在不同培养基中输送的 DSAEK 手术切口组织和预切口组织的移植物脱落率。

IF 3 3区 医学 Q1 OPHTHALMOLOGY
Thorbjörg Olafsdottir, Faisal Hootak, Carina Forslund, Eydis Olafsdottir, Ingemar Gustafsson
{"title":"在不同培养基中输送的 DSAEK 手术切口组织和预切口组织的移植物脱落率。","authors":"Thorbjörg Olafsdottir, Faisal Hootak, Carina Forslund, Eydis Olafsdottir, Ingemar Gustafsson","doi":"10.1111/aos.16791","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyse graft detachment rates after Descemet stripping automated endothelial keratoplasty (DSAEK) using surgeon-cut grafts and pre-cut grafts transported in different mediums.</p><p><strong>Methods: </strong>A retrospective study of graft detachment rates including 265 surgeries (240 patients) performed between 2019 and 2023. The DSAEK grafts were either surgeon-cut (n = 135) or pre-cut and transported in a dextran-containing medium (n = 82) or in a dextran-free medium (n = 48). All surgeries were performed by a single surgeon (I.G.). The surgeries were categorised according to whether the recipients' eyes had, or did not have, factors associated with an increased risk of graft detachment. Detachment rates were compared for all patients receiving the different kinds of graft, and only for those without risk factors.</p><p><strong>Results: </strong>A significantly higher detachment rate was found among patients receiving pre-cut grafts transported in a dextran-containing medium (32.9%), compared to surgeon-cut grafts (14.1%, p = 0.002), and pre-cut grafts transported in a dextran-free medium (6.3%, p = 0.002) for all recipients (those with and without risk factors for graft detachment). When analysing recipients without risk factors for graft detachment, the detachment rate was still significantly higher with pre-cut tissue transported in a dextran-containing medium (26.9%), compared to surgeon-cut tissue (8.3%, p = 0.002) and pre-cut tissue transported in a dextran-free medium (3.6%, p = 0.01).</p><p><strong>Conclusions: </strong>The use of pre-cut DSAEK tissue transported in a dextran-containing medium significantly increases the risk of graft detachment requiring re-bubbling.</p>","PeriodicalId":6915,"journal":{"name":"Acta Ophthalmologica","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Graft detachment rates in surgeon-cut and pre-cut tissue for DSAEK transported in different mediums.\",\"authors\":\"Thorbjörg Olafsdottir, Faisal Hootak, Carina Forslund, Eydis Olafsdottir, Ingemar Gustafsson\",\"doi\":\"10.1111/aos.16791\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To analyse graft detachment rates after Descemet stripping automated endothelial keratoplasty (DSAEK) using surgeon-cut grafts and pre-cut grafts transported in different mediums.</p><p><strong>Methods: </strong>A retrospective study of graft detachment rates including 265 surgeries (240 patients) performed between 2019 and 2023. The DSAEK grafts were either surgeon-cut (n = 135) or pre-cut and transported in a dextran-containing medium (n = 82) or in a dextran-free medium (n = 48). All surgeries were performed by a single surgeon (I.G.). The surgeries were categorised according to whether the recipients' eyes had, or did not have, factors associated with an increased risk of graft detachment. Detachment rates were compared for all patients receiving the different kinds of graft, and only for those without risk factors.</p><p><strong>Results: </strong>A significantly higher detachment rate was found among patients receiving pre-cut grafts transported in a dextran-containing medium (32.9%), compared to surgeon-cut grafts (14.1%, p = 0.002), and pre-cut grafts transported in a dextran-free medium (6.3%, p = 0.002) for all recipients (those with and without risk factors for graft detachment). When analysing recipients without risk factors for graft detachment, the detachment rate was still significantly higher with pre-cut tissue transported in a dextran-containing medium (26.9%), compared to surgeon-cut tissue (8.3%, p = 0.002) and pre-cut tissue transported in a dextran-free medium (3.6%, p = 0.01).</p><p><strong>Conclusions: </strong>The use of pre-cut DSAEK tissue transported in a dextran-containing medium significantly increases the risk of graft detachment requiring re-bubbling.</p>\",\"PeriodicalId\":6915,\"journal\":{\"name\":\"Acta Ophthalmologica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Ophthalmologica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/aos.16791\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/aos.16791","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:分析使用外科医生切割的移植物和在不同介质中运输的预切割移植物进行 Descemet 剥脱自动内皮角膜成形术(DSAEK)后的移植物脱落率:对2019年至2023年期间进行的265例手术(240名患者)的移植物剥离率进行回顾性研究。DSAEK移植物由外科医生切割(135例)或预先切割并在含葡聚糖的培养基(82例)或不含葡聚糖的培养基(48例)中运输。所有手术均由一名外科医生(I.G.)完成。手术根据受术者的眼睛是否存在与移植物脱落风险增加相关的因素进行分类。比较了所有接受不同类型移植物的患者的脱落率,以及没有风险因素的患者的脱落率:结果:在所有接受移植物的人(有和没有移植物剥离风险因素的人)中,接受在含葡聚糖培养基中运送的预切移植物的病人的剥离率(32.9%)明显高于接受外科医生切割的移植物的病人(14.1%,p = 0.002),接受在不含葡聚糖培养基中运送的预切移植物的病人的剥离率(6.3%,p = 0.002)也明显高于接受外科医生切割的移植物的病人(14.1%,p = 0.002)。在分析无移植物剥离风险因素的受者时,与外科医生切割的组织(8.3%,p = 0.002)和在不含葡聚糖的培养基中运送的预切割组织(3.6%,p = 0.01)相比,在含葡聚糖的培养基中运送的预切割组织的剥离率(26.9%)仍然明显更高:结论:使用含葡聚糖培养基的预切 DSAEK 组织会显著增加移植物脱落的风险,需要重新气泡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Graft detachment rates in surgeon-cut and pre-cut tissue for DSAEK transported in different mediums.

