{"title":"关于科蒂尖器官振动的相位一致性。","authors":"George W.S. Burwood ,&nbsp;Tianying Ren ,&nbsp;Alfred L. Nuttall ,&nbsp;Anders Fridberger","doi":"10.1016/j.heares.2024.109137","DOIUrl":null,"url":null,"abstract":"<div><div>Low-frequency hearing is critically important for speech and music perception. However, technical and anatomical limitations previously made it difficult to study the mechanics of the low-frequency parts of the cochlea, but this changed with the introduction of optical coherence tomography vibrometry. With this technique, sound-evoked vibration can be measured from the apex of a fully intact cochlea. Results of such measurements generated controversy because conventional traveling waves, the hallmark of which is longer group delay closer to the helicotrema, were absent within the apical 20% of the guinea pig cochlea (Burwood <em>et al</em>, Science Advances 8:eabq2773, 2022). The validity of this result was questioned, primarily because group delays were calculated from phase values averaged across many points within the organ of Corti. Here we show that variations in phase across the organ of Corti are minor and does not affect the group delay significantly. We also assess the precision of phase measurements with optical coherence tomography. An artificial target with reflectivity similar to the organ of Corti was used. These measurements revealed that a commonly used commercial optical coherence tomography system produces half-cycle errors in 1-5 % of pixels, leading to a bimodal distribution of phase values. This problem can be easily addressed by using medians when computing averages, as was done by Burwood <em>et al</em> (2022). Hence, neither averaging across pixels nor technical factors can explain the apparent lack of conventional traveling waves at the apex of the guinea pig cochlea at low stimulus levels. The physiological mechanisms that operate at the apex apparently differ from other cochlear regions.</div></div>","PeriodicalId":12881,"journal":{"name":"Hearing Research","volume":"454 ","pages":"Article 109137"},"PeriodicalIF":2.5000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On the phase consistency of apical organ of Corti vibrations\",\"authors\":\"George W.S. Burwood ,&nbsp;Tianying Ren ,&nbsp;Alfred L. Nuttall ,&nbsp;Anders Fridberger\",\"doi\":\"10.1016/j.heares.2024.109137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Low-frequency hearing is critically important for speech and music perception. However, technical and anatomical limitations previously made it difficult to study the mechanics of the low-frequency parts of the cochlea, but this changed with the introduction of optical coherence tomography vibrometry. With this technique, sound-evoked vibration can be measured from the apex of a fully intact cochlea. Results of such measurements generated controversy because conventional traveling waves, the hallmark of which is longer group delay closer to the helicotrema, were absent within the apical 20% of the guinea pig cochlea (Burwood <em>et al</em>, Science Advances 8:eabq2773, 2022). The validity of this result was questioned, primarily because group delays were calculated from phase values averaged across many points within the organ of Corti. Here we show that variations in phase across the organ of Corti are minor and does not affect the group delay significantly. We also assess the precision of phase measurements with optical coherence tomography. An artificial target with reflectivity similar to the organ of Corti was used. These measurements revealed that a commonly used commercial optical coherence tomography system produces half-cycle errors in 1-5 % of pixels, leading to a bimodal distribution of phase values. This problem can be easily addressed by using medians when computing averages, as was done by Burwood <em>et al</em> (2022). Hence, neither averaging across pixels nor technical factors can explain the apparent lack of conventional traveling waves at the apex of the guinea pig cochlea at low stimulus levels. The physiological mechanisms that operate at the apex apparently differ from other cochlear regions.</div></div>\",\"PeriodicalId\":12881,\"journal\":{\"name\":\"Hearing Research\",\"volume\":\"454 \",\"pages\":\"Article 109137\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hearing Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0378595524001904\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hearing Research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378595524001904","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

低频听力对语音和音乐感知至关重要。然而,由于技术和解剖上的限制,以前很难研究耳蜗低频部分的力学结构,但随着光学相干断层扫描振动测量技术的引入,这种情况发生了改变。有了这项技术,就可以从完全完好的耳蜗顶端测量声诱发振动。这种测量的结果引起了争议,因为豚鼠耳蜗顶端 20% 的范围内没有传统的行波,而行波的特点是靠近螺旋体的群延迟较长(Burwood 等人,《科学进展》8:eabq2773,2022 年)。这一结果的有效性受到了质疑,主要是因为群延迟是根据柯蒂器官内许多点的平均相位值计算得出的。在这里,我们证明整个 Corti 器官内的相位变化很小,不会对群体延迟产生重大影响。我们还利用光学相干断层扫描评估了相位测量的精确度。我们使用了一个反射率与柯蒂器官相似的人造目标。这些测量结果表明,常用的商用光学相干断层扫描系统会在 1-5 % 的像素中产生半周期误差,导致相位值呈双峰分布。Burwood 等人(2022 年)在计算平均值时使用了中位数,从而轻松解决了这一问题。因此,无论是跨像素平均还是技术因素,都无法解释豚鼠耳蜗顶点在低刺激水平下明显缺乏常规行波的原因。耳蜗顶端的生理机制显然不同于其他耳蜗区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On the phase consistency of apical organ of Corti vibrations
Low-frequency hearing is critically important for speech and music perception. However, technical and anatomical limitations previously made it difficult to study the mechanics of the low-frequency parts of the cochlea, but this changed with the introduction of optical coherence tomography vibrometry. With this technique, sound-evoked vibration can be measured from the apex of a fully intact cochlea. Results of such measurements generated controversy because conventional traveling waves, the hallmark of which is longer group delay closer to the helicotrema, were absent within the apical 20% of the guinea pig cochlea (Burwood et al, Science Advances 8:eabq2773, 2022). The validity of this result was questioned, primarily because group delays were calculated from phase values averaged across many points within the organ of Corti. Here we show that variations in phase across the organ of Corti are minor and does not affect the group delay significantly. We also assess the precision of phase measurements with optical coherence tomography. An artificial target with reflectivity similar to the organ of Corti was used. These measurements revealed that a commonly used commercial optical coherence tomography system produces half-cycle errors in 1-5 % of pixels, leading to a bimodal distribution of phase values. This problem can be easily addressed by using medians when computing averages, as was done by Burwood et al (2022). Hence, neither averaging across pixels nor technical factors can explain the apparent lack of conventional traveling waves at the apex of the guinea pig cochlea at low stimulus levels. The physiological mechanisms that operate at the apex apparently differ from other cochlear regions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Hearing Research
Hearing Research 医学-耳鼻喉科学
CiteScore
5.30
自引率
14.30%
发文量
163
审稿时长
75 days
期刊介绍: The aim of the journal is to provide a forum for papers concerned with basic peripheral and central auditory mechanisms. Emphasis is on experimental and clinical studies, but theoretical and methodological papers will also be considered. The journal publishes original research papers, review and mini- review articles, rapid communications, method/protocol and perspective articles. Papers submitted should deal with auditory anatomy, physiology, psychophysics, imaging, modeling and behavioural studies in animals and humans, as well as hearing aids and cochlear implants. Papers dealing with the vestibular system are also considered for publication. Papers on comparative aspects of hearing and on effects of drugs and environmental contaminants on hearing function will also be considered. Clinical papers will be accepted when they contribute to the understanding of normal and pathological hearing functions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信