腰椎间盘经皮后外侧经椎间孔内窥镜手术的 Kambin 三角区解剖学评估:一项基于磁共振成像的研究。

IF 1.4 Q3 ANATOMY & MORPHOLOGY
Naeeme Nikpour, Zahra Fazelinejad, Mozhgan Sametzadeh, Mohammad Ardeshiri Lordjani, Ali Reza Eftekhari Moghadam
{"title":"腰椎间盘经皮后外侧经椎间孔内窥镜手术的 Kambin 三角区解剖学评估:一项基于磁共振成像的研究。","authors":"Naeeme Nikpour, Zahra Fazelinejad, Mozhgan Sametzadeh, Mohammad Ardeshiri Lordjani, Ali Reza Eftekhari Moghadam","doi":"10.5115/acb.24.112","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of the present study was to utilize magnetic resonance imaging (MRI) as a noninvasive tool for evaluation of the Kambin's triangle safe zone. Lumbar MRIs of 67 healthy subjects were analyzed. On the coronal plane, the distance from the superior endplate to the nerve root exiting from the dura (distance a), the distance from the lateral aspect of the dura to the medial aspect of the nerve root (distance b), and the angle between the nerve root and plane of the corresponding disc (angle α) was measured. On the axial plane, the vertical distance from the upper facet surface to the exiting nerve root and root-disc distance was also measured. On the sagittal plane, foraminal height, diameter, nerve root-disc distance, and nerve root-pedicle distance were measured. On the coronal plane, right and left α angle was 50.78±4.43 (range, 48.52-51.84 degrees) and 51.07±4.08 (range, 49.25-51.91) degrees, respectively. Distance of right 'a' was 17.86±3.86 mm (range, 10.56-24.84 mm) and left 'a' was 18.03±3.73 mm (range, 10.98-24.82 mm), distance of right 'b' was 15.57±2.61 mm (range, 10.54-20.70 mm) and left 'b' was 15.46±2.68 mm (range, 10.93-19.23 mm). All these measurements increased as the spine level went down. Foraminal height and diameter decreased caudally. Nerve root-facet distance did not show change as the level went down. The study indicated that radiologic measurement is feasible to evaluate the anatomy of the Kambin's triangle. At lower lumbar levels, the exiting nerve root is at risk of injury.</p>","PeriodicalId":7831,"journal":{"name":"Anatomy & Cell Biology","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Anatomical assessment of the Kambin's triangle for percutaneous posterolateral transforaminal endoscopic surgery of lumbar intervertebral discs: a magnetic resonance imaging based study.\",\"authors\":\"Naeeme Nikpour, Zahra Fazelinejad, Mozhgan Sametzadeh, Mohammad Ardeshiri Lordjani, Ali Reza Eftekhari Moghadam\",\"doi\":\"10.5115/acb.24.112\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of the present study was to utilize magnetic resonance imaging (MRI) as a noninvasive tool for evaluation of the Kambin's triangle safe zone. Lumbar MRIs of 67 healthy subjects were analyzed. On the coronal plane, the distance from the superior endplate to the nerve root exiting from the dura (distance a), the distance from the lateral aspect of the dura to the medial aspect of the nerve root (distance b), and the angle between the nerve root and plane of the corresponding disc (angle α) was measured. On the axial plane, the vertical distance from the upper facet surface to the exiting nerve root and root-disc distance was also measured. On the sagittal plane, foraminal height, diameter, nerve root-disc distance, and nerve root-pedicle distance were measured. On the coronal plane, right and left α angle was 50.78±4.43 (range, 48.52-51.84 degrees) and 51.07±4.08 (range, 49.25-51.91) degrees, respectively. Distance of right 'a' was 17.86±3.86 mm (range, 10.56-24.84 mm) and left 'a' was 18.03±3.73 mm (range, 10.98-24.82 mm), distance of right 'b' was 15.57±2.61 mm (range, 10.54-20.70 mm) and left 'b' was 15.46±2.68 mm (range, 10.93-19.23 mm). All these measurements increased as the spine level went down. Foraminal height and diameter decreased caudally. Nerve root-facet distance did not show change as the level went down. The study indicated that radiologic measurement is feasible to evaluate the anatomy of the Kambin's triangle. At lower lumbar levels, the exiting nerve root is at risk of injury.