" 151-159\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2024-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Materials Chemistry B\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2025/tb/d4tb01944j\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Materials Chemistry B","FirstCategoryId":"1","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/tb/d4tb01944j","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Dual-functional PCN-242 (Fe2Co) MOF for sensitive bacterial endotoxin detection†
Endotoxin detection is paramount for monitoring bacterial contamination in food, pharmaceuticals, and clinical diagnostics. The limulus amebocyte lysate (LAL) test, which relies on horseshoe crab blood, has long been the gold standard for endotoxin detection. However, the widespread adoption of this method is constrained by ethical concerns and the high costs associated with harvesting endangered species. Although nanozyme-based colorimetric methods present a more cost-effective and straightforward alternative, their application is limited by suboptimal selectivity and sensitivity. In this study, we report the synthesis and rigorous characterization of the bimetallic PCN-242 (Fe2Co) metal–organic framework (MOF), synthesized using 2-amino terephthalic acid and a pre-synthesized [Fe2Co(μ3-O)(CH3COO)6] cluster. Steady-state kinetic analyses revealed that PCN-242 (Fe2Co) MOF exhibits a significantly higher affinity for hydrogen peroxide (H2O2) compared to horseradish peroxidase (HRP) and other iron-based MOFs. The development of a PCN-242 (Fe2Co)-based colorimetric sensor demonstrated a low limit of detection (LOD) of 1.36 μg mL−1 for endotoxins, with excellent selectivity and reproducibility, thereby enabling effective detection of bacterial endotoxins. Recognizing the potential of the PCN-242 (Fe2Co) MOF beyond endotoxin detection, we explored its utility in glucose biosensing. Moreover, incorporating glucose oxidase (GOx) into the PCN-242 (Fe2Co) MOF framework further enhanced its peroxidase-like catalytic activity. This integration enabled sensitive glucose detection, achieving LODs of 4.24 μM for glucose and 2.2 μM for H2O2 within a linear range of 1 to 150 μM. The dual functionality of PCN-242 (Fe2Co) MOF as a peroxidase mimic and biosensor platform highlights its potential for advanced catalytic and diagnostic applications, offering a versatile and ethical alternative to conventional methods.
期刊介绍:
Journal of Materials Chemistry A, B & C cover high quality studies across all fields of materials chemistry. The journals focus on those theoretical or experimental studies that report new understanding, applications, properties and synthesis of materials. Journal of Materials Chemistry A, B & C are separated by the intended application of the material studied. Broadly, applications in energy and sustainability are of interest to Journal of Materials Chemistry A, applications in biology and medicine are of interest to Journal of Materials Chemistry B, and applications in optical, magnetic and electronic devices are of interest to Journal of Materials Chemistry C.Journal of Materials Chemistry B is a Transformative Journal and Plan S compliant. Example topic areas within the scope of Journal of Materials Chemistry B are listed below. This list is neither exhaustive nor exclusive:
Antifouling coatings
Biocompatible materials
Bioelectronics
Bioimaging
Biomimetics
Biomineralisation
Bionics
Biosensors
Diagnostics
Drug delivery
Gene delivery
Immunobiology
Nanomedicine
Regenerative medicine & Tissue engineering
Scaffolds
Soft robotics
Stem cells
Therapeutic devices