衍射型眼内透镜及其新型进化材料版的视觉质量、患者满意度和光现象。

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY
Laureano A Rementería-Capelo, Inés Contreras, Juan Gros-Otero, Laura Mariñas, Javier Ruiz-Alcocer
{"title":"衍射型眼内透镜及其新型进化材料版的视觉质量、患者满意度和光现象。","authors":"Laureano A Rementería-Capelo, Inés Contreras, Juan Gros-Otero, Laura Mariñas, Javier Ruiz-Alcocer","doi":"10.3928/1081597X-20240923-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the visual quality, patient satisfaction, and photic phenomena 3 and 12 months after the implantation of two similar diffractive intraocular lenses (IOLs) manufactured with different materials.</p><p><strong>Methods: </strong>This retrospective observational study included patients with the AcrySof PanOptix IOL or the Clareon Pan-Optix IOL (both Alcon Laboratories, Inc). Three and 12 months after the surgery, binocular contrast sensitivity under photopic conditions was measured. The presence of dysphotopsias and difficulties when driving in dim light conditions was also reported. Patient satisfaction was assessed through the Catquest 9-SF questionnaire and patients also reported the need for additional spectacles at different distances. Twelve months after the surgery, the presence of posterior capsule opacification and glistening was reported.</p><p><strong>Results: </strong>The study included 59 patients. Contrast sensitivity was stable in both groups 12 months after the surgery, the proportion of patients that always perceived halos decreased approximately 15%, and difficulties when driving at night were minimized. Both groups showed high and similar rates of satisfaction with their vision and achieved spectacle independence rates greater than 85% at the two visits. The presence of posterior capsule opacification was similar for both groups, whereas 64% and 90% of the eyes were free of glistening in the AcrySof and Clareon groups, respectively.</p><p><strong>Conclusions: </strong>Both diffractive IOLs offer consistent visual outcomes and high rates of patient satisfaction during the initial 12 months after surgery. The results also suggest that the novel material may better preserve the transparency of the IOL in the long term. <b>[<i>J Refract Surg</i>. 2024;40(11):e877-e883.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 11","pages":"e877-e883"},"PeriodicalIF":2.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual Quality, Patient Satisfaction, and Photic Phenomena With a Diffractive Intraocular Lens and Its New Evolved Materials Version.\",\"authors\":\"Laureano A Rementería-Capelo, Inés Contreras, Juan Gros-Otero, Laura Mariñas, Javier Ruiz-Alcocer\",\"doi\":\"10.3928/1081597X-20240923-02\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the visual quality, patient satisfaction, and photic phenomena 3 and 12 months after the implantation of two similar diffractive intraocular lenses (IOLs) manufactured with different materials.</p><p><strong>Methods: </strong>This retrospective observational study included patients with the AcrySof PanOptix IOL or the Clareon Pan-Optix IOL (both Alcon Laboratories, Inc). Three and 12 months after the surgery, binocular contrast sensitivity under photopic conditions was measured. The presence of dysphotopsias and difficulties when driving in dim light conditions was also reported. Patient satisfaction was assessed through the Catquest 9-SF questionnaire and patients also reported the need for additional spectacles at different distances. Twelve months after the surgery, the presence of posterior capsule opacification and glistening was reported.</p><p><strong>Results: </strong>The study included 59 patients. Contrast sensitivity was stable in both groups 12 months after the surgery, the proportion of patients that always perceived halos decreased approximately 15%, and difficulties when driving at night were minimized. Both groups showed high and similar rates of satisfaction with their vision and achieved spectacle independence rates greater than 85% at the two visits. The presence of posterior capsule opacification was similar for both groups, whereas 64% and 90% of the eyes were free of glistening in the AcrySof and Clareon groups, respectively.</p><p><strong>Conclusions: </strong>Both diffractive IOLs offer consistent visual outcomes and high rates of patient satisfaction during the initial 12 months after surgery. The results also suggest that the novel material may better preserve the transparency of the IOL in the long term. <b>[<i>J Refract Surg</i>. 2024;40(11):e877-e883.]</b>.</p>\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"40 11\",\"pages\":\"e877-e883\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597X-20240923-02\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240923-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估两种使用不同材料制造的类似衍射性眼球内人工晶体(IOL)植入 3 个月和 12 个月后的视觉质量、患者满意度和光现象:这项回顾性观察研究包括使用 AcrySof PanOptix IOL 或 Clareon Pan-Optix IOL(两家公司均为 Alcon Laboratories, Inc)的患者。术后 3 个月和 12 个月,测量了光照条件下的双眼对比敏感度。此外,还报告了患者在昏暗光线条件下开车时是否出现视力障碍和困难。患者的满意度通过 Catquest 9-SF 问卷进行评估,患者还报告了在不同距离下是否需要额外的眼镜。手术 12 个月后,报告了后囊不透明和闪烁的情况:研究包括 59 名患者。手术 12 个月后,两组患者的对比敏感度均保持稳定,总是感觉到光晕的患者比例下降了约 15%,夜间驾驶时的困难也降至最低。两组患者对视力的满意度都很高,而且相差无几,在两次就诊时,眼镜独立率都超过了 85%。两组患者的后囊不透明情况相似,而 AcrySof 组和 Clareon 组分别有 64% 和 90% 的眼睛没有晶状体:结论:两种衍射型人工晶体在术后最初的 12 个月内都能提供一致的视觉效果和较高的患者满意度。结果还表明,新型材料可以更好地长期保持人工晶体的透明度。[J Refract Surg. 2024;40(11):e877-e883]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Visual Quality, Patient Satisfaction, and Photic Phenomena With a Diffractive Intraocular Lens and Its New Evolved Materials Version.

Purpose: To assess the visual quality, patient satisfaction, and photic phenomena 3 and 12 months after the implantation of two similar diffractive intraocular lenses (IOLs) manufactured with different materials.

Methods: This retrospective observational study included patients with the AcrySof PanOptix IOL or the Clareon Pan-Optix IOL (both Alcon Laboratories, Inc). Three and 12 months after the surgery, binocular contrast sensitivity under photopic conditions was measured. The presence of dysphotopsias and difficulties when driving in dim light conditions was also reported. Patient satisfaction was assessed through the Catquest 9-SF questionnaire and patients also reported the need for additional spectacles at different distances. Twelve months after the surgery, the presence of posterior capsule opacification and glistening was reported.

Results: The study included 59 patients. Contrast sensitivity was stable in both groups 12 months after the surgery, the proportion of patients that always perceived halos decreased approximately 15%, and difficulties when driving at night were minimized. Both groups showed high and similar rates of satisfaction with their vision and achieved spectacle independence rates greater than 85% at the two visits. The presence of posterior capsule opacification was similar for both groups, whereas 64% and 90% of the eyes were free of glistening in the AcrySof and Clareon groups, respectively.

Conclusions: Both diffractive IOLs offer consistent visual outcomes and high rates of patient satisfaction during the initial 12 months after surgery. The results also suggest that the novel material may better preserve the transparency of the IOL in the long term. [J Refract Surg. 2024;40(11):e877-e883.].

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信