Purpose: To analyse graft detachment rates after Descemet stripping automated endothelial keratoplasty (DSAEK) using surgeon-cut grafts and pre-cut grafts transported in different mediums.

Methods: A retrospective study of graft detachment rates including 265 surgeries (240 patients) performed between 2019 and 2023. The DSAEK grafts were either surgeon-cut (n = 135) or pre-cut and transported in a dextran-containing medium (n = 82) or in a dextran-free medium (n = 48). All surgeries were performed by a single surgeon (I.G.). The surgeries were categorised according to whether the recipients' eyes had, or did not have, factors associated with an increased risk of graft detachment. Detachment rates were compared for all patients receiving the different kinds of graft, and only for those without risk factors.

Results: A significantly higher detachment rate was found among patients receiving pre-cut grafts transported in a dextran-containing medium (32.9%), compared to surgeon-cut grafts (14.1%, p = 0.002), and pre-cut grafts transported in a dextran-free medium (6.3%, p = 0.002) for all recipients (those with and without risk factors for graft detachment). When analysing recipients without risk factors for graft detachment, the detachment rate was still significantly higher with pre-cut tissue transported in a dextran-containing medium (26.9%), compared to surgeon-cut tissue (8.3%, p = 0.002) and pre-cut tissue transported in a dextran-free medium (3.6%, p = 0.01).

Conclusions: The use of pre-cut DSAEK tissue transported in a dextran-containing medium significantly increases the risk of graft detachment requiring re-bubbling.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Ophthalmologica
Acta Ophthalmologica 医学-眼科学
CiteScore
7.60
自引率
5.90%
发文量
433
审稿时长
6 months
期刊介绍: Acta Ophthalmologica is published on behalf of the Acta Ophthalmologica Scandinavica Foundation and is the official scientific publication of the following societies: The Danish Ophthalmological Society, The Finnish Ophthalmological Society, The Icelandic Ophthalmological Society, The Norwegian Ophthalmological Society and The Swedish Ophthalmological Society, and also the European Association for Vision and Eye Research (EVER). Acta Ophthalmologica publishes clinical and experimental original articles, reviews, editorials, educational photo essays (Diagnosis and Therapy in Ophthalmology), case reports and case series, letters to the editor and doctoral theses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信