原位电化学合成用于高性能葡萄糖检测的 Ni/Ni(OH)2/分子印迹聚合物纳米复合材料

IF 8 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Rourke Sylvain , Grace Dykstra , Asky Fungura , Smitha Rao , Yixin Liu
{"title":"原位电化学合成用于高性能葡萄糖检测的 Ni/Ni(OH)2/分子印迹聚合物纳米复合材料","authors":"Rourke Sylvain ,&nbsp;Grace Dykstra ,&nbsp;Asky Fungura ,&nbsp;Smitha Rao ,&nbsp;Yixin Liu","doi":"10.1016/j.snb.2024.136921","DOIUrl":null,"url":null,"abstract":"<div><div>This study presents a novel non-enzymatic glucose sensor that synergistically combines the high catalytic activity of nickel hydroxide (Ni(OH)<sub>2</sub>) with the selective recognition of molecularly imprinted polymers (MIPs). The sensors were fabricated through an entirely in-situ synthesis directly on the electrode, comprising electrodeposition and oxidation of Ni/Ni(OH)<sub>2</sub> nanoparticles and electropolymerization of a glucose-imprinted MIP layer using pyrrole and 3-aminophenyl boronic acid. The integrated MIP layer significantly enhanced selectivity against common interferents while amplifying glucose sensitivity. The resulting sensor demonstrated a high sensitivity of 1802 μA mM<sup>−1</sup> cm<sup>−2</sup> with a linear range from 0.04 to 2.6 mM. Notably, the sensor exhibited remarkable stability, retaining 97.2 % of its original sensitivity after 6 months of room-temperature storage. To extend the linear range, Nafion coatings at two concentrations were applied, achieving ranges up to 0.04–11.6 mM with adjusted sensitivities. This innovative approach, leveraging MIPs to provide selectivity to electrocatalytic nanomaterials, offers a promising strategy for developing high-performance non-enzymatic sensors for glucose and other biomolecules in diabetes monitoring and beyond.</div></div>","PeriodicalId":425,"journal":{"name":"Sensors and Actuators B: Chemical","volume":"424 ","pages":"Article 136921"},"PeriodicalIF":8.0000,"publicationDate":"2024-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In-situ electrochemical synthesis of Ni/Ni(OH)2/molecularly imprinted polymer nanocomposite for high-performance glucose detection\",\"authors\":\"Rourke Sylvain ,&nbsp;Grace Dykstra ,&nbsp;Asky Fungura ,&nbsp;Smitha Rao ,&nbsp;Yixin Liu\",\"doi\":\"10.1016/j.snb.2024.136921\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This study presents a novel non-enzymatic glucose sensor that synergistically combines the high catalytic activity of nickel hydroxide (Ni(OH)<sub>2</sub>) with the selective recognition of molecularly imprinted polymers (MIPs). The sensors were fabricated through an entirely in-situ synthesis directly on the electrode, comprising electrodeposition and oxidation of Ni/Ni(OH)<sub>2</sub> nanoparticles and electropolymerization of a glucose-imprinted MIP layer using pyrrole and 3-aminophenyl boronic acid. The integrated MIP layer significantly enhanced selectivity against common interferents while amplifying glucose sensitivity. The resulting sensor demonstrated a high sensitivity of 1802 μA mM<sup>−1</sup> cm<sup>−2</sup> with a linear range from 0.04 to 2.6 mM. Notably, the sensor exhibited remarkable stability, retaining 97.2 % of its original sensitivity after 6 months of room-temperature storage. To extend the linear range, Nafion coatings at two concentrations were applied, achieving ranges up to 0.04–11.6 mM with adjusted sensitivities. This innovative approach, leveraging MIPs to provide selectivity to electrocatalytic nanomaterials, offers a promising strategy for developing high-performance non-enzymatic sensors for glucose and other biomolecules in diabetes monitoring and beyond.</div></div>\",\"PeriodicalId\":425,\"journal\":{\"name\":\"Sensors and Actuators B: Chemical\",\"volume\":\"424 \",\"pages\":\"Article 136921\"},\"PeriodicalIF\":8.0000,\"publicationDate\":\"2024-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators B: Chemical\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0925400524016514\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators B: Chemical","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0925400524016514","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究提出了一种新型非酶葡萄糖传感器,它协同结合了氢氧化镍(Ni(OH)2)的高催化活性和分子印迹聚合物(MIPs)的选择性识别能力。这种传感器完全是通过直接在电极上进行原位合成制造的,包括 Ni/Ni(OH)2 纳米粒子的电沉积和氧化,以及使用吡咯和 3- 氨基苯硼酸对葡萄糖印迹 MIP 层进行电聚合。集成的 MIP 层大大提高了对常见干扰物的选择性,同时放大了葡萄糖的灵敏度。由此产生的传感器灵敏度高达 1802 μA mM-1 cm-2,线性范围为 0.04 至 2.6 mM。值得注意的是,该传感器表现出极高的稳定性,在室温储存 6 个月后仍能保持 97.2% 的原始灵敏度。为了扩大线性范围,还使用了两种浓度的 Nafion 涂层,从而实现了 0.04 - 11.6 mM 的范围,并调整了灵敏度。这种利用 MIP 为电催化纳米材料提供选择性的创新方法,为开发用于糖尿病监测及其他领域的葡萄糖和其他生物分子的高性能非酶传感器提供了一种前景广阔的策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In-situ electrochemical synthesis of Ni/Ni(OH)2/molecularly imprinted polymer nanocomposite for high-performance glucose detection
This study presents a novel non-enzymatic glucose sensor that synergistically combines the high catalytic activity of nickel hydroxide (Ni(OH)2) with the selective recognition of molecularly imprinted polymers (MIPs). The sensors were fabricated through an entirely in-situ synthesis directly on the electrode, comprising electrodeposition and oxidation of Ni/Ni(OH)2 nanoparticles and electropolymerization of a glucose-imprinted MIP layer using pyrrole and 3-aminophenyl boronic acid. The integrated MIP layer significantly enhanced selectivity against common interferents while amplifying glucose sensitivity. The resulting sensor demonstrated a high sensitivity of 1802 μA mM−1 cm−2 with a linear range from 0.04 to 2.6 mM. Notably, the sensor exhibited remarkable stability, retaining 97.2 % of its original sensitivity after 6 months of room-temperature storage. To extend the linear range, Nafion coatings at two concentrations were applied, achieving ranges up to 0.04–11.6 mM with adjusted sensitivities. This innovative approach, leveraging MIPs to provide selectivity to electrocatalytic nanomaterials, offers a promising strategy for developing high-performance non-enzymatic sensors for glucose and other biomolecules in diabetes monitoring and beyond.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical 工程技术-电化学
CiteScore
14.60
自引率
11.90%
发文量
1776
审稿时长
3.2 months
期刊介绍: Sensors & Actuators, B: Chemical is an international journal focused on the research and development of chemical transducers. It covers chemical sensors and biosensors, chemical actuators, and analytical microsystems. The journal is interdisciplinary, aiming to publish original works showcasing substantial advancements beyond the current state of the art in these fields, with practical applicability to solving meaningful analytical problems. Review articles are accepted by invitation from an Editor of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信