</p>\",\"PeriodicalId\":7831,\"journal\":{\"name\":\"Anatomy & Cell Biology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anatomy & Cell Biology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5115/acb.24.112\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ANATOMY & MORPHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anatomy & Cell Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5115/acb.24.112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在利用磁共振成像(MRI)作为评估坎宾三角安全区的无创工具。研究分析了 67 名健康受试者的腰椎磁共振成像。在冠状面上,测量了从上终板到神经根出硬膜的距离(距离 a)、从硬膜外侧到神经根内侧的距离(距离 b)以及神经根与相应椎间盘平面之间的夹角(夹角 α)。在轴向平面上,还测量了从上切面表面到神经根出口的垂直距离以及神经根与椎间盘之间的距离。在矢状面上,测量了椎管高度、直径、神经根-椎间盘距离和神经根-椎弓根距离。在冠状面上,左右α角分别为 50.78±4.43(范围,48.52-51.84 度)和 51.07±4.08(范围,49.25-51.91 度)度。右侧 "a "的距离为 17.86±3.86毫米(范围为 10.56-24.84毫米),左侧 "a "的距离为 18.03±3.73毫米(范围为 10.98-24.82毫米);右侧 "b "的距离为 15.57±2.61毫米(范围为 10.54-20.70毫米),左侧 "b "的距离为 15.46±2.68毫米(范围为 10.93-19.23毫米)。所有这些测量值都随着脊柱水平的下降而增加。神经孔的高度和直径向尾部减小。神经根与面的距离没有随着脊柱水平的下降而发生变化。该研究表明,用放射学测量方法评估坎宾三角区的解剖结构是可行的。在较低的腰椎水平,出椎神经根有受伤的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Anatomical assessment of the Kambin's triangle for percutaneous posterolateral transforaminal endoscopic surgery of lumbar intervertebral discs: a magnetic resonance imaging based study.

The aim of the present study was to utilize magnetic resonance imaging (MRI) as a noninvasive tool for evaluation of the Kambin's triangle safe zone. Lumbar MRIs of 67 healthy subjects were analyzed. On the coronal plane, the distance from the superior endplate to the nerve root exiting from the dura (distance a), the distance from the lateral aspect of the dura to the medial aspect of the nerve root (distance b), and the angle between the nerve root and plane of the corresponding disc (angle α) was measured. On the axial plane, the vertical distance from the upper facet surface to the exiting nerve root and root-disc distance was also measured. On the sagittal plane, foraminal height, diameter, nerve root-disc distance, and nerve root-pedicle distance were measured. On the coronal plane, right and left α angle was 50.78±4.43 (range, 48.52-51.84 degrees) and 51.07±4.08 (range, 49.25-51.91) degrees, respectively. Distance of right 'a' was 17.86±3.86 mm (range, 10.56-24.84 mm) and left 'a' was 18.03±3.73 mm (range, 10.98-24.82 mm), distance of right 'b' was 15.57±2.61 mm (range, 10.54-20.70 mm) and left 'b' was 15.46±2.68 mm (range, 10.93-19.23 mm). All these measurements increased as the spine level went down. Foraminal height and diameter decreased caudally. Nerve root-facet distance did not show change as the level went down. The study indicated that radiologic measurement is feasible to evaluate the anatomy of the Kambin's triangle. At lower lumbar levels, the exiting nerve root is at risk of injury.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Anatomy & Cell Biology
Anatomy & Cell Biology ANATOMY & MORPHOLOGY-
CiteScore
1.80
自引率
9.10%
发文量
75
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信