{"title":"利用双极电化学发光技术高度特异性地检测 ROR1 癌症生物标记物","authors":"Seyed Mohammad Reza Mortazavi,&nbsp;Morteza Hosseini,&nbsp;Guobao Xu,&nbsp;Hossein Naderi-Manesh,&nbsp;Mohammad Reza Ganjali","doi":"10.1007/s00604-024-06815-1","DOIUrl":null,"url":null,"abstract":"<div><p>An electrochemiluminescence (ECL) detection system is presented integrated with a bipolar electrode system for sensitive cancer diagnosis. In order to achieve the highest electrical conductivity and redox-active surface area, MXene was chosen as the material for the bipolar electrode. As part of the detection process, the anodic pole of the bipolar electrode was modified with the receptor tyrosine kinase like orphan receptor 1 (ROR1) antibody, followed by an immunoassay using the ROR1 antibody-modified Ag triangle that was identified as significantly enhancing ECL. We measured the ECL of luminol using the anode pole of BPE as an analytical signal in the presence of H<sub>2</sub>O<sub>2</sub>. Additionally, 3D-printed microchannels were used to fabricate the BPE system, to reduce the quantity of sample required. It has been shown that the present immunosensors are low-cost and sensitive in detecting types of cancer, with an extended linear range of 10 fg mL<sup>−1</sup> to 1 µg mL<sup>−1</sup> in the analysis of synthetic samples and achieving an accuracy of ~ 90% in diagnosing ten unknown real samples.</p><h3>Graphical Abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"191 12","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Highly specific detection of ROR1 cancer biomarker with bipolar electrochemiluminescence\",\"authors\":\"Seyed Mohammad Reza Mortazavi,&nbsp;Morteza Hosseini,&nbsp;Guobao Xu,&nbsp;Hossein Naderi-Manesh,&nbsp;Mohammad Reza Ganjali\",\"doi\":\"10.1007/s00604-024-06815-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>An electrochemiluminescence (ECL) detection system is presented integrated with a bipolar electrode system for sensitive cancer diagnosis. In order to achieve the highest electrical conductivity and redox-active surface area, MXene was chosen as the material for the bipolar electrode. As part of the detection process, the anodic pole of the bipolar electrode was modified with the receptor tyrosine kinase like orphan receptor 1 (ROR1) antibody, followed by an immunoassay using the ROR1 antibody-modified Ag triangle that was identified as significantly enhancing ECL. We measured the ECL of luminol using the anode pole of BPE as an analytical signal in the presence of H<sub>2</sub>O<sub>2</sub>. Additionally, 3D-printed microchannels were used to fabricate the BPE system, to reduce the quantity of sample required. It has been shown that the present immunosensors are low-cost and sensitive in detecting types of cancer, with an extended linear range of 10 fg mL<sup>−1</sup> to 1 µg mL<sup>−1</sup> in the analysis of synthetic samples and achieving an accuracy of ~ 90% in diagnosing ten unknown real samples.</p><h3>Graphical Abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":705,\"journal\":{\"name\":\"Microchimica Acta\",\"volume\":\"191 12\",\"pages\":\"\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2024-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microchimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00604-024-06815-1\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-024-06815-1","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种与双极电极系统集成的电化学发光(ECL)检测系统,用于灵敏的癌症诊断。为了获得最高的导电性和氧化还原活性表面积,双极电极选择了 MXene 作为材料。作为检测过程的一部分,双极电极的阳极用受体酪氨酸激酶类孤儿受体 1(ROR1)抗体修饰,然后使用 ROR1 抗体修饰的 Ag 三角形进行免疫测定,结果表明该抗体可显著增强 ECL。在 H2O2 存在的情况下,我们使用 BPE 的阳极作为分析信号测量了发光酚的 ECL。此外,我们还使用 3D 打印微通道来制造 BPE 系统,以减少所需的样品量。研究表明,这种免疫传感器成本低,对癌症类型的检测灵敏度高,在分析合成样品时,线性范围从 10 fg mL-1 扩展到 1 µg mL-1,在诊断十种未知的真实样品时,准确率达到约 90%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Highly specific detection of ROR1 cancer biomarker with bipolar electrochemiluminescence

An electrochemiluminescence (ECL) detection system is presented integrated with a bipolar electrode system for sensitive cancer diagnosis. In order to achieve the highest electrical conductivity and redox-active surface area, MXene was chosen as the material for the bipolar electrode. As part of the detection process, the anodic pole of the bipolar electrode was modified with the receptor tyrosine kinase like orphan receptor 1 (ROR1) antibody, followed by an immunoassay using the ROR1 antibody-modified Ag triangle that was identified as significantly enhancing ECL. We measured the ECL of luminol using the anode pole of BPE as an analytical signal in the presence of H2O2. Additionally, 3D-printed microchannels were used to fabricate the BPE system, to reduce the quantity of sample required. It has been shown that the present immunosensors are low-cost and sensitive in detecting types of cancer, with an extended linear range of 10 fg mL−1 to 1 µg mL−1 in the analysis of synthetic samples and achieving an accuracy of ~ 90% in diagnosing ten unknown real samples.

Graphical Abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信