在没有乳化的情况下,早期硅油不透明是由于二氧化硅含量增加造成的。

IF 2.3 2区 医学 Q2 OPHTHALMOLOGY
Maximilian Hammer, Leoni Britz, Manuel Ben Böhmann, Lorenz Herbster, Marcel Muuss, Jonathan Herth, Sebastian Cionoiu, Holger Krisp, Martin Stephan Spitzer, Sabrina Wohlfart, Philipp Uhl, Gerd Uwe Auffarth
{"title":"在没有乳化的情况下,早期硅油不透明是由于二氧化硅含量增加造成的。","authors":"Maximilian Hammer, Leoni Britz, Manuel Ben Böhmann, Lorenz Herbster, Marcel Muuss, Jonathan Herth, Sebastian Cionoiu, Holger Krisp, Martin Stephan Spitzer, Sabrina Wohlfart, Philipp Uhl, Gerd Uwe Auffarth","doi":"10.1097/IAE.0000000000004324","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In October 2023, other cases with early silicone oil opacification within hours after intraocular implantation in the absence of emulsification occurred. While multiple, small series of this phenomenon are now documented during the last decade, the cause was never unmasked. In this study, we analyzed explanted patient samples, unused samples of the affected, and a control batch of the same silicone oil.</p><p><strong>Methods: </strong>The oils were examined on their optical and viscosimetric properties, interfacial tension and for presence of particles. Contamination was investigated using Inductively Coupled Plasma - Mass Spectrometry, thermogravimetric analyses, and Raman-spectroscopy. Cytotoxicity examination in ARPE-19 cells was performed. The oil's effect on pH-changes of aqueous solutions and the oil's defoaming ability were analyzed.</p><p><strong>Results: </strong>The affected batch passed all regulatory limits. However, the affected batch showed an elevated turbidity already before implantation. 3000-fold magnification revealed dispersed particles only in the affected batch. Contamination analyses revealed the absence of other elements indicating a silicon-containing contamination. The affected batch showed no in-vitro cytotoxicity but altered viscosimetric properties and a lower pH of the hydrophilic phase after inducing emulsification. Both batches did not show relevant defoaming properties.</p><p><strong>Conclusion: </strong>The results obtained combined with information from suppliers and the manufacturer suggest an elevated level of silica particles as the cause of the opacification. Based on these results, the manufacturer and suppliers of the latest affected batch adjusted cut-off values for turbidity measurements and introduced turbidity measurements of the raw material prior to distillation. Other manufacturers should follow these preventive measures.</p>","PeriodicalId":54486,"journal":{"name":"Retina-The Journal of Retinal and Vitreous Diseases","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Early silicone oil opacification in the absence of emulsification is caused by an increased level of silicone dioxide.\",\"authors\":\"Maximilian Hammer, Leoni Britz, Manuel Ben Böhmann, Lorenz Herbster, Marcel Muuss, Jonathan Herth, Sebastian Cionoiu, Holger Krisp, Martin Stephan Spitzer, Sabrina Wohlfart, Philipp Uhl, Gerd Uwe Auffarth\",\"doi\":\"10.1097/IAE.0000000000004324\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>In October 2023, other cases with early silicone oil opacification within hours after intraocular implantation in the absence of emulsification occurred. While multiple, small series of this phenomenon are now documented during the last decade, the cause was never unmasked. In this study, we analyzed explanted patient samples, unused samples of the affected, and a control batch of the same silicone oil.</p><p><strong>Methods: </strong>The oils were examined on their optical and viscosimetric properties, interfacial tension and for presence of particles. Contamination was investigated using Inductively Coupled Plasma - Mass Spectrometry, thermogravimetric analyses, and Raman-spectroscopy. Cytotoxicity examination in ARPE-19 cells was performed. The oil's effect on pH-changes of aqueous solutions and the oil's defoaming ability were analyzed.</p><p><strong>Results: </strong>The affected batch passed all regulatory limits. However, the affected batch showed an elevated turbidity already before implantation. 3000-fold magnification revealed dispersed particles only in the affected batch. Contamination analyses revealed the absence of other elements indicating a silicon-containing contamination. The affected batch showed no in-vitro cytotoxicity but altered viscosimetric properties and a lower pH of the hydrophilic phase after inducing emulsification. Both batches did not show relevant defoaming properties.</p><p><strong>Conclusion: </strong>The results obtained combined with information from suppliers and the manufacturer suggest an elevated level of silica particles as the cause of the opacification. Based on these results, the manufacturer and suppliers of the latest affected batch adjusted cut-off values for turbidity measurements and introduced turbidity measurements of the raw material prior to distillation. Other manufacturers should follow these preventive measures.</p>\",\"PeriodicalId\":54486,\"journal\":{\"name\":\"Retina-The Journal of Retinal and Vitreous Diseases\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Retina-The Journal of Retinal and Vitreous Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/IAE.0000000000004324\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Retina-The Journal of Retinal and Vitreous Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IAE.0000000000004324","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:2023 年 10 月,又出现了眼内植入硅油后数小时内出现早期硅油混浊且无乳化现象的病例。虽然在过去十年中,已有多例小规模的此类现象记录在案,但其原因却从未被揭开。在这项研究中,我们分析了患者取出的样本、未使用过的受影响样本以及同一批次硅油的对照样本:方法:对硅油的光学和粘度特性、界面张力以及是否存在颗粒进行了检测。使用电感耦合等离子体质谱法、热重分析法和拉曼光谱法对污染情况进行了调查。在 ARPE-19 细胞中进行了细胞毒性检测。分析了油对水溶液 pH 值变化的影响以及油的消泡能力:结果:受影响的批次通过了所有法规限制。然而,受影响的批次在植入前就已显示出浑浊度升高。放大 3000 倍后发现,只有受影响批次中存在分散颗粒。污染分析表明不含其他元素,这表明污染中含有硅。受影响的批次未显示体外细胞毒性,但在诱导乳化后,粘度特性发生变化,亲水相的 pH 值降低。两个批次都没有显示出相关的消泡特性:结论:结合供应商和制造商提供的信息得出的结果表明,二氧化硅颗粒含量升高是造成不透明的原因。根据这些结果,最近一批受影响产品的制造商和供应商调整了浊度测量的临界值,并在蒸馏前对原材料进行浊度测量。其他制造商应遵循这些预防措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Early silicone oil opacification in the absence of emulsification is caused by an increased level of silicone dioxide.

