Lajos Bogár, Kamilla Domokos, Csaba Csontos, Balázs Sütő
{"title":"腹腔积气对平均呼气流速的影响:来自健康肺部患者的观察启示","authors":"Lajos Bogár, Kamilla Domokos, Csaba Csontos, Balázs Sütő","doi":"10.3390/diagnostics14212375","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/objectives: </strong>Surgical pneumoperitoneum (PP) significantly impacts volume-controlled ventilation, characterized by reduced respiratory compliance, elevated peak inspiratory pressure, and an accelerated expiratory phase due to an earlier onset of the airway pressure gradient. We hypothesized that this would shorten expiratory time, potentially increasing expiratory flow rate compared to pneumoperitoneum conditions. Calculations were performed to establish correlations between respiratory parameters and the mean increase in expiratory flow rate relative to baseline.</p><p><strong>Methods: </strong>Mechanical ventilation parameters were recorded for 67 patients both pre- and post-PP. Ventilator settings were standardized with a tidal volume of 6 mL/kg, a respiratory rate of 12 breaths per minute, a PEEP of 3 cmH<sub>2</sub>O, an inspiratory time of 2 s, and an inspiratory-to-expiratory ratio of 1:1.5 (I:E).</p><p><strong>Results: </strong>The application of PP increased both peak inspiratory pressure and mean expiratory flow rate by 28% compared to baseline levels. The elevated intra-abdominal pressure of 20 cmH<sub>2</sub>O resulted in a 34% reduction in dynamic chest compliance, a 50% increase in elastance, and a 20% increase in airway resistance. The mean expiratory flow rate increments relative to baseline showed a significant negative correlation with elastance (<i>p</i> = 0.0119) and a positive correlation with dynamic compliance (<i>p</i> = 0.0028) and resistance (<i>p</i> = 0.0240).</p><p><strong>Conclusions: </strong>A PP of 20 cmH<sub>2</sub>O resulted in an increase in the mean expiratory flow rate in the conventional I:E ratio in the volume-ventilated mode. PP reduces lung and chest wall compliance by elevating the diaphragm, compressing the thoracic cavity, and increasing airway pressures. Consequently, the lungs and chest wall stiffen, requiring greater ventilatory effort and accelerating expiratory flow due to increased airway resistance and altered pulmonary mechanics. Prolonging the inspiratory phase through I:E ratio adjustment helps maintain peak inspiratory pressures closer to baseline levels, and this method enhances the safety and efficacy of mechanical ventilation in maintaining optimal respiratory function during laparoscopic surgery.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"14 21","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11544817/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Impact of Pneumoperitoneum on Mean Expiratory Flow Rate: Observational Insights from Patients with Healthy Lungs.\",\"authors\":\"Lajos Bogár, Kamilla Domokos, Csaba Csontos, Balázs Sütő\",\"doi\":\"10.3390/diagnostics14212375\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/objectives: </strong>Surgical pneumoperitoneum (PP) significantly impacts volume-controlled ventilation, characterized by reduced respiratory compliance, elevated peak inspiratory pressure, and an accelerated expiratory phase due to an earlier onset of the airway pressure gradient. We hypothesized that this would shorten expiratory time, potentially increasing expiratory flow rate compared to pneumoperitoneum conditions. Calculations were performed to establish correlations between respiratory parameters and the mean increase in expiratory flow rate relative to baseline.</p><p><strong>Methods: </strong>Mechanical ventilation parameters were recorded for 67 patients both pre- and post-PP. Ventilator settings were standardized with a tidal volume of 6 mL/kg, a respiratory rate of 12 breaths per minute, a PEEP of 3 cmH<sub>2</sub>O, an inspiratory time of 2 s, and an inspiratory-to-expiratory ratio of 1:1.5 (I:E).</p><p><strong>Results: </strong>The application of PP increased both peak inspiratory pressure and mean expiratory flow rate by 28% compared to baseline levels. The elevated intra-abdominal pressure of 20 cmH<sub>2</sub>O resulted in a 34% reduction in dynamic chest compliance, a 50% increase in elastance, and a 20% increase in airway resistance. The mean expiratory flow rate increments relative to baseline showed a significant negative correlation with elastance (<i>p</i> = 0.0119) and a positive correlation with dynamic compliance (<i>p</i> = 0.0028) and resistance (<i>p</i> = 0.0240).</p><p><strong>Conclusions: </strong>A PP of 20 cmH<sub>2</sub>O resulted in an increase in the mean expiratory flow rate in the conventional I:E ratio in the volume-ventilated mode. PP reduces lung and chest wall compliance by elevating the diaphragm, compressing the thoracic cavity, and increasing airway pressures. Consequently, the lungs and chest wall stiffen, requiring greater ventilatory effort and accelerating expiratory flow due to increased airway resistance and altered pulmonary mechanics. Prolonging the inspiratory phase through I:E ratio adjustment helps maintain peak inspiratory pressures closer to baseline levels, and this method enhances the safety and efficacy of mechanical ventilation in maintaining optimal respiratory function during laparoscopic surgery.</p>\",\"PeriodicalId\":11225,\"journal\":{\"name\":\"Diagnostics\",\"volume\":\"14 21\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11544817/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/diagnostics14212375\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics14212375","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
The Impact of Pneumoperitoneum on Mean Expiratory Flow Rate: Observational Insights from Patients with Healthy Lungs.
Background/objectives: Surgical pneumoperitoneum (PP) significantly impacts volume-controlled ventilation, characterized by reduced respiratory compliance, elevated peak inspiratory pressure, and an accelerated expiratory phase due to an earlier onset of the airway pressure gradient. We hypothesized that this would shorten expiratory time, potentially increasing expiratory flow rate compared to pneumoperitoneum conditions. Calculations were performed to establish correlations between respiratory parameters and the mean increase in expiratory flow rate relative to baseline.
Methods: Mechanical ventilation parameters were recorded for 67 patients both pre- and post-PP. Ventilator settings were standardized with a tidal volume of 6 mL/kg, a respiratory rate of 12 breaths per minute, a PEEP of 3 cmH2O, an inspiratory time of 2 s, and an inspiratory-to-expiratory ratio of 1:1.5 (I:E).
Results: The application of PP increased both peak inspiratory pressure and mean expiratory flow rate by 28% compared to baseline levels. The elevated intra-abdominal pressure of 20 cmH2O resulted in a 34% reduction in dynamic chest compliance, a 50% increase in elastance, and a 20% increase in airway resistance. The mean expiratory flow rate increments relative to baseline showed a significant negative correlation with elastance (p = 0.0119) and a positive correlation with dynamic compliance (p = 0.0028) and resistance (p = 0.0240).
Conclusions: A PP of 20 cmH2O resulted in an increase in the mean expiratory flow rate in the conventional I:E ratio in the volume-ventilated mode. PP reduces lung and chest wall compliance by elevating the diaphragm, compressing the thoracic cavity, and increasing airway pressures. Consequently, the lungs and chest wall stiffen, requiring greater ventilatory effort and accelerating expiratory flow due to increased airway resistance and altered pulmonary mechanics. Prolonging the inspiratory phase through I:E ratio adjustment helps maintain peak inspiratory pressures closer to baseline levels, and this method enhances the safety and efficacy of mechanical ventilation in maintaining optimal respiratory function during laparoscopic surgery.
DiagnosticsBiochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍:
Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.