{"title":"全面分析叶片几何形状对萨沃尼斯水动力涡轮机效率的影响:清洁能源之路","authors":"","doi":"10.1016/j.ecmx.2024.100762","DOIUrl":null,"url":null,"abstract":"<div><div>The rising global demand for clean and renewable energy has intensified interest in hydrokinetic energy harvesting, with Savonius turbines gaining attention due to their simplicity and low cost. While numerous studies have focused on refining blade designs for wind turbines, limited research has been conducted on water turbines to identify the best design. This study investigates the effect of blade geometry on the efficiency of Savonius hydrokinetic turbines to identify the optimal configuration. Three new blade designs were tested, incorporating inner blades and varying blade numbers. These designs were experimentally evaluated to identify the optimal turbine configuration for maximum efficiency, and the findings were then validated through numerical studies. Rotational analysis was conducted to investigate torque variations across a full turbine rotation from 0° to 360°, and flow characteristic analysis was performed by utilizing pressure and contour plots at critical positions, including 0°, minimum torque coefficient (C<sub>T Min</sub>), and maximum torque coefficient (C<sub>T Max</sub>). Results indicate that the 2-blade Savonius turbine achieved the highest efficiency, with a maximum torque coefficient of 0.29 and a power coefficient of 0.22. It demonstrated 63.5 % greater power efficiency compared to the 3-Blade Savonius Turbine, 2.65 times greater than the Segmented Quarter Savonius Turbine, and 2.26 times greater than the Concentric Arc Savonius Turbine. These findings highlight the importance of blade geometry optimization in improving the performance of Savonius turbines for efficient hydrokinetic energy generation.</div></div>","PeriodicalId":37131,"journal":{"name":"Energy Conversion and Management-X","volume":null,"pages":null},"PeriodicalIF":7.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comprehensive analysis of blade geometry effects on Savonius hydrokinetic turbine efficiency: Pathways to clean energy\",\"authors\":\"\",\"doi\":\"10.1016/j.ecmx.2024.100762\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The rising global demand for clean and renewable energy has intensified interest in hydrokinetic energy harvesting, with Savonius turbines gaining attention due to their simplicity and low cost. While numerous studies have focused on refining blade designs for wind turbines, limited research has been conducted on water turbines to identify the best design. This study investigates the effect of blade geometry on the efficiency of Savonius hydrokinetic turbines to identify the optimal configuration. Three new blade designs were tested, incorporating inner blades and varying blade numbers. These designs were experimentally evaluated to identify the optimal turbine configuration for maximum efficiency, and the findings were then validated through numerical studies. Rotational analysis was conducted to investigate torque variations across a full turbine rotation from 0° to 360°, and flow characteristic analysis was performed by utilizing pressure and contour plots at critical positions, including 0°, minimum torque coefficient (C<sub>T Min</sub>), and maximum torque coefficient (C<sub>T Max</sub>). Results indicate that the 2-blade Savonius turbine achieved the highest efficiency, with a maximum torque coefficient of 0.29 and a power coefficient of 0.22. It demonstrated 63.5 % greater power efficiency compared to the 3-Blade Savonius Turbine, 2.65 times greater than the Segmented Quarter Savonius Turbine, and 2.26 times greater than the Concentric Arc Savonius Turbine. These findings highlight the importance of blade geometry optimization in improving the performance of Savonius turbines for efficient hydrokinetic energy generation.</div></div>\",\"PeriodicalId\":37131,\"journal\":{\"name\":\"Energy Conversion and Management-X\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Conversion and Management-X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S259017452400240X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management-X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S259017452400240X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Comprehensive analysis of blade geometry effects on Savonius hydrokinetic turbine efficiency: Pathways to clean energy
The rising global demand for clean and renewable energy has intensified interest in hydrokinetic energy harvesting, with Savonius turbines gaining attention due to their simplicity and low cost. While numerous studies have focused on refining blade designs for wind turbines, limited research has been conducted on water turbines to identify the best design. This study investigates the effect of blade geometry on the efficiency of Savonius hydrokinetic turbines to identify the optimal configuration. Three new blade designs were tested, incorporating inner blades and varying blade numbers. These designs were experimentally evaluated to identify the optimal turbine configuration for maximum efficiency, and the findings were then validated through numerical studies. Rotational analysis was conducted to investigate torque variations across a full turbine rotation from 0° to 360°, and flow characteristic analysis was performed by utilizing pressure and contour plots at critical positions, including 0°, minimum torque coefficient (CT Min), and maximum torque coefficient (CT Max). Results indicate that the 2-blade Savonius turbine achieved the highest efficiency, with a maximum torque coefficient of 0.29 and a power coefficient of 0.22. It demonstrated 63.5 % greater power efficiency compared to the 3-Blade Savonius Turbine, 2.65 times greater than the Segmented Quarter Savonius Turbine, and 2.26 times greater than the Concentric Arc Savonius Turbine. These findings highlight the importance of blade geometry optimization in improving the performance of Savonius turbines for efficient hydrokinetic energy generation.
期刊介绍:
Energy Conversion and Management: X is the open access extension of the reputable journal Energy Conversion and Management, serving as a platform for interdisciplinary research on a wide array of critical energy subjects. The journal is dedicated to publishing original contributions and in-depth technical review articles that present groundbreaking research on topics spanning energy generation, utilization, conversion, storage, transmission, conservation, management, and sustainability.
The scope of Energy Conversion and Management: X encompasses various forms of energy, including mechanical, thermal, nuclear, chemical, electromagnetic, magnetic, and electric energy. It addresses all known energy resources, highlighting both conventional sources like fossil fuels and nuclear power, as well as renewable resources such as solar, biomass, hydro, wind, geothermal, and ocean energy.