Amelework Wodajo, Ravi Sarode, Nicole De Simone, Vaidehi Kaza, Amena Usmani
{"title":"治疗性血浆置换和 IVIG 标准方案治疗肺移植受者抗体介导的排斥反应的疗效。","authors":"Amelework Wodajo, Ravi Sarode, Nicole De Simone, Vaidehi Kaza, Amena Usmani","doi":"10.1002/jca.22151","DOIUrl":null,"url":null,"abstract":"<p>Antibody-mediated rejection (AMR) in lung transplantation has been associated with poor long-term clinical course and is a risk factor for chronic lung allograft dysfunction and graft loss. Appropriate management of AMR is necessary to improve graft survival in lung transplant recipients. There is currently no standardized approach to the treatment of lung AMR, and practices vary by institution. We sought to examine the efficacy of a standardized protocol of plasma exchange (PLEX) and IVIG in decreasing donor-specific antibodies (DSAs) and improving AMR in lung transplant recipients. A retrospective chart review was conducted on all lung transplant recipients who completed a course of PLEX per UT Southwestern AMR protocol between January 2012 and December 2019 for diagnosis of AMR. Data were collected on the patient clinical course, treatment regimen, pre-PLEX DSA, post-PLEX DSA, follow-up (> 1-month post-PLEX) DSA, and pre-and post-PLEX biopsy, when available. Of 527 patients who underwent lung transplantation during the study period, 56 (11%) received an acute course of PLEX every other day per protocol for AMR of lung transplant. Forty (71%) of 56 patients had one episode of AMR requiring PLEX; 16 patients (29%) had repeat episodes of AMR within 6 weeks to 47 months of the first episode. Most patients showed improvement in AMR on biopsy (69%) and a decline in DSA (68%). Our data suggest that treatment with combined PLEX and IVIG protocol appears effective for treating lung AMR.</p>","PeriodicalId":15390,"journal":{"name":"Journal of Clinical Apheresis","volume":"39 6","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jca.22151","citationCount":"0","resultStr":"{\"title\":\"Efficacy of a Standardized Regimen of Therapeutic Plasma Exchange and IVIG for Treatment of Antibody-Mediated Rejection in Lung Transplant Recipients\",\"authors\":\"Amelework Wodajo, Ravi Sarode, Nicole De Simone, Vaidehi Kaza, Amena Usmani\",\"doi\":\"10.1002/jca.22151\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Antibody-mediated rejection (AMR) in lung transplantation has been associated with poor long-term clinical course and is a risk factor for chronic lung allograft dysfunction and graft loss. Appropriate management of AMR is necessary to improve graft survival in lung transplant recipients. There is currently no standardized approach to the treatment of lung AMR, and practices vary by institution. We sought to examine the efficacy of a standardized protocol of plasma exchange (PLEX) and IVIG in decreasing donor-specific antibodies (DSAs) and improving AMR in lung transplant recipients. A retrospective chart review was conducted on all lung transplant recipients who completed a course of PLEX per UT Southwestern AMR protocol between January 2012 and December 2019 for diagnosis of AMR. Data were collected on the patient clinical course, treatment regimen, pre-PLEX DSA, post-PLEX DSA, follow-up (> 1-month post-PLEX) DSA, and pre-and post-PLEX biopsy, when available. Of 527 patients who underwent lung transplantation during the study period, 56 (11%) received an acute course of PLEX every other day per protocol for AMR of lung transplant. Forty (71%) of 56 patients had one episode of AMR requiring PLEX; 16 patients (29%) had repeat episodes of AMR within 6 weeks to 47 months of the first episode. Most patients showed improvement in AMR on biopsy (69%) and a decline in DSA (68%). Our data suggest that treatment with combined PLEX and IVIG protocol appears effective for treating lung AMR.</p>\",\"PeriodicalId\":15390,\"journal\":{\"name\":\"Journal of Clinical Apheresis\",\"volume\":\"39 6\",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jca.22151\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Apheresis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jca.22151\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Apheresis","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jca.22151","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
肺移植中抗体介导的排斥反应(AMR)与不良的长期临床过程有关,是导致慢性肺异体移植功能障碍和移植物丢失的危险因素。要提高肺移植受者的移植物存活率,就必须对 AMR 进行适当处理。目前还没有治疗肺AMR的标准化方法,各机构的做法也不尽相同。我们试图研究血浆置换(PLEX)和 IVIG 标准化方案在降低供体特异性抗体(DSAs)和改善肺移植受者 AMR 方面的疗效。我们对 2012 年 1 月至 2019 年 12 月期间因确诊 AMR 而按照UT Southwestern AMR 方案完成 PLEX 疗程的所有肺移植受者进行了回顾性病历审查。收集的数据包括患者的临床病程、治疗方案、PLEX 前 DSA、PLEX 后 DSA、随访(PLEX 后 1 个月后)DSA 以及 PLEX 前和 PLEX 后活检(如有)。在研究期间接受肺移植手术的 527 名患者中,有 56 人(11%)按照肺移植 AMR 协议接受了隔天一次的 PLEX 急性疗程。56名患者中有40名(71%)曾发生过一次需要PLEX的AMR;16名患者(29%)在第一次AMR发生后的6周至47个月内再次发生了AMR。大多数患者的活检结果显示 AMR 有所改善(69%),DSA 有所下降(68%)。我们的数据表明,联合使用 PLEX 和 IVIG 方案治疗肺部 AMR 似乎很有效。
Efficacy of a Standardized Regimen of Therapeutic Plasma Exchange and IVIG for Treatment of Antibody-Mediated Rejection in Lung Transplant Recipients
Antibody-mediated rejection (AMR) in lung transplantation has been associated with poor long-term clinical course and is a risk factor for chronic lung allograft dysfunction and graft loss. Appropriate management of AMR is necessary to improve graft survival in lung transplant recipients. There is currently no standardized approach to the treatment of lung AMR, and practices vary by institution. We sought to examine the efficacy of a standardized protocol of plasma exchange (PLEX) and IVIG in decreasing donor-specific antibodies (DSAs) and improving AMR in lung transplant recipients. A retrospective chart review was conducted on all lung transplant recipients who completed a course of PLEX per UT Southwestern AMR protocol between January 2012 and December 2019 for diagnosis of AMR. Data were collected on the patient clinical course, treatment regimen, pre-PLEX DSA, post-PLEX DSA, follow-up (> 1-month post-PLEX) DSA, and pre-and post-PLEX biopsy, when available. Of 527 patients who underwent lung transplantation during the study period, 56 (11%) received an acute course of PLEX every other day per protocol for AMR of lung transplant. Forty (71%) of 56 patients had one episode of AMR requiring PLEX; 16 patients (29%) had repeat episodes of AMR within 6 weeks to 47 months of the first episode. Most patients showed improvement in AMR on biopsy (69%) and a decline in DSA (68%). Our data suggest that treatment with combined PLEX and IVIG protocol appears effective for treating lung AMR.
期刊介绍:
The Journal of Clinical Apheresis publishes articles dealing with all aspects of hemapheresis. Articles welcomed for review include those reporting basic research and clinical applications of therapeutic plasma exchange, therapeutic cytapheresis, therapeutic absorption, blood component collection and transfusion, donor recruitment and safety, administration of hemapheresis centers, and innovative applications of hemapheresis technology. Experimental studies, clinical trials, case reports, and concise reviews will be welcomed.