利用三维无标记运动捕捉技术,评估大样本人群的落点垂直跳跃运动学和动力学。

IF 4.3 3区 工程技术 Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY
Frontiers in Bioengineering and Biotechnology Pub Date : 2024-10-24 eCollection Date: 2024-01-01 DOI:10.3389/fbioe.2024.1426677
Tylan Templin, Christopher D Riehm, Travis Eliason, Tessa C Hulburt, Samuel T Kwak, Omar Medjaouri, David Chambers, Manish Anand, Kase Saylor, Gregory D Myer, Daniel P Nicolella
{"title":"利用三维无标记运动捕捉技术,评估大样本人群的落点垂直跳跃运动学和动力学。","authors":"Tylan Templin, Christopher D Riehm, Travis Eliason, Tessa C Hulburt, Samuel T Kwak, Omar Medjaouri, David Chambers, Manish Anand, Kase Saylor, Gregory D Myer, Daniel P Nicolella","doi":"10.3389/fbioe.2024.1426677","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>3D Markerless motion capture technologies have advanced significantly over the last few decades to overcome limitations of marker-based systems, which require significant cost, time, and specialization. As markerless motion capture technologies develop and mature, there is increasing demand from the biomechanics community to provide kinematic and kinetic data with similar levels of reliability and accuracy as current reference standard marker-based 3D motion capture methods. The purpose of this study was to evaluate how a novel markerless system trained with both hand-labeled and synthetic data compares to lower extremity kinematic and kinetic measurements from a reference marker-based system during the drop vertical jump (DVJ) task.</p><p><strong>Methods: </strong>Synchronized video data from multiple camera views and marker-based data were simultaneously collected from 127 participants performing three repetitions of the DVJ. Lower limb joint angles and joint moments were calculated and compared between the markerless and marker-based systems. Root mean squared error values and Pearson correlation coefficients were used to quantify agreement between the systems.</p><p><strong>Results: </strong>Root mean squared error values of lower limb joint angles and joint moments were ≤ 9.61 degrees and ≤ 0.23 N×m/kg, respectively. Pearson correlation values between markered and markerless systems were 0.67-0.98 hip, 0.45-0.99 knee and 0.06-0.99 ankle for joint kinematics. Likewise, Pearson correlation values were 0.73-0.90 hip, 0.61-0.95 knee and 0.74-0.95 ankle for joint kinetics.</p><p><strong>Discussion: </strong>These results highlight the promising potential of markerless motion capture, particularly for measures of hip, knee and ankle rotations. Further research is needed to evaluate the viability of markerless ankle measures in the frontal plane to determine if differences in joint solvers are inducing unanticipated error.</p>","PeriodicalId":12444,"journal":{"name":"Frontiers in Bioengineering and Biotechnology","volume":"12 ","pages":"1426677"},"PeriodicalIF":4.3000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11540714/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of drop vertical jump kinematics and kinetics using 3D markerless motion capture in a large cohort.\",\"authors\":\"Tylan Templin, Christopher D Riehm, Travis Eliason, Tessa C Hulburt, Samuel T Kwak, Omar Medjaouri, David Chambers, Manish Anand, Kase Saylor, Gregory D Myer, Daniel P Nicolella\",\"doi\":\"10.3389/fbioe.2024.1426677\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>3D Markerless motion capture technologies have advanced significantly over the last few decades to overcome limitations of marker-based systems, which require significant cost, time, and specialization. As markerless motion capture technologies develop and mature, there is increasing demand from the biomechanics community to provide kinematic and kinetic data with similar levels of reliability and accuracy as current reference standard marker-based 3D motion capture methods. The purpose of this study was to evaluate how a novel markerless system trained with both hand-labeled and synthetic data compares to lower extremity kinematic and kinetic measurements from a reference marker-based system during the drop vertical jump (DVJ) task.</p><p><strong>Methods: </strong>Synchronized video data from multiple camera views and marker-based data were simultaneously collected from 127 participants performing three repetitions of the DVJ. Lower limb joint angles and joint moments were calculated and compared between the markerless and marker-based systems. Root mean squared error values and Pearson correlation coefficients were used to quantify agreement between the systems.</p><p><strong>Results: </strong>Root mean squared error values of lower limb joint angles and joint moments were ≤ 9.61 degrees and ≤ 0.23 N×m/kg, respectively. Pearson correlation values between markered and markerless systems were 0.67-0.98 hip, 0.45-0.99 knee and 0.06-0.99 ankle for joint kinematics. Likewise, Pearson correlation values were 0.73-0.90 hip, 0.61-0.95 knee and 0.74-0.95 ankle for joint kinetics.</p><p><strong>Discussion: </strong>These results highlight the promising potential of markerless motion capture, particularly for measures of hip, knee and ankle rotations. Further research is needed to evaluate the viability of markerless ankle measures in the frontal plane to determine if differences in joint solvers are inducing unanticipated error.</p>\",\"PeriodicalId\":12444,\"journal\":{\"name\":\"Frontiers in Bioengineering and Biotechnology\",\"volume\":\"12 \",\"pages\":\"1426677\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11540714/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in Bioengineering and Biotechnology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3389/fbioe.2024.1426677\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Bioengineering and Biotechnology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3389/fbioe.2024.1426677","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导言:无标记三维运动捕捉技术在过去几十年中取得了长足的进步,克服了基于标记系统的局限性,因为基于标记系统需要大量的成本、时间和专业化。随着无标记运动捕捉技术的发展和成熟,生物力学界对提供运动学和动力学数据的要求越来越高,这些数据的可靠性和准确性应与当前基于标记的三维运动捕捉方法的参考标准相当。本研究的目的是评估一种新型无标记系统与基于标记的参考系统在垂体垂直跳(DVJ)任务中的下肢运动学和动力学测量结果的比较:方法: 同时收集了 127 名参与者在进行三次下蹲纵跳任务时来自多个摄像机视角的同步视频数据和基于标记的数据。计算下肢关节角度和关节力矩,并在无标记系统和有标记系统之间进行比较。使用均方根误差值和皮尔逊相关系数来量化系统之间的一致性:下肢关节角度和关节力矩的均方根误差值分别为≤9.61度和≤0.23 N×m/kg。在关节运动学方面,有标记和无标记系统之间的皮尔逊相关值分别为:髋关节 0.67-0.98,膝关节 0.45-0.99,踝关节 0.06-0.99。同样,在关节运动学方面,髋关节、膝关节和踝关节的皮尔逊相关值分别为 0.73-0.90 、0.61-0.95 和 0.74-0.95:这些结果凸显了无标记运动捕捉的巨大潜力,尤其是在测量髋关节、膝关节和踝关节旋转方面。还需要进一步研究,以评估无标记踝关节在正面测量的可行性,从而确定关节解算器的差异是否会导致意料之外的误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of drop vertical jump kinematics and kinetics using 3D markerless motion capture in a large cohort.

