对送入儿科重症监护室的休克患者进行护理点心脏超声检查的准确性。

IF 1.2 4区 医学 Q3 ACOUSTICS
Suhasini Chico, Sean Connolly, Jobayer Hossain, Yosef Levenbrown
{"title":"对送入儿科重症监护室的休克患者进行护理点心脏超声检查的准确性。","authors":"Suhasini Chico, Sean Connolly, Jobayer Hossain, Yosef Levenbrown","doi":"10.1002/jcu.23883","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess agreement between a novice pediatric critical care fellow's interpretation of left and right ventricular (LV, RV) function using point-of-care ultrasound (POCUS) compared with assessments by pediatric cardiologists and echocardiography.</p><p><strong>Methods: </strong>Echocardiographic clips (parasternal long axis, parasternal short axis, and apical four-chamber) and measurements for LV and RV functions (E-point septal separation, ejection fraction, and tricuspid annular plane systolic excursion) were obtained by PICU fellow in patients 0-18 years old with shock. A pediatric cardiologist reviewed the POCUS images. Agreement between the interpretations by the intensivist, cardiologist, and comprehensive echocardiograms were analyzed using Cohen's kappa.</p><p><strong>Results: </strong>Thirty-one patients were included: 22 had comprehensive echocardiograms. The PICU fellow detected LV dysfunction with 100% sensitivity and > 85% specificity compared with the cardiologist's interpretation and formal echocardiography. Substantial agreement (κ = 0.62) was noted between the intensivist and cardiologist for interpretation of LV function and RV size and pressure (κ = 0.72). The intensivist's assessments showed perfect agreement (κ = 1.0) with echocardiography for LV and RV function. POCUS images ranged from 100% adequate in the parasternal long axis, 90% in the parasternal short axis, and 43% in apical four-chambered views.</p><p><strong>Conclusions: </strong>A novice PICU fellow could reliably use POCUS to assess the cardiac function in pediatric patients with shock.</p>","PeriodicalId":15386,"journal":{"name":"Journal of Clinical Ultrasound","volume":" ","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of Point-Of-Care Cardiac Ultrasound Performed on Patients Admitted to a Pediatric Intensive Care Unit in Shock.\",\"authors\":\"Suhasini Chico, Sean Connolly, Jobayer Hossain, Yosef Levenbrown\",\"doi\":\"10.1002/jcu.23883\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess agreement between a novice pediatric critical care fellow's interpretation of left and right ventricular (LV, RV) function using point-of-care ultrasound (POCUS) compared with assessments by pediatric cardiologists and echocardiography.</p><p><strong>Methods: </strong>Echocardiographic clips (parasternal long axis, parasternal short axis, and apical four-chamber) and measurements for LV and RV functions (E-point septal separation, ejection fraction, and tricuspid annular plane systolic excursion) were obtained by PICU fellow in patients 0-18 years old with shock. A pediatric cardiologist reviewed the POCUS images. Agreement between the interpretations by the intensivist, cardiologist, and comprehensive echocardiograms were analyzed using Cohen's kappa.</p><p><strong>Results: </strong>Thirty-one patients were included: 22 had comprehensive echocardiograms. The PICU fellow detected LV dysfunction with 100% sensitivity and > 85% specificity compared with the cardiologist's interpretation and formal echocardiography. Substantial agreement (κ = 0.62) was noted between the intensivist and cardiologist for interpretation of LV function and RV size and pressure (κ = 0.72). The intensivist's assessments showed perfect agreement (κ = 1.0) with echocardiography for LV and RV function. POCUS images ranged from 100% adequate in the parasternal long axis, 90% in the parasternal short axis, and 43% in apical four-chambered views.</p><p><strong>Conclusions: </strong>A novice PICU fellow could reliably use POCUS to assess the cardiac function in pediatric patients with shock.</p>\",\"PeriodicalId\":15386,\"journal\":{\"name\":\"Journal of Clinical Ultrasound\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Ultrasound\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jcu.23883\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcu.23883","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估儿科重症监护研究员使用床旁超声(POCUS)对左室和右室功能的解释与儿科心脏病专家和超声心动图评估之间的一致性:超声心动图片段(胸骨旁长轴、胸骨旁短轴、心尖四腔)以及左心室和左心室功能测量值(E点室间隔分离、射血分数、三尖瓣环面收缩期偏移)均由儿童重症监护病房研究员为0-18岁休克患者采集。一名儿科心脏病专家审查了 POCUS 图像。采用科恩卡帕(Cohen's kappa)分析了重症监护医师、心脏病专家和综合超声心动图之间的解释是否一致:结果:共纳入 31 名患者:结果:共纳入 31 名患者:22 人进行了综合超声心动图检查。与心脏病专家的解释和正规超声心动图相比,PICU 研究员检测左心室功能障碍的敏感性为 100%,特异性大于 85%。在对左心室功能以及左心室大小和压力的解释方面,重症监护医师和心脏病专家的意见基本一致(κ = 0.62)。在左心室和左心室功能方面,重症监护医师的评估结果与超声心动图完全一致(κ = 1.0)。POCUS图像在胸骨旁长轴的合格率为100%,胸骨旁短轴为90%,心尖四腔切面为43%:结论:PICU 研究员新手可以可靠地使用 POCUS 评估休克儿科患者的心脏功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of Point-Of-Care Cardiac Ultrasound Performed on Patients Admitted to a Pediatric Intensive Care Unit in Shock.

