{"title":"利用磁场测量分析 MAET 中不同激励的脉冲压缩性能和图像质量指标。","authors":"Mehmet Soner Gözü, Nevzat Güneri Gençer","doi":"10.1002/cnm.3890","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigates the pulse compression technique to improve the performance of magneto-acousto-electrical tomography (MAET) with magnetic field measurements through numerical studies. Emphasizing the effects of specific coil configuration on MAET measurements, the study conducts evaluations using a linear phased array (LPA) transducer and numerical breast models with tumor inclusion. It provides feasibility and a detailed comparative analysis of various excitations, including linear frequency modulated (LFM), Barker code, and Golay code excitations in MAET. To simulate experimental conditions, additive White Gaussian noise is added to the MAET signal detected by the receiver coils. The results obtained from the LPA steering angle at 0° and the reconstructed B-mode MAET images using the pulse compression technique lead to improvements compared with conventional single-cycle excitation. The computed mean signal-to-noise ratio (SNR) improvements for LFM, Barker code, and Golay code excitations in B-mode MAET images for 10,000 iterations are 7.42, 8.36, and 8.44 dB, respectively, compared with single-cycle excitation. Similarly, the mean contrast-to-noise ratio (CNR) improvements for these excitations in B-mode MAET images are 1.43, 1.63, and 1.9 dB, respectively. The results demonstrate that Golay code is superior in CNR and image quality metrics, while Golay and Barker codes have comparable SNR and outperform LFM. The research shows that the coil configuration significantly impacts tumor detection. With Golay code excitation, detecting a tumor as small as 5 mm × 2 mm at a depth of 33 mm with an SNR of 6.38 dB is possible, achieving an axial resolution of 2 mm.</p>","PeriodicalId":50349,"journal":{"name":"International Journal for Numerical Methods in Biomedical Engineering","volume":" ","pages":"e3890"},"PeriodicalIF":2.2000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analyzing Pulse Compression Performance and Image Quality Metrics of Different Excitations in MAET With Magnetic Field Measurements.\",\"authors\":\"Mehmet Soner Gözü, Nevzat Güneri Gençer\",\"doi\":\"10.1002/cnm.3890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study investigates the pulse compression technique to improve the performance of magneto-acousto-electrical tomography (MAET) with magnetic field measurements through numerical studies. Emphasizing the effects of specific coil configuration on MAET measurements, the study conducts evaluations using a linear phased array (LPA) transducer and numerical breast models with tumor inclusion. It provides feasibility and a detailed comparative analysis of various excitations, including linear frequency modulated (LFM), Barker code, and Golay code excitations in MAET. To simulate experimental conditions, additive White Gaussian noise is added to the MAET signal detected by the receiver coils. The results obtained from the LPA steering angle at 0° and the reconstructed B-mode MAET images using the pulse compression technique lead to improvements compared with conventional single-cycle excitation. The computed mean signal-to-noise ratio (SNR) improvements for LFM, Barker code, and Golay code excitations in B-mode MAET images for 10,000 iterations are 7.42, 8.36, and 8.44 dB, respectively, compared with single-cycle excitation. Similarly, the mean contrast-to-noise ratio (CNR) improvements for these excitations in B-mode MAET images are 1.43, 1.63, and 1.9 dB, respectively. The results demonstrate that Golay code is superior in CNR and image quality metrics, while Golay and Barker codes have comparable SNR and outperform LFM. The research shows that the coil configuration significantly impacts tumor detection. With Golay code excitation, detecting a tumor as small as 5 mm × 2 mm at a depth of 33 mm with an SNR of 6.38 dB is possible, achieving an axial resolution of 2 mm.</p>\",\"PeriodicalId\":50349,\"journal\":{\"name\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"volume\":\" \",\"pages\":\"e3890\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal for Numerical Methods in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/cnm.3890\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal for Numerical Methods in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/cnm.3890","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究通过数值研究探讨了脉冲压缩技术,以提高磁场测量的磁声电断层成像(MAET)性能。研究强调了特定线圈配置对 MAET 测量的影响,使用线性相控阵(LPA)传感器和包含肿瘤的乳腺数值模型进行了评估。它提供了各种激励的可行性和详细的比较分析,包括 MAET 中的线性频率调制 (LFM)、巴克编码和戈莱编码激励。为了模拟实验条件,在接收线圈检测到的 MAET 信号中加入了加性白高斯噪声。LPA 转向角为 0°,使用脉冲压缩技术重建的 B 模式 MAET 图像与传统的单周期激励相比,结果有所改进。与单周期激励相比,计算得出的 10,000 次迭代的 B 模式 MAET 图像中 LFM、Barker 码和 Golay 码激励的平均信噪比(SNR)分别提高了 7.42、8.36 和 8.44 dB。同样,这些激励在 B 模式 MAET 图像中的平均对比度-噪声比 (CNR) 分别提高了 1.43、1.63 和 1.9 dB。结果表明,Golay 码在 CNR 和图像质量指标方面更胜一筹,而 Golay 码和 Barker 码的信噪比不相上下,并优于 LFM。研究表明,线圈配置对肿瘤检测有重大影响。在戈莱码激励下,可以在 33 毫米深度检测到小至 5 毫米 × 2 毫米的肿瘤,信噪比为 6.38 dB,轴向分辨率达到 2 毫米。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analyzing Pulse Compression Performance and Image Quality Metrics of Different Excitations in MAET With Magnetic Field Measurements.

This study investigates the pulse compression technique to improve the performance of magneto-acousto-electrical tomography (MAET) with magnetic field measurements through numerical studies. Emphasizing the effects of specific coil configuration on MAET measurements, the study conducts evaluations using a linear phased array (LPA) transducer and numerical breast models with tumor inclusion. It provides feasibility and a detailed comparative analysis of various excitations, including linear frequency modulated (LFM), Barker code, and Golay code excitations in MAET. To simulate experimental conditions, additive White Gaussian noise is added to the MAET signal detected by the receiver coils. The results obtained from the LPA steering angle at 0° and the reconstructed B-mode MAET images using the pulse compression technique lead to improvements compared with conventional single-cycle excitation. The computed mean signal-to-noise ratio (SNR) improvements for LFM, Barker code, and Golay code excitations in B-mode MAET images for 10,000 iterations are 7.42, 8.36, and 8.44 dB, respectively, compared with single-cycle excitation. Similarly, the mean contrast-to-noise ratio (CNR) improvements for these excitations in B-mode MAET images are 1.43, 1.63, and 1.9 dB, respectively. The results demonstrate that Golay code is superior in CNR and image quality metrics, while Golay and Barker codes have comparable SNR and outperform LFM. The research shows that the coil configuration significantly impacts tumor detection. With Golay code excitation, detecting a tumor as small as 5 mm × 2 mm at a depth of 33 mm with an SNR of 6.38 dB is possible, achieving an axial resolution of 2 mm.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal for Numerical Methods in Biomedical Engineering
International Journal for Numerical Methods in Biomedical Engineering ENGINEERING, BIOMEDICAL-MATHEMATICAL & COMPUTATIONAL BIOLOGY
CiteScore
4.50
自引率
9.50%
发文量
103
审稿时长
3 months
期刊介绍: All differential equation based models for biomedical applications and their novel solutions (using either established numerical methods such as finite difference, finite element and finite volume methods or new numerical methods) are within the scope of this journal. Manuscripts with experimental and analytical themes are also welcome if a component of the paper deals with numerical methods. Special cases that may not involve differential equations such as image processing, meshing and artificial intelligence are within the scope. Any research that is broadly linked to the wellbeing of the human body, either directly or indirectly, is also within the scope of this journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信