Pelden Wangchuk, Cila Umat, Foong Yen Chong, Faizah Mohd Zaki, Asma Abdullah
{"title":"经验丰富的成年人工耳蜗使用者使用基于解剖学的适配图后的语音感知效果:纵向研究。","authors":"Pelden Wangchuk, Cila Umat, Foong Yen Chong, Faizah Mohd Zaki, Asma Abdullah","doi":"10.1159/000540965","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Anatomy-based fitting (ABF), a relatively new technique for cochlear implant programming, attempts to lessen the impact of the electrode insertion location-related frequency-to-place mismatch (FPM). This study aimed to compare vowels and consonant perception in quiet and in noise among experienced adult cochlear implant (CI) users using the ABF and the regular, conventional-based fitting (CBF) map (pre-ABF) over six months.</p><p><strong>Method: </strong>Nine ears from eight experienced adult CI users were included in the experimental and longitudinal research. Using surgical planning software called Otoplan, post-operative computed CT scans were used to determine the locations of intracochlear electrodes and their angle of insertion. The anatomy-based frequency bands were produced by Maestro 9.0 CI fitting software using the Otoplan data. Nonsense syllables with consonant-vowel-consonant (CVC) recognition scores in quiet and noise (+5dB SNR) were compared at baseline, three, and six months after ABF. The vowels involved were /a, i, u/, while the consonants were voiced /b, d, g/ and voiceless /p, t, k/ plosives. Speech pieces were presented at 30 dB SL in a sound-treated room through a loudspeaker positioned at 0° azimuth.</p><p><strong>Results: </strong>On average, the ABF maps shifted center frequency ranging from 0.46 semitones (0.04 octave) at (E12) to 23.94 semitones (1.99 octave) at (E1) as compared to the CBF maps. The mean vowel and consonant identification scores in quiet and in noise were significantly higher in ABF than in CBF (p<0.05) with a large effect size and the trend of improvement was seen with time. Voiced consonants had better scores than the voiceless consonants.</p><p><strong>Conclusion: </strong>The results demonstrated improved perception of vowels and consonants, particularly for sounds containing voicing cues after using the ABF maps. The results also suggested that ABF could be more effective for voice detection in noise. Overall, the findings indicate that correcting place mismatch with an ABF map may improve speech perception, at least among experienced adult cochlear implant users.</p>","PeriodicalId":55432,"journal":{"name":"Audiology and Neuro-Otology","volume":" ","pages":"1-30"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Speech Perception Outcomes with the Anatomy-Based Fitting Map Among Experienced, Adult Cochlear Implant Users: A Longitudinal Study.\",\"authors\":\"Pelden Wangchuk, Cila Umat, Foong Yen Chong, Faizah Mohd Zaki, Asma Abdullah\",\"doi\":\"10.1159/000540965\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Anatomy-based fitting (ABF), a relatively new technique for cochlear implant programming, attempts to lessen the impact of the electrode insertion location-related frequency-to-place mismatch (FPM). This study aimed to compare vowels and consonant perception in quiet and in noise among experienced adult cochlear implant (CI) users using the ABF and the regular, conventional-based fitting (CBF) map (pre-ABF) over six months.</p><p><strong>Method: </strong>Nine ears from eight experienced adult CI users were included in the experimental and longitudinal research. Using surgical planning software called Otoplan, post-operative computed CT scans were used to determine the locations of intracochlear electrodes and their angle of insertion. The anatomy-based frequency bands were produced by Maestro 9.0 CI fitting software using the Otoplan data. Nonsense syllables with consonant-vowel-consonant (CVC) recognition scores in quiet and noise (+5dB SNR) were compared at baseline, three, and six months after ABF. The vowels involved were /a, i, u/, while the consonants were voiced /b, d, g/ and voiceless /p, t, k/ plosives. Speech pieces were presented at 30 dB SL in a sound-treated room through a loudspeaker positioned at 0° azimuth.</p><p><strong>Results: </strong>On average, the ABF maps shifted center frequency ranging from 0.46 semitones (0.04 octave) at (E12) to 23.94 semitones (1.99 octave) at (E1) as compared to the CBF maps. The mean vowel and consonant identification scores in quiet and in noise were significantly higher in ABF than in CBF (p<0.05) with a large effect size and the trend of improvement was seen with time. Voiced consonants had better scores than the voiceless consonants.</p><p><strong>Conclusion: </strong>The results demonstrated improved perception of vowels and consonants, particularly for sounds containing voicing cues after using the ABF maps. The results also suggested that ABF could be more effective for voice detection in noise. Overall, the findings indicate that correcting place mismatch with an ABF map may improve speech perception, at least among experienced adult cochlear implant users.</p>\",\"PeriodicalId\":55432,\"journal\":{\"name\":\"Audiology and Neuro-Otology\",\"volume\":\" \",\"pages\":\"1-30\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Audiology and Neuro-Otology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000540965\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology and Neuro-Otology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000540965","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
Speech Perception Outcomes with the Anatomy-Based Fitting Map Among Experienced, Adult Cochlear Implant Users: A Longitudinal Study.
Introduction: Anatomy-based fitting (ABF), a relatively new technique for cochlear implant programming, attempts to lessen the impact of the electrode insertion location-related frequency-to-place mismatch (FPM). This study aimed to compare vowels and consonant perception in quiet and in noise among experienced adult cochlear implant (CI) users using the ABF and the regular, conventional-based fitting (CBF) map (pre-ABF) over six months.
Method: Nine ears from eight experienced adult CI users were included in the experimental and longitudinal research. Using surgical planning software called Otoplan, post-operative computed CT scans were used to determine the locations of intracochlear electrodes and their angle of insertion. The anatomy-based frequency bands were produced by Maestro 9.0 CI fitting software using the Otoplan data. Nonsense syllables with consonant-vowel-consonant (CVC) recognition scores in quiet and noise (+5dB SNR) were compared at baseline, three, and six months after ABF. The vowels involved were /a, i, u/, while the consonants were voiced /b, d, g/ and voiceless /p, t, k/ plosives. Speech pieces were presented at 30 dB SL in a sound-treated room through a loudspeaker positioned at 0° azimuth.
Results: On average, the ABF maps shifted center frequency ranging from 0.46 semitones (0.04 octave) at (E12) to 23.94 semitones (1.99 octave) at (E1) as compared to the CBF maps. The mean vowel and consonant identification scores in quiet and in noise were significantly higher in ABF than in CBF (p<0.05) with a large effect size and the trend of improvement was seen with time. Voiced consonants had better scores than the voiceless consonants.
Conclusion: The results demonstrated improved perception of vowels and consonants, particularly for sounds containing voicing cues after using the ABF maps. The results also suggested that ABF could be more effective for voice detection in noise. Overall, the findings indicate that correcting place mismatch with an ABF map may improve speech perception, at least among experienced adult cochlear implant users.
期刊介绍:
''Audiology and Neurotology'' provides a forum for the publication of the most-advanced and rigorous scientific research related to the basic science and clinical aspects of the auditory and vestibular system and diseases of the ear. This journal seeks submission of cutting edge research opening up new and innovative fields of study that may improve our understanding and treatment of patients with disorders of the auditory and vestibular systems, their central connections and their perception in the central nervous system. In addition to original papers the journal also offers invited review articles on current topics written by leading experts in the field. The journal is of primary importance for all scientists and practitioners interested in audiology, otology and neurotology, auditory neurosciences and related disciplines.