{"title":"使用 LC-II 螺钉和钢板内固定骨盆后环 C1.1 骨折的实验研究。","authors":"Yu Liu, Xukai Wang, Bin Tian, Hong Yao, Guangyao Liu","doi":"10.1186/s13018-024-05229-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>To compare the biomechanical outcomes of C1.1 posterior pelvic ring fractures treated with different numbers of LC-II screws and plate internal fixation.</p><p><strong>Materials and methods: </strong>Nine adult preserved pelvic specimens were used. After being measured by bone densitometry, the specimens were randomly divided into 3 groups of 3 pelvic specimens each. The C1.1 pelvic fractures were generated by iliac osteotomies and anterior pelvic ring osteotomies. The fractures were fixed and randomly divided into three groups: (1) one LC-II screw, (2) two LC-II screws, and (3) two reconstruction plates. The anterior pelvic rings were all fixed with pubic branch screws. A biomechanical testing machine loaded all specimens vertically, recording the displacement and ultimate load of the specimens to quantify the stiffness.</p><p><strong>Results: </strong>When loads up to 1000 N were applied, the displacement of the iliac bone was close between the one LC-II screw and the two LC-II screw group specimens; (P > 0.05); when loads such as 1000 N, 1200 N and 1400 N were applied, there was no significant difference in displacement between the plate fixation group and the two LC-II screw fixation group (P > 0.05), both of which were superior to the one LC-II screw fixation group (P < 0.05). There was no significant difference in compressive stiffness between the two LC-II screw fixation groups and the plate fixation group (P > 0.05), and both were superior to the one LC-II screw fixation group (P < 0.05) the ultimate load of both the two LC-II screws and the steel plate is greater than that of one LC-II screw (1.74 times the ultimate load of one LC-II screw for the two LC-II screws and 1.83 times the ultimate load of one LC-II screw for the steel plate).</p><p><strong>Conclusion: </strong>For posterior pelvic ring fractures of type C1.1, placement of two LC-II screws provides comparable posterior pelvic ring stability compared to reconstructed plates. At loads below 1000 N, one LC-II screw fixation and two LC-II screws were comparable in restoring posterior pelvic ring stability.</p>","PeriodicalId":16629,"journal":{"name":"Journal of Orthopaedic Surgery and Research","volume":"19 1","pages":"761"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11566199/pdf/","citationCount":"0","resultStr":"{\"title\":\"Experimental study of fractures of the posterior pelvic ring C1.1 using LC-II screws and internal fixation by plate.\",\"authors\":\"Yu Liu, Xukai Wang, Bin Tian, Hong Yao, Guangyao Liu\",\"doi\":\"10.1186/s13018-024-05229-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>To compare the biomechanical outcomes of C1.1 posterior pelvic ring fractures treated with different numbers of LC-II screws and plate internal fixation.</p><p><strong>Materials and methods: </strong>Nine adult preserved pelvic specimens were used. After being measured by bone densitometry, the specimens were randomly divided into 3 groups of 3 pelvic specimens each. The C1.1 pelvic fractures were generated by iliac osteotomies and anterior pelvic ring osteotomies. The fractures were fixed and randomly divided into three groups: (1) one LC-II screw, (2) two LC-II screws, and (3) two reconstruction plates. The anterior pelvic rings were all fixed with pubic branch screws. A biomechanical testing machine loaded all specimens vertically, recording the displacement and ultimate load of the specimens to quantify the stiffness.</p><p><strong>Results: </strong>When loads up to 1000 N were applied, the displacement of the iliac bone was close between the one LC-II screw and the two LC-II screw group specimens; (P > 0.05); when loads such as 1000 N, 1200 N and 1400 N were applied, there was no significant difference in displacement between the plate fixation group and the two LC-II screw fixation group (P > 0.05), both of which were superior to the one LC-II screw fixation group (P < 0.05). There was no significant difference in compressive stiffness between the two LC-II screw fixation groups and the plate fixation group (P > 0.05), and both were superior to the one LC-II screw fixation group (P < 0.05) the ultimate load of both the two LC-II screws and the steel plate is greater than that of one LC-II screw (1.74 times the ultimate load of one LC-II screw for the two LC-II screws and 1.83 times the ultimate load of one LC-II screw for the steel plate).</p><p><strong>Conclusion: </strong>For posterior pelvic ring fractures of type C1.1, placement of two LC-II screws provides comparable posterior pelvic ring stability compared to reconstructed plates. At loads below 1000 N, one LC-II screw fixation and two LC-II screws were comparable in restoring posterior pelvic ring stability.</p>\",\"PeriodicalId\":16629,\"journal\":{\"name\":\"Journal of Orthopaedic Surgery and Research\",\"volume\":\"19 1\",\"pages\":\"761\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11566199/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Surgery and Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s13018-024-05229-2\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery and Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13018-024-05229-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Experimental study of fractures of the posterior pelvic ring C1.1 using LC-II screws and internal fixation by plate.
Introduction: To compare the biomechanical outcomes of C1.1 posterior pelvic ring fractures treated with different numbers of LC-II screws and plate internal fixation.
Materials and methods: Nine adult preserved pelvic specimens were used. After being measured by bone densitometry, the specimens were randomly divided into 3 groups of 3 pelvic specimens each. The C1.1 pelvic fractures were generated by iliac osteotomies and anterior pelvic ring osteotomies. The fractures were fixed and randomly divided into three groups: (1) one LC-II screw, (2) two LC-II screws, and (3) two reconstruction plates. The anterior pelvic rings were all fixed with pubic branch screws. A biomechanical testing machine loaded all specimens vertically, recording the displacement and ultimate load of the specimens to quantify the stiffness.
Results: When loads up to 1000 N were applied, the displacement of the iliac bone was close between the one LC-II screw and the two LC-II screw group specimens; (P > 0.05); when loads such as 1000 N, 1200 N and 1400 N were applied, there was no significant difference in displacement between the plate fixation group and the two LC-II screw fixation group (P > 0.05), both of which were superior to the one LC-II screw fixation group (P < 0.05). There was no significant difference in compressive stiffness between the two LC-II screw fixation groups and the plate fixation group (P > 0.05), and both were superior to the one LC-II screw fixation group (P < 0.05) the ultimate load of both the two LC-II screws and the steel plate is greater than that of one LC-II screw (1.74 times the ultimate load of one LC-II screw for the two LC-II screws and 1.83 times the ultimate load of one LC-II screw for the steel plate).
Conclusion: For posterior pelvic ring fractures of type C1.1, placement of two LC-II screws provides comparable posterior pelvic ring stability compared to reconstructed plates. At loads below 1000 N, one LC-II screw fixation and two LC-II screws were comparable in restoring posterior pelvic ring stability.
期刊介绍:
Journal of Orthopaedic Surgery and Research is an open access journal that encompasses all aspects of clinical and basic research studies related to musculoskeletal issues.
Orthopaedic research is conducted at clinical and basic science levels. With the advancement of new technologies and the increasing expectation and demand from doctors and patients, we are witnessing an enormous growth in clinical orthopaedic research, particularly in the fields of traumatology, spinal surgery, joint replacement, sports medicine, musculoskeletal tumour management, hand microsurgery, foot and ankle surgery, paediatric orthopaedic, and orthopaedic rehabilitation. The involvement of basic science ranges from molecular, cellular, structural and functional perspectives to tissue engineering, gait analysis, automation and robotic surgery. Implant and biomaterial designs are new disciplines that complement clinical applications.