使用掺杂 N 的碳点在 ON-OFF-ON 过程中快速检测 Hg2+。

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Ananya Dutta, Sonit Kumar Gogoi
{"title":"使用掺杂 N 的碳点在 ON-OFF-ON 过程中快速检测 Hg2+。","authors":"Ananya Dutta, Sonit Kumar Gogoi","doi":"10.1039/d4ay01210k","DOIUrl":null,"url":null,"abstract":"<p><p>Contamination of ground water with pollutants released from various anthropogenic activities is a major concern due to its adverse effects on the environment and human health. Rapid and efficient detection of such pollutants is the first step toward remediation of the problem. Herein we report a two-point fluorescence turn OFF-ON detection method for Hg<sup>2+</sup> ions using nitrogen doped carbon dots (NCDs). The NCDs obtained through solvothermal treatment of ammonium citrate tribasic in DMF at 190 °C for four hours exhibited a quantum yield of 9.67%. Hg<sup>2+</sup> detection is demonstrated in two steps, first the quenching of the fluorescence of NCDs by Hg<sup>2+</sup> and second the fluorescence recovery upon addition of ascorbic acid from different sources. A rapid filter paper-based detection device is demonstrated based on the principles developed.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rapid detection of Hg<sup>2+</sup> in an ON-OFF-ON process using N doped carbon dots.\",\"authors\":\"Ananya Dutta, Sonit Kumar Gogoi\",\"doi\":\"10.1039/d4ay01210k\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Contamination of ground water with pollutants released from various anthropogenic activities is a major concern due to its adverse effects on the environment and human health. Rapid and efficient detection of such pollutants is the first step toward remediation of the problem. Herein we report a two-point fluorescence turn OFF-ON detection method for Hg<sup>2+</sup> ions using nitrogen doped carbon dots (NCDs). The NCDs obtained through solvothermal treatment of ammonium citrate tribasic in DMF at 190 °C for four hours exhibited a quantum yield of 9.67%. Hg<sup>2+</sup> detection is demonstrated in two steps, first the quenching of the fluorescence of NCDs by Hg<sup>2+</sup> and second the fluorescence recovery upon addition of ascorbic acid from different sources. A rapid filter paper-based detection device is demonstrated based on the principles developed.</p>\",\"PeriodicalId\":64,\"journal\":{\"name\":\"Analytical Methods\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Methods\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1039/d4ay01210k\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay01210k","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

地下水受到各种人为活动释放的污染物的污染,对环境和人类健康造成了不利影响,是一个令人关注的重大问题。快速有效地检测此类污染物是解决这一问题的第一步。在此,我们报告了一种使用掺氮碳点(NCDs)的 Hg2+ 离子两点荧光关-开检测方法。通过在 190 °C 的 DMF 中对柠檬酸铵三盐进行溶解热处理四小时后得到的 NCD,其量子产率为 9.67%。Hg2+ 检测分为两个步骤:首先是 Hg2+ 对 NCDs 荧光的淬灭,其次是加入不同来源的抗坏血酸后荧光的恢复。根据所开发的原理,演示了一种基于滤纸的快速检测装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rapid detection of Hg2+ in an ON-OFF-ON process using N doped carbon dots.

Contamination of ground water with pollutants released from various anthropogenic activities is a major concern due to its adverse effects on the environment and human health. Rapid and efficient detection of such pollutants is the first step toward remediation of the problem. Herein we report a two-point fluorescence turn OFF-ON detection method for Hg2+ ions using nitrogen doped carbon dots (NCDs). The NCDs obtained through solvothermal treatment of ammonium citrate tribasic in DMF at 190 °C for four hours exhibited a quantum yield of 9.67%. Hg2+ detection is demonstrated in two steps, first the quenching of the fluorescence of NCDs by Hg2+ and second the fluorescence recovery upon addition of ascorbic acid from different sources. A rapid filter paper-based detection device is demonstrated based on the principles developed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信