Purpose: To assess agreement between a novice pediatric critical care fellow's interpretation of left and right ventricular (LV, RV) function using point-of-care ultrasound (POCUS) compared with assessments by pediatric cardiologists and echocardiography.

Methods: Echocardiographic clips (parasternal long axis, parasternal short axis, and apical four-chamber) and measurements for LV and RV functions (E-point septal separation, ejection fraction, and tricuspid annular plane systolic excursion) were obtained by PICU fellow in patients 0-18 years old with shock. A pediatric cardiologist reviewed the POCUS images. Agreement between the interpretations by the intensivist, cardiologist, and comprehensive echocardiograms were analyzed using Cohen's kappa.

Results: Thirty-one patients were included: 22 had comprehensive echocardiograms. The PICU fellow detected LV dysfunction with 100% sensitivity and > 85% specificity compared with the cardiologist's interpretation and formal echocardiography. Substantial agreement (κ = 0.62) was noted between the intensivist and cardiologist for interpretation of LV function and RV size and pressure (κ = 0.72). The intensivist's assessments showed perfect agreement (κ = 1.0) with echocardiography for LV and RV function. POCUS images ranged from 100% adequate in the parasternal long axis, 90% in the parasternal short axis, and 43% in apical four-chambered views.

Conclusions: A novice PICU fellow could reliably use POCUS to assess the cardiac function in pediatric patients with shock.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
248
审稿时长
6 months
期刊介绍: The Journal of Clinical Ultrasound (JCU) is an international journal dedicated to the worldwide dissemination of scientific information on diagnostic and therapeutic applications of medical sonography. The scope of the journal includes--but is not limited to--the following areas: sonography of the gastrointestinal tract, genitourinary tract, vascular system, nervous system, head and neck, chest, breast, musculoskeletal system, and other superficial structures; Doppler applications; obstetric and pediatric applications; and interventional sonography. Studies comparing sonography with other imaging modalities are encouraged, as are studies evaluating the economic impact of sonography. Also within the journal''s scope are innovations and improvements in instrumentation and examination techniques and the use of contrast agents. JCU publishes original research articles, case reports, pictorial essays, technical notes, and letters to the editor. The journal is also dedicated to being an educational resource for its readers, through the publication of review articles and various scientific contributions from members of the editorial board and other world-renowned experts in sonography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信