上颌无牙传统印模法与数字印模法的比较:临床研究。

IF 2.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Sinem Kahya Karaca, Kıvanc Akca
{"title":"上颌无牙传统印模法与数字印模法的比较:临床研究。","authors":"Sinem Kahya Karaca, Kıvanc Akca","doi":"10.1186/s12903-024-05151-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The expectations for the clinical and laboratory phases of tissue-supported complete dentures (TSCDs) are changing. Currently, there is a trend towards fast, comfortable, reliable, and low-cost methods. In TSCD impressions, simplified impression and digital impression methods involving the use of an intraoral scanner (IOS) are becoming preferable. Given this situation, this study aims to compare different conventional and digital impression methods used in TSCDs.</p><p><strong>Methods: </strong>Patients with maxillary complete edentulism and healthy oral mucosa were included in this study. In the digital group, two different impressions were made using an IOS (Trios4) without (D1) and with (D2) artificial intelligence scanning (AI-Scan). In addition, a modified impression (D3) was made using the IOS in two steps, including the occlusal rim. In the conventional group, a two-step impression (C1) using an individual tray with zinc oxide eugenol and a one-step simplified impression (C2) using a stock tray with irreversible hydrocolloid were made. The comparison groups were determined to be C1-C2, C1-D1, D1-D2, and D1-D3. The best-fit algorithm was used to superimpose the impressions to be compared. The right and left vestibular areas, postdam area, palatal area, right and left matching area, entire surface, and borders were evaluated separately.</p><p><strong>Results: </strong>Fifteen patients were included in this study. In the C1-C2 group, the mean deviation at the borders was statistically significant (p = 0.01). No regions in the C1-D1 and D1-D3 groups exhibited significant differences in the mean amount of deviation (p > 0,05). In the D1-D2 group, the mean deviation in the palatal area was significant (p = 0,03).</p><p><strong>Conclusion: </strong>In maxillary edentulism, digital impressions have shown comparable results to conventional impressions, suggesting promising implications for clinical applications.</p><p><strong>Trial registration: </strong>The clinical trial has been registered (ClinicalTrials.gov ID NCT06400277, registration date 06/05/2024, 'retrospectively registered').</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"24 1","pages":"1378"},"PeriodicalIF":2.6000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11566592/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of conventional and digital impression approaches for edentulous maxilla: clinical study.\",\"authors\":\"Sinem Kahya Karaca, Kıvanc Akca\",\"doi\":\"10.1186/s12903-024-05151-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The expectations for the clinical and laboratory phases of tissue-supported complete dentures (TSCDs) are changing. Currently, there is a trend towards fast, comfortable, reliable, and low-cost methods. In TSCD impressions, simplified impression and digital impression methods involving the use of an intraoral scanner (IOS) are becoming preferable. Given this situation, this study aims to compare different conventional and digital impression methods used in TSCDs.</p><p><strong>Methods: </strong>Patients with maxillary complete edentulism and healthy oral mucosa were included in this study. In the digital group, two different impressions were made using an IOS (Trios4) without (D1) and with (D2) artificial intelligence scanning (AI-Scan). In addition, a modified impression (D3) was made using the IOS in two steps, including the occlusal rim. In the conventional group, a two-step impression (C1) using an individual tray with zinc oxide eugenol and a one-step simplified impression (C2) using a stock tray with irreversible hydrocolloid were made. The comparison groups were determined to be C1-C2, C1-D1, D1-D2, and D1-D3. The best-fit algorithm was used to superimpose the impressions to be compared. The right and left vestibular areas, postdam area, palatal area, right and left matching area, entire surface, and borders were evaluated separately.</p><p><strong>Results: </strong>Fifteen patients were included in this study. In the C1-C2 group, the mean deviation at the borders was statistically significant (p = 0.01). No regions in the C1-D1 and D1-D3 groups exhibited significant differences in the mean amount of deviation (p > 0,05). In the D1-D2 group, the mean deviation in the palatal area was significant (p = 0,03).</p><p><strong>Conclusion: </strong>In maxillary edentulism, digital impressions have shown comparable results to conventional impressions, suggesting promising implications for clinical applications.</p><p><strong>Trial registration: </strong>The clinical trial has been registered (ClinicalTrials.gov ID NCT06400277, registration date 06/05/2024, 'retrospectively registered').</p>\",\"PeriodicalId\":9072,\"journal\":{\"name\":\"BMC Oral Health\",\"volume\":\"24 1\",\"pages\":\"1378\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11566592/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Oral Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12903-024-05151-3\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-024-05151-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:人们对组织支持全口义齿(TSCD)的临床和实验室阶段的期望正在发生变化。目前的趋势是采用快速、舒适、可靠和低成本的方法。在全口义齿印模中,使用口内扫描仪(IOS)的简化印模和数字印模方法正变得越来越受欢迎。鉴于这种情况,本研究旨在比较TSCD中使用的不同传统和数字印模方法:研究对象包括上颌完全缺牙且口腔粘膜健康的患者。在数字化组中,使用 IOS(Trios4)制作了两种不同的印模,分别不使用人工智能扫描(AI-Scan)(D1)和使用人工智能扫描(AI-Scan)(D2)。此外,还使用 IOS 分两步制作了一个改良印模(D3),包括咬合缘。在传统组中,使用带有氧化锌丁香酚的独立托盘制作两步印模(C1),使用带有不可逆水胶体的库存托盘制作一步简化印模(C2)。比较组分别为 C1-C2、C1-D1、D1-D2 和 D1-D3。使用最佳拟合算法叠加要比较的印模。分别评估了左右前庭区、后潭区、腭区、左右匹配区、整个表面和边界:本研究共纳入 15 名患者。在 C1-C2 组中,边界的平均偏差具有统计学意义(P = 0.01)。C1-D1 组和 D1-D3 组的平均偏差量无明显差异(P > 0.05)。在 D1-D2 组中,腭部的平均偏差显著(p = 0.03):结论:在上颌龋齿治疗中,数字印模的效果与传统印模相当,这表明数字印模在临床应用中大有可为:该临床试验已注册(ClinicalTrials.gov ID NCT06400277,注册日期为 06/05/2024,"回顾性注册")。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of conventional and digital impression approaches for edentulous maxilla: clinical study.