Introduction: 3D Markerless motion capture technologies have advanced significantly over the last few decades to overcome limitations of marker-based systems, which require significant cost, time, and specialization. As markerless motion capture technologies develop and mature, there is increasing demand from the biomechanics community to provide kinematic and kinetic data with similar levels of reliability and accuracy as current reference standard marker-based 3D motion capture methods. The purpose of this study was to evaluate how a novel markerless system trained with both hand-labeled and synthetic data compares to lower extremity kinematic and kinetic measurements from a reference marker-based system during the drop vertical jump (DVJ) task.

Methods: Synchronized video data from multiple camera views and marker-based data were simultaneously collected from 127 participants performing three repetitions of the DVJ. Lower limb joint angles and joint moments were calculated and compared between the markerless and marker-based systems. Root mean squared error values and Pearson correlation coefficients were used to quantify agreement between the systems.

Results: Root mean squared error values of lower limb joint angles and joint moments were ≤ 9.61 degrees and ≤ 0.23 N×m/kg, respectively. Pearson correlation values between markered and markerless systems were 0.67-0.98 hip, 0.45-0.99 knee and 0.06-0.99 ankle for joint kinematics. Likewise, Pearson correlation values were 0.73-0.90 hip, 0.61-0.95 knee and 0.74-0.95 ankle for joint kinetics.

Discussion: These results highlight the promising potential of markerless motion capture, particularly for measures of hip, knee and ankle rotations. Further research is needed to evaluate the viability of markerless ankle measures in the frontal plane to determine if differences in joint solvers are inducing unanticipated error.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Frontiers in Bioengineering and Biotechnology
Frontiers in Bioengineering and Biotechnology Chemical Engineering-Bioengineering
CiteScore
8.30
自引率
5.30%
发文量
2270
审稿时长
12 weeks
期刊介绍: The translation of new discoveries in medicine to clinical routine has never been easy. During the second half of the last century, thanks to the progress in chemistry, biochemistry and pharmacology, we have seen the development and the application of a large number of drugs and devices aimed at the treatment of symptoms, blocking unwanted pathways and, in the case of infectious diseases, fighting the micro-organisms responsible. However, we are facing, today, a dramatic change in the therapeutic approach to pathologies and diseases. Indeed, the challenge of the present and the next decade is to fully restore the physiological status of the diseased organism and to completely regenerate tissue and organs when they are so seriously affected that treatments cannot be limited to the repression of symptoms or to the repair of damage. This is being made possible thanks to the major developments made in basic cell and molecular biology, including stem cell science, growth factor delivery, gene isolation and transfection, the advances in bioengineering and nanotechnology, including development of new biomaterials, biofabrication technologies and use of bioreactors, and the big improvements in diagnostic tools and imaging of cells, tissues and organs. In today`s world, an enhancement of communication between multidisciplinary experts, together with the promotion of joint projects and close collaborations among scientists, engineers, industry people, regulatory agencies and physicians are absolute requirements for the success of any attempt to develop and clinically apply a new biological therapy or an innovative device involving the collective use of biomaterials, cells and/or bioactive molecules. “Frontiers in Bioengineering and Biotechnology” aspires to be a forum for all people involved in the process by bridging the gap too often existing between a discovery in the basic sciences and its clinical application.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信