{"title":"监测直接膨胀式空气处理机组中热轮的供热能效比","authors":"Miklos Kassai , Laith Al-Hyari","doi":"10.1016/j.ijrefrig.2024.10.035","DOIUrl":null,"url":null,"abstract":"<div><div>This study presents an on-site examination of the heating energy performance of a real ventilation system, running on the flat roof of a shopping complex building in Hungary. The main focus of this study is to delve into the heating energy efficiency of specific air handling elements, such as the air-to-air rotary heat wheel and the direct expansion heating coil supplied by a variable refrigerant volume outdoor unit under real operation conditions. Additionally, an investigation was carried out during the heating season to scrutinize the potential occurrence of CO<sub>2</sub> transfer from the exhaust airflow to the supply airflow within the heat wheel, which issue highlights a notable limitation of the heat recovery system. Based on the monitored and measured data, the energy saving impact of the heat wheel was 20.5 % on the electric power consumption of the variable refrigerant volume outdoor unit throughout the entire heating period, compared to operation without heat wheel. Furthermore, the relative average of CO<sub>2</sub> cross-contamination is recorded as 3.8 % in the investigated heating season.</div></div>","PeriodicalId":14274,"journal":{"name":"International Journal of Refrigeration-revue Internationale Du Froid","volume":"169 ","pages":"Pages 115-123"},"PeriodicalIF":3.5000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monitoring the heating energy performance of a heat wheel in a direct expansion air handling unit\",\"authors\":\"Miklos Kassai , Laith Al-Hyari\",\"doi\":\"10.1016/j.ijrefrig.2024.10.035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This study presents an on-site examination of the heating energy performance of a real ventilation system, running on the flat roof of a shopping complex building in Hungary. The main focus of this study is to delve into the heating energy efficiency of specific air handling elements, such as the air-to-air rotary heat wheel and the direct expansion heating coil supplied by a variable refrigerant volume outdoor unit under real operation conditions. Additionally, an investigation was carried out during the heating season to scrutinize the potential occurrence of CO<sub>2</sub> transfer from the exhaust airflow to the supply airflow within the heat wheel, which issue highlights a notable limitation of the heat recovery system. Based on the monitored and measured data, the energy saving impact of the heat wheel was 20.5 % on the electric power consumption of the variable refrigerant volume outdoor unit throughout the entire heating period, compared to operation without heat wheel. Furthermore, the relative average of CO<sub>2</sub> cross-contamination is recorded as 3.8 % in the investigated heating season.</div></div>\",\"PeriodicalId\":14274,\"journal\":{\"name\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"volume\":\"169 \",\"pages\":\"Pages 115-123\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S014070072400375X\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Refrigeration-revue Internationale Du Froid","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S014070072400375X","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Monitoring the heating energy performance of a heat wheel in a direct expansion air handling unit
This study presents an on-site examination of the heating energy performance of a real ventilation system, running on the flat roof of a shopping complex building in Hungary. The main focus of this study is to delve into the heating energy efficiency of specific air handling elements, such as the air-to-air rotary heat wheel and the direct expansion heating coil supplied by a variable refrigerant volume outdoor unit under real operation conditions. Additionally, an investigation was carried out during the heating season to scrutinize the potential occurrence of CO2 transfer from the exhaust airflow to the supply airflow within the heat wheel, which issue highlights a notable limitation of the heat recovery system. Based on the monitored and measured data, the energy saving impact of the heat wheel was 20.5 % on the electric power consumption of the variable refrigerant volume outdoor unit throughout the entire heating period, compared to operation without heat wheel. Furthermore, the relative average of CO2 cross-contamination is recorded as 3.8 % in the investigated heating season.
期刊介绍:
The International Journal of Refrigeration is published for the International Institute of Refrigeration (IIR) by Elsevier. It is essential reading for all those wishing to keep abreast of research and industrial news in refrigeration, air conditioning and associated fields. This is particularly important in these times of rapid introduction of alternative refrigerants and the emergence of new technology. The journal has published special issues on alternative refrigerants and novel topics in the field of boiling, condensation, heat pumps, food refrigeration, carbon dioxide, ammonia, hydrocarbons, magnetic refrigeration at room temperature, sorptive cooling, phase change materials and slurries, ejector technology, compressors, and solar cooling.
As well as original research papers the International Journal of Refrigeration also includes review articles, papers presented at IIR conferences, short reports and letters describing preliminary results and experimental details, and letters to the Editor on recent areas of discussion and controversy. Other features include forthcoming events, conference reports and book reviews.
Papers are published in either English or French with the IIR news section in both languages.