{"title":"开发高伽马和中子背景环境下的α射线可视化测量仪。","authors":"Youichi Tsubota, Kenji Kobayashi, Tatsuya Ishii, Misaki Hirato, Satoshi Shioya, Takahiro Nakagawa","doi":"10.1093/rpd/ncae169","DOIUrl":null,"url":null,"abstract":"<p><p>A survey meter was developed to reliably detect and visualize surface contamination of suits and objects by α-nuclides in high γ/n-rays background radiation environment. The survey meter features a semi-opaque ZnS:Ag scintillator mounted directly onto a multi-anode photomultiplier tube (MA-PMT) and amplification circuits, ensuring output gain equalization for all channels. α-ray events induce localized light emission in thin-film scintillators. By directly mounting the scintillator, diffusion of light before reaching the MA-PMT is suppressed, concentrating it in just a few channels, thereby facilitating discrimination from background radiation. This design also enables clear visualization of the shape of surface contamination. The prototyped survey meter is capable of responding up to 2.1 × 107 cpm, with no γ-ray response even in high-radiation environments exceeding 1 Sv/h. In actual environments with high background radiation, contamination of ~1/100th of the surface contamination density limit of 4 Bq/cm2 could be reliably detected.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of α-ray visualization survey meter in high gamma and neutron background environment.\",\"authors\":\"Youichi Tsubota, Kenji Kobayashi, Tatsuya Ishii, Misaki Hirato, Satoshi Shioya, Takahiro Nakagawa\",\"doi\":\"10.1093/rpd/ncae169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A survey meter was developed to reliably detect and visualize surface contamination of suits and objects by α-nuclides in high γ/n-rays background radiation environment. The survey meter features a semi-opaque ZnS:Ag scintillator mounted directly onto a multi-anode photomultiplier tube (MA-PMT) and amplification circuits, ensuring output gain equalization for all channels. α-ray events induce localized light emission in thin-film scintillators. By directly mounting the scintillator, diffusion of light before reaching the MA-PMT is suppressed, concentrating it in just a few channels, thereby facilitating discrimination from background radiation. This design also enables clear visualization of the shape of surface contamination. The prototyped survey meter is capable of responding up to 2.1 × 107 cpm, with no γ-ray response even in high-radiation environments exceeding 1 Sv/h. In actual environments with high background radiation, contamination of ~1/100th of the surface contamination density limit of 4 Bq/cm2 could be reliably detected.</p>\",\"PeriodicalId\":20795,\"journal\":{\"name\":\"Radiation protection dosimetry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation protection dosimetry\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1093/rpd/ncae169\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae169","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Development of α-ray visualization survey meter in high gamma and neutron background environment.
A survey meter was developed to reliably detect and visualize surface contamination of suits and objects by α-nuclides in high γ/n-rays background radiation environment. The survey meter features a semi-opaque ZnS:Ag scintillator mounted directly onto a multi-anode photomultiplier tube (MA-PMT) and amplification circuits, ensuring output gain equalization for all channels. α-ray events induce localized light emission in thin-film scintillators. By directly mounting the scintillator, diffusion of light before reaching the MA-PMT is suppressed, concentrating it in just a few channels, thereby facilitating discrimination from background radiation. This design also enables clear visualization of the shape of surface contamination. The prototyped survey meter is capable of responding up to 2.1 × 107 cpm, with no γ-ray response even in high-radiation environments exceeding 1 Sv/h. In actual environments with high background radiation, contamination of ~1/100th of the surface contamination density limit of 4 Bq/cm2 could be reliably detected.
期刊介绍:
Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.