{"title":"通过不同音爆次数的低强度脉冲超声刺激小鼠 LFP 和 EMG 之间的多尺度耦合。","authors":"Ziqiang Jin, Xiaoling Chen, Zechuan Du, Yi Yuan, Xiaoli Li, Ping Xie","doi":"10.1109/TNSRE.2024.3492158","DOIUrl":null,"url":null,"abstract":"<p><p>Low-intensity pulsed ultrasound stimulation (LIPUS) as a non-invasive, high-spatial resolution and high penetration depth brain modulation technology has been used for modulating neuromuscular function. However, the modulation of neural electrical signal changes in the neuromuscular system by LIPUS remains to be explored. In this study, we stimulated the mouse brain motor cortex by LIPUS with different number of tone burst (NTB) and recorded the local field potential (LFP) signals of the target region and electromyography (EMG) of tail muscle. Multi-Scale Transfer Entropy (MSTE) analysis method was used to explore the multi-scale synchronization characteristics and functional cortico-muscular coupling (FCMC) strength changes of mice LFP-EMG before and after LIPUS under different NTBs. The results show that the MSTE of LFP-EMG before and after LIPUS stimulation was higher than that of EMG-LFP. After adding multi-scale, MSTE has a significant relationship with time scales. When NTB = 200, the scale of extremum is the largest. There was a fitting intersection between LFP-EMG and EMG-LFP scale 7-21 before and after stimulation. After scale averaging, the LFP-EMG after stimulation was lower than that before stimulation, and the EMG-LFP after stimulation was higher than that before stimulation.Conclusion: There is a significant correlation between NTB and time scale before and after LIPUS,as well as upward and downward. Consequently,This study used FCMC methods to study different NTBs and multi-scale relationships, provides new variables from LIPUS parameters and analysis, and provides new reference for clinical applications of LIPUS.</p>","PeriodicalId":13419,"journal":{"name":"IEEE Transactions on Neural Systems and Rehabilitation Engineering","volume":"PP ","pages":""},"PeriodicalIF":4.8000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-scale coupling between LFP and EMG in mice by low- intensity pulsed ultrasound stimulation with different number of tone-burst.\",\"authors\":\"Ziqiang Jin, Xiaoling Chen, Zechuan Du, Yi Yuan, Xiaoli Li, Ping Xie\",\"doi\":\"10.1109/TNSRE.2024.3492158\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Low-intensity pulsed ultrasound stimulation (LIPUS) as a non-invasive, high-spatial resolution and high penetration depth brain modulation technology has been used for modulating neuromuscular function. However, the modulation of neural electrical signal changes in the neuromuscular system by LIPUS remains to be explored. In this study, we stimulated the mouse brain motor cortex by LIPUS with different number of tone burst (NTB) and recorded the local field potential (LFP) signals of the target region and electromyography (EMG) of tail muscle. Multi-Scale Transfer Entropy (MSTE) analysis method was used to explore the multi-scale synchronization characteristics and functional cortico-muscular coupling (FCMC) strength changes of mice LFP-EMG before and after LIPUS under different NTBs. The results show that the MSTE of LFP-EMG before and after LIPUS stimulation was higher than that of EMG-LFP. After adding multi-scale, MSTE has a significant relationship with time scales. When NTB = 200, the scale of extremum is the largest. There was a fitting intersection between LFP-EMG and EMG-LFP scale 7-21 before and after stimulation. After scale averaging, the LFP-EMG after stimulation was lower than that before stimulation, and the EMG-LFP after stimulation was higher than that before stimulation.Conclusion: There is a significant correlation between NTB and time scale before and after LIPUS,as well as upward and downward. Consequently,This study used FCMC methods to study different NTBs and multi-scale relationships, provides new variables from LIPUS parameters and analysis, and provides new reference for clinical applications of LIPUS.</p>\",\"PeriodicalId\":13419,\"journal\":{\"name\":\"IEEE Transactions on Neural Systems and Rehabilitation Engineering\",\"volume\":\"PP \",\"pages\":\"\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Neural Systems and Rehabilitation Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1109/TNSRE.2024.3492158\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Neural Systems and Rehabilitation Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TNSRE.2024.3492158","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

低强度脉冲超声刺激(LIPUS)作为一种无创、高空间分辨率和高穿透深度的脑调制技术,已被用于调节神经肌肉功能。然而,LIPUS 对神经肌肉系统中神经电信号变化的调制仍有待探索。本研究用不同数量的音爆(NTB)刺激小鼠大脑运动皮层,记录靶区局部场电位(LFP)信号和尾肌肌电图(EMG)。采用多尺度传递熵(MSTE)分析方法探讨了不同NTB下LIPUS前后小鼠LFP-EMG的多尺度同步特征和皮质-肌肉功能耦合(FCMC)强度变化。结果表明,LIPUS 刺激前后 LFP-EMG 的 MSTE 均高于 EMG-LFP。加入多尺度后,MSTE 与时间尺度有显著关系。当 NTB = 200 时,极值尺度最大。在刺激前后,LFP-EMG 与 EMG-LFP 第 7-21 刻度之间存在拟合交集。刻度平均后,刺激后的 LFP-EMG 低于刺激前,刺激后的 EMG-LFP 高于刺激前:结论:NTB 与 LIPUS 前后的时间尺度以及向上和向下的时间尺度之间存在明显的相关性。因此,本研究采用FCMC方法研究了不同的NTB和多尺度关系,提供了LIPUS参数和分析的新变量,为LIPUS的临床应用提供了新的参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multi-scale coupling between LFP and EMG in mice by low- intensity pulsed ultrasound stimulation with different number of tone-burst.

Low-intensity pulsed ultrasound stimulation (LIPUS) as a non-invasive, high-spatial resolution and high penetration depth brain modulation technology has been used for modulating neuromuscular function. However, the modulation of neural electrical signal changes in the neuromuscular system by LIPUS remains to be explored. In this study, we stimulated the mouse brain motor cortex by LIPUS with different number of tone burst (NTB) and recorded the local field potential (LFP) signals of the target region and electromyography (EMG) of tail muscle. Multi-Scale Transfer Entropy (MSTE) analysis method was used to explore the multi-scale synchronization characteristics and functional cortico-muscular coupling (FCMC) strength changes of mice LFP-EMG before and after LIPUS under different NTBs. The results show that the MSTE of LFP-EMG before and after LIPUS stimulation was higher than that of EMG-LFP. After adding multi-scale, MSTE has a significant relationship with time scales. When NTB = 200, the scale of extremum is the largest. There was a fitting intersection between LFP-EMG and EMG-LFP scale 7-21 before and after stimulation. After scale averaging, the LFP-EMG after stimulation was lower than that before stimulation, and the EMG-LFP after stimulation was higher than that before stimulation.Conclusion: There is a significant correlation between NTB and time scale before and after LIPUS,as well as upward and downward. Consequently,This study used FCMC methods to study different NTBs and multi-scale relationships, provides new variables from LIPUS parameters and analysis, and provides new reference for clinical applications of LIPUS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.60
自引率
8.20%
发文量
479
审稿时长
6-12 weeks
期刊介绍: Rehabilitative and neural aspects of biomedical engineering, including functional electrical stimulation, acoustic dynamics, human performance measurement and analysis, nerve stimulation, electromyography, motor control and stimulation; and hardware and software applications for rehabilitation engineering and assistive devices.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信