{"title":"通过三尖瓣和二尖瓣开放顺序评估心房颤动患者左心室充盈压的有效性。","authors":"Hisao Nishino, Michito Murayama, Hiroyuki Iwano, Nobuyuki Kagiyama, Yutaka Nakamura, Yuka Akama, Misako Toki, Sachiko Takamatsu, Taiji Okada, Yasuyuki Chiba, Masahiro Nakabachi, Shinobu Yokoyama, Mana Goto, Yukino Suzuki, Suguru Ishizaka, Ko Motoi, Yoji Tamaki, Hiroyuki Aoyagi, Kosuke Nakamura, Sanae Kaga, Chiaki Watanabe, Kiwamu Kamiya, Toshiyuki Nagai, Takanori Teshima, Toshihisa Anzai","doi":"10.1161/CIRCIMAGING.124.017134","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate assessment of left ventricular filling pressure in patients with atrial fibrillation or flutter (AF) remains difficult. A novel 2-dimensional scoring system, visually assessing time difference between mitral valve and tricuspid valve opening (VMT) score, based on temporal analysis of early diastolic valve opening, could be applied to these patients. We aimed to determine the usefulness of the VMT score in patients with AF.</p><p><strong>Methods: </strong>We analyzed 119 consecutive patients with AF who underwent cardiac catheterization as a derivation cohort. The diagnostic performance of the VMT score was further evaluated in an external data set containing 189 patients with AF. Elevated left ventricular filling pressure was defined as a mean pulmonary arterial wedge pressure ≥15 mm Hg. The time sequence of atrioventricular valve opening was visually assessed and scored (0, tricuspid valve first; 1, simultaneous; 2, mitral valve first). When the inferior vena cava was dilated, 1 point was added, and the VMT score was finally graded as 0 to 3. Conventional Doppler parameters to estimate left ventricular filling pressure were also measured.</p><p><strong>Results: </strong>Pulmonary arterial wedge pressure was elevated with an increase in the VMT score (0: 10±3, 1: 13±5, 2: 22±7, 3: 27±6 mm Hg; <i>P</i><0.001), resulting in a significant rise in pulmonary arterial wedge pressure from VMT score 1 to 2. VMT≥2 predicted elevated pulmonary arterial wedge pressure with an accuracy of 87%, and the diagnostic accuracy of the VMT score was significantly higher than that of conventional Doppler parameters (<i>C</i> index, 0.88 versus 0.54-0.68; <i>P</i><0.001). In addition, VMT ≥2 showed an incremental predictive value over plasma brain natriuretic peptide levels (<i>C</i> index, 0.79-0.93; <i>P</i><0.001). In the external validation cohort, VMT≥2 demonstrated acceptable accuracy of 72%.</p><p><strong>Conclusions: </strong>VMT scoring was a useful echocardiographic marker of elevated left ventricular filling pressure and had an incremental benefit over practical biomarkers in patients with AF.</p>","PeriodicalId":10202,"journal":{"name":"Circulation: Cardiovascular Imaging","volume":" ","pages":"e017134"},"PeriodicalIF":6.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11575908/pdf/","citationCount":"0","resultStr":"{\"title\":\"Validation of Left Ventricular Filling Pressure Evaluation by Order of Tricuspid and Mitral Valve Opening in Patients With Atrial Fibrillation.\",\"authors\":\"Hisao Nishino, Michito Murayama, Hiroyuki Iwano, Nobuyuki Kagiyama, Yutaka Nakamura, Yuka Akama, Misako Toki, Sachiko Takamatsu, Taiji Okada, Yasuyuki Chiba, Masahiro Nakabachi, Shinobu Yokoyama, Mana Goto, Yukino Suzuki, Suguru Ishizaka, Ko Motoi, Yoji Tamaki, Hiroyuki Aoyagi, Kosuke Nakamura, Sanae Kaga, Chiaki Watanabe, Kiwamu Kamiya, Toshiyuki Nagai, Takanori Teshima, Toshihisa Anzai\",\"doi\":\"10.1161/CIRCIMAGING.124.017134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Accurate assessment of left ventricular filling pressure in patients with atrial fibrillation or flutter (AF) remains difficult. A novel 2-dimensional scoring system, visually assessing time difference between mitral valve and tricuspid valve opening (VMT) score, based on temporal analysis of early diastolic valve opening, could be applied to these patients. We aimed to determine the usefulness of the VMT score in patients with AF.</p><p><strong>Methods: </strong>We analyzed 119 consecutive patients with AF who underwent cardiac catheterization as a derivation cohort. The diagnostic performance of the VMT score was further evaluated in an external data set containing 189 patients with AF. Elevated left ventricular filling pressure was defined as a mean pulmonary arterial wedge pressure ≥15 mm Hg. The time sequence of atrioventricular valve opening was visually assessed and scored (0, tricuspid valve first; 1, simultaneous; 2, mitral valve first). When the inferior vena cava was dilated, 1 point was added, and the VMT score was finally graded as 0 to 3. Conventional Doppler parameters to estimate left ventricular filling pressure were also measured.