Cao Tang, Wei Jin, Xue Xiao, Xin Qi, Yanqing Ma, Lei Ma
{"title":"用于室温操作的石墨烯基化学电阻式氢传感器","authors":"Cao Tang, Wei Jin, Xue Xiao, Xin Qi, Yanqing Ma, Lei Ma","doi":"10.1016/j.snb.2024.136889","DOIUrl":null,"url":null,"abstract":"Taking advantage of ultraviolet (UV) irradiation to clean the surface and tuning the charge carriers of graphene, n-doped graphene shows excellent hydrogen sensing capabilities. With assistance of a 265<!-- --> <!-- -->nm UV light irradiation, the response time of sensor reaches 3<!-- --> <!-- -->seconds to 5 ppm hydrogen. And after being relented in ambient condition for a year, it still maintains nearly identical performance. Furthermore, by adding PMMA layer as molecular sieve, the sensor can effectively shield against humidity changes, exhibiting high selectivity towards hydrogen. When the relative humidity varies within the range in 20-70%, the sensor basically maintains similar response performance. This work streamlines the preparation process of hydrogen sensors and introducing exceptional selectivity with the help of a molecular sieve, facilitating the practical application of hydrogen sensors.","PeriodicalId":425,"journal":{"name":"Sensors and Actuators B: Chemical","volume":null,"pages":null},"PeriodicalIF":8.0000,"publicationDate":"2024-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Graphene-based chemiresistive hydrogen sensor for room temperature operation\",\"authors\":\"Cao Tang, Wei Jin, Xue Xiao, Xin Qi, Yanqing Ma, Lei Ma\",\"doi\":\"10.1016/j.snb.2024.136889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Taking advantage of ultraviolet (UV) irradiation to clean the surface and tuning the charge carriers of graphene, n-doped graphene shows excellent hydrogen sensing capabilities. With assistance of a 265<!-- --> <!-- -->nm UV light irradiation, the response time of sensor reaches 3<!-- --> <!-- -->seconds to 5 ppm hydrogen. And after being relented in ambient condition for a year, it still maintains nearly identical performance. Furthermore, by adding PMMA layer as molecular sieve, the sensor can effectively shield against humidity changes, exhibiting high selectivity towards hydrogen. When the relative humidity varies within the range in 20-70%, the sensor basically maintains similar response performance. This work streamlines the preparation process of hydrogen sensors and introducing exceptional selectivity with the help of a molecular sieve, facilitating the practical application of hydrogen sensors.\",\"PeriodicalId\":425,\"journal\":{\"name\":\"Sensors and Actuators B: Chemical\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.0000,\"publicationDate\":\"2024-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators B: Chemical\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.snb.2024.136889\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators B: Chemical","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.snb.2024.136889","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Graphene-based chemiresistive hydrogen sensor for room temperature operation
Taking advantage of ultraviolet (UV) irradiation to clean the surface and tuning the charge carriers of graphene, n-doped graphene shows excellent hydrogen sensing capabilities. With assistance of a 265 nm UV light irradiation, the response time of sensor reaches 3 seconds to 5 ppm hydrogen. And after being relented in ambient condition for a year, it still maintains nearly identical performance. Furthermore, by adding PMMA layer as molecular sieve, the sensor can effectively shield against humidity changes, exhibiting high selectivity towards hydrogen. When the relative humidity varies within the range in 20-70%, the sensor basically maintains similar response performance. This work streamlines the preparation process of hydrogen sensors and introducing exceptional selectivity with the help of a molecular sieve, facilitating the practical application of hydrogen sensors.
期刊介绍:
Sensors & Actuators, B: Chemical is an international journal focused on the research and development of chemical transducers. It covers chemical sensors and biosensors, chemical actuators, and analytical microsystems. The journal is interdisciplinary, aiming to publish original works showcasing substantial advancements beyond the current state of the art in these fields, with practical applicability to solving meaningful analytical problems. Review articles are accepted by invitation from an Editor of the journal.