Background: The expectations for the clinical and laboratory phases of tissue-supported complete dentures (TSCDs) are changing. Currently, there is a trend towards fast, comfortable, reliable, and low-cost methods. In TSCD impressions, simplified impression and digital impression methods involving the use of an intraoral scanner (IOS) are becoming preferable. Given this situation, this study aims to compare different conventional and digital impression methods used in TSCDs.

Methods: Patients with maxillary complete edentulism and healthy oral mucosa were included in this study. In the digital group, two different impressions were made using an IOS (Trios4) without (D1) and with (D2) artificial intelligence scanning (AI-Scan). In addition, a modified impression (D3) was made using the IOS in two steps, including the occlusal rim. In the conventional group, a two-step impression (C1) using an individual tray with zinc oxide eugenol and a one-step simplified impression (C2) using a stock tray with irreversible hydrocolloid were made. The comparison groups were determined to be C1-C2, C1-D1, D1-D2, and D1-D3. The best-fit algorithm was used to superimpose the impressions to be compared. The right and left vestibular areas, postdam area, palatal area, right and left matching area, entire surface, and borders were evaluated separately.

Results: Fifteen patients were included in this study. In the C1-C2 group, the mean deviation at the borders was statistically significant (p = 0.01). No regions in the C1-D1 and D1-D3 groups exhibited significant differences in the mean amount of deviation (p > 0,05). In the D1-D2 group, the mean deviation in the palatal area was significant (p = 0,03).

Conclusion: In maxillary edentulism, digital impressions have shown comparable results to conventional impressions, suggesting promising implications for clinical applications.

Trial registration: The clinical trial has been registered (ClinicalTrials.gov ID NCT06400277, registration date 06/05/2024, 'retrospectively registered').

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信