</p><p><strong>Results: </strong>Pulmonary arterial wedge pressure was elevated with an increase in the VMT score (0: 10±3, 1: 13±5, 2: 22±7, 3: 27±6 mm Hg; <i>P</i><0.001), resulting in a significant rise in pulmonary arterial wedge pressure from VMT score 1 to 2. VMT≥2 predicted elevated pulmonary arterial wedge pressure with an accuracy of 87%, and the diagnostic accuracy of the VMT score was significantly higher than that of conventional Doppler parameters (<i>C</i> index, 0.88 versus 0.54-0.68; <i>P</i><0.001). In addition, VMT ≥2 showed an incremental predictive value over plasma brain natriuretic peptide levels (<i>C</i> index, 0.79-0.93; <i>P</i><0.001). In the external validation cohort, VMT≥2 demonstrated acceptable accuracy of 72%.</p><p><strong>Conclusions: </strong>VMT scoring was a useful echocardiographic marker of elevated left ventricular filling pressure and had an incremental benefit over practical biomarkers in patients with AF.</p>\",\"PeriodicalId\":10202,\"journal\":{\"name\":\"Circulation: Cardiovascular Imaging\",\"volume\":\" \",\"pages\":\"e017134\"},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11575908/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Circulation: Cardiovascular Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1161/CIRCIMAGING.124.017134\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation: Cardiovascular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCIMAGING.124.017134","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Validation of Left Ventricular Filling Pressure Evaluation by Order of Tricuspid and Mitral Valve Opening in Patients With Atrial Fibrillation.
Background: Accurate assessment of left ventricular filling pressure in patients with atrial fibrillation or flutter (AF) remains difficult. A novel 2-dimensional scoring system, visually assessing time difference between mitral valve and tricuspid valve opening (VMT) score, based on temporal analysis of early diastolic valve opening, could be applied to these patients. We aimed to determine the usefulness of the VMT score in patients with AF.
Methods: We analyzed 119 consecutive patients with AF who underwent cardiac catheterization as a derivation cohort. The diagnostic performance of the VMT score was further evaluated in an external data set containing 189 patients with AF. Elevated left ventricular filling pressure was defined as a mean pulmonary arterial wedge pressure ≥15 mm Hg. The time sequence of atrioventricular valve opening was visually assessed and scored (0, tricuspid valve first; 1, simultaneous; 2, mitral valve first). When the inferior vena cava was dilated, 1 point was added, and the VMT score was finally graded as 0 to 3. Conventional Doppler parameters to estimate left ventricular filling pressure were also measured.
Results: Pulmonary arterial wedge pressure was elevated with an increase in the VMT score (0: 10±3, 1: 13±5, 2: 22±7, 3: 27±6 mm Hg; P<0.001), resulting in a significant rise in pulmonary arterial wedge pressure from VMT score 1 to 2. VMT≥2 predicted elevated pulmonary arterial wedge pressure with an accuracy of 87%, and the diagnostic accuracy of the VMT score was significantly higher than that of conventional Doppler parameters (C index, 0.88 versus 0.54-0.68; P<0.001). In addition, VMT ≥2 showed an incremental predictive value over plasma brain natriuretic peptide levels (C index, 0.79-0.93; P<0.001). In the external validation cohort, VMT≥2 demonstrated acceptable accuracy of 72%.
Conclusions: VMT scoring was a useful echocardiographic marker of elevated left ventricular filling pressure and had an incremental benefit over practical biomarkers in patients with AF.
期刊介绍:
Circulation: Cardiovascular Imaging, an American Heart Association journal, publishes high-quality, patient-centric articles focusing on observational studies, clinical trials, and advances in applied (translational) research. The journal features innovative, multimodality approaches to the diagnosis and risk stratification of cardiovascular disease. Modalities covered include echocardiography, cardiac computed tomography, cardiac magnetic resonance imaging and spectroscopy, magnetic resonance angiography, cardiac positron emission tomography, noninvasive assessment of vascular and endothelial function, radionuclide imaging, molecular imaging, and others.
Article types considered by Circulation: Cardiovascular Imaging include Original Research, Research Letters, Advances in Cardiovascular Imaging, Clinical Implications of Molecular Imaging Research, How to Use Imaging, Translating Novel Imaging Technologies into Clinical Applications, and Cardiovascular Images.