{"title":"综合参考区间在诊断老年人亚临床甲状腺功能减退症中的应用:一项回顾性研究。","authors":"Peijuan Li, Wenming Yang, Guohua Tang, Zhipeng Li","doi":"10.7717/peerj.18417","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Thyroid stimulating hormone releasing hormone (TSH) is a key indicator for diagnosing subclinical hypothyroidism (SCH). We evaluated factors affecting TSH levels in elderly SCH, establishing a composite reference interval, and comparing it with traditional one in diagnosis.</p><p><strong>Methods: </strong>We collected data on patients aged ≥60 undergoing physical examinations in Chengdu, screening the influencing factors associated with TSH. Then, a two-dimensional composite reference interval was established for TSH and FT4, and the differences between the new and traditional diagnosing methods were compared.</p><p><strong>Results: </strong>The incidence of subclinical thyroid dysfunction was about 14%, with SCH accounting for 97%. Regression analysis found that TSH levels increase as FT4 and uric acid levels decrease. Compared with the two-dimensional composite reference interval, the traditional one has a higher incidence rate of SCH.</p><p><strong>Conclusion: </strong>Compared with the two-dimensional composite reference interval, the traditional one is more likely to overestimate the incidence rate of SCH, leading to excessive diagnosis and treatment.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11533903/pdf/","citationCount":"0","resultStr":"{\"title\":\"Application of composite reference intervals in the diagnosis of subclinical hypothyroidism in the elderly: a retrospective study.\",\"authors\":\"Peijuan Li, Wenming Yang, Guohua Tang, Zhipeng Li\",\"doi\":\"10.7717/peerj.18417\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Thyroid stimulating hormone releasing hormone (TSH) is a key indicator for diagnosing subclinical hypothyroidism (SCH). We evaluated factors affecting TSH levels in elderly SCH, establishing a composite reference interval, and comparing it with traditional one in diagnosis.</p><p><strong>Methods: </strong>We collected data on patients aged ≥60 undergoing physical examinations in Chengdu, screening the influencing factors associated with TSH. Then, a two-dimensional composite reference interval was established for TSH and FT4, and the differences between the new and traditional diagnosing methods were compared.</p><p><strong>Results: </strong>The incidence of subclinical thyroid dysfunction was about 14%, with SCH accounting for 97%. Regression analysis found that TSH levels increase as FT4 and uric acid levels decrease. Compared with the two-dimensional composite reference interval, the traditional one has a higher incidence rate of SCH.</p><p><strong>Conclusion: </strong>Compared with the two-dimensional composite reference interval, the traditional one is more likely to overestimate the incidence rate of SCH, leading to excessive diagnosis and treatment.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11533903/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.7717/peerj.18417\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.7717/peerj.18417","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Application of composite reference intervals in the diagnosis of subclinical hypothyroidism in the elderly: a retrospective study.
Background: Thyroid stimulating hormone releasing hormone (TSH) is a key indicator for diagnosing subclinical hypothyroidism (SCH). We evaluated factors affecting TSH levels in elderly SCH, establishing a composite reference interval, and comparing it with traditional one in diagnosis.
Methods: We collected data on patients aged ≥60 undergoing physical examinations in Chengdu, screening the influencing factors associated with TSH. Then, a two-dimensional composite reference interval was established for TSH and FT4, and the differences between the new and traditional diagnosing methods were compared.
Results: The incidence of subclinical thyroid dysfunction was about 14%, with SCH accounting for 97%. Regression analysis found that TSH levels increase as FT4 and uric acid levels decrease. Compared with the two-dimensional composite reference interval, the traditional one has a higher incidence rate of SCH.
Conclusion: Compared with the two-dimensional composite reference interval, the traditional one is more likely to overestimate the incidence rate of SCH, leading to excessive diagnosis and treatment.