Purpose: In October 2023, other cases with early silicone oil opacification within hours after intraocular implantation in the absence of emulsification occurred. While multiple, small series of this phenomenon are now documented during the last decade, the cause was never unmasked. In this study, we analyzed explanted patient samples, unused samples of the affected, and a control batch of the same silicone oil.

Methods: The oils were examined on their optical and viscosimetric properties, interfacial tension and for presence of particles. Contamination was investigated using Inductively Coupled Plasma - Mass Spectrometry, thermogravimetric analyses, and Raman-spectroscopy. Cytotoxicity examination in ARPE-19 cells was performed. The oil's effect on pH-changes of aqueous solutions and the oil's defoaming ability were analyzed.

Results: The affected batch passed all regulatory limits. However, the affected batch showed an elevated turbidity already before implantation. 3000-fold magnification revealed dispersed particles only in the affected batch. Contamination analyses revealed the absence of other elements indicating a silicon-containing contamination. The affected batch showed no in-vitro cytotoxicity but altered viscosimetric properties and a lower pH of the hydrophilic phase after inducing emulsification. Both batches did not show relevant defoaming properties.

Conclusion: The results obtained combined with information from suppliers and the manufacturer suggest an elevated level of silica particles as the cause of the opacification. Based on these results, the manufacturer and suppliers of the latest affected batch adjusted cut-off values for turbidity measurements and introduced turbidity measurements of the raw material prior to distillation. Other manufacturers should follow these preventive measures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.70
自引率
9.10%
发文量
554
审稿时长
3-6 weeks
期刊介绍: ​RETINA® focuses exclusively on the growing specialty of vitreoretinal disorders. The Journal provides current information on diagnostic and therapeutic techniques. Its highly specialized and informative, peer-reviewed articles are easily applicable to clinical practice. In addition to regular reports from clinical and basic science investigators, RETINA® publishes special features including periodic review articles on pertinent topics, special articles dealing with surgical and other therapeutic techniques, and abstract cards. Issues are abundantly illustrated in vivid full color. Published 12 times per year, RETINA® is truly a “must have” publication for anyone connected to this field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信