上海某综合医院 CT 检查的医学影像频率和剂量分布调查。

IF 1.4 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES
Fanqiaochu Yang, Liangyong Qu, Jie Yao, Zhijun Zhou, Linfeng Gao
{"title":"上海某综合医院 CT 检查的医学影像频率和剂量分布调查。","authors":"Fanqiaochu Yang, Liangyong Qu, Jie Yao, Zhijun Zhou, Linfeng Gao","doi":"10.1088/1361-6498/ad8ce6","DOIUrl":null,"url":null,"abstract":"<p><p>With the continuous advancement and clinical application of CT technology, the increasing collective dose burden from CT scans and associated potential health risks have become significant concerns in radiation protection. Current research increasingly focuses on the cumulative effective dose (CED) resulting from multiple CT scans, often revealing patients with high CEDs, even exceeding 100 mSv. However, reports on CEDs from multiple CT scans in China are scarce. Therefore, we investigated the distribution of CT scan frequencies and CEDs at a comprehensive hospital in Shanghai, examining data from 1 October 2022, to 30 April 2024, sourced from the hospital's radiology information system. The effective dose (<i>E</i>) was estimated using conversion factors<i>k</i>and DLP values from Radiation Dose Structured Reports (RDSR). We assessed the number of CT examinations conducted per patient and evaluated the CED over 1.6 years. During this period, 112 339 CT examinations were performed. Significant differences in CT examination frequencies were observed across different age groups and examination regions (<i>P</i>< 0.01). A total of 78.43% of patients underwent only one CT examination in 1.6 years, while 0.03% had more than 10 examinations, with a maximum of 15. Of the patients, 67.78% (76,142 individuals) received a CED less than 10 mSv, 0.05% (53 patients) received a CED over 50 mSv, and one patient exceeded 100 mSv. In conclusion, this study underscored the necessity of monitoring patients with high CT examination frequencies and CEDs, highlighting the importance of justification and optimization in medical radiation protection.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Survey on the distribution of medical imaging frequencies and dose levels for CT examinations in a comprehensive hospital in Shanghai.\",\"authors\":\"Fanqiaochu Yang, Liangyong Qu, Jie Yao, Zhijun Zhou, Linfeng Gao\",\"doi\":\"10.1088/1361-6498/ad8ce6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>With the continuous advancement and clinical application of CT technology, the increasing collective dose burden from CT scans and associated potential health risks have become significant concerns in radiation protection. Current research increasingly focuses on the cumulative effective dose (CED) resulting from multiple CT scans, often revealing patients with high CEDs, even exceeding 100 mSv. However, reports on CEDs from multiple CT scans in China are scarce. Therefore, we investigated the distribution of CT scan frequencies and CEDs at a comprehensive hospital in Shanghai, examining data from 1 October 2022, to 30 April 2024, sourced from the hospital's radiology information system. The effective dose (<i>E</i>) was estimated using conversion factors<i>k</i>and DLP values from Radiation Dose Structured Reports (RDSR). We assessed the number of CT examinations conducted per patient and evaluated the CED over 1.6 years. During this period, 112 339 CT examinations were performed. Significant differences in CT examination frequencies were observed across different age groups and examination regions (<i>P</i>< 0.01). A total of 78.43% of patients underwent only one CT examination in 1.6 years, while 0.03% had more than 10 examinations, with a maximum of 15. Of the patients, 67.78% (76,142 individuals) received a CED less than 10 mSv, 0.05% (53 patients) received a CED over 50 mSv, and one patient exceeded 100 mSv. In conclusion, this study underscored the necessity of monitoring patients with high CT examination frequencies and CEDs, highlighting the importance of justification and optimization in medical radiation protection.</p>\",\"PeriodicalId\":50068,\"journal\":{\"name\":\"Journal of Radiological Protection\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiological Protection\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1088/1361-6498/ad8ce6\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ad8ce6","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

随着 CT 技术的不断进步和临床应用,CT 扫描产生的集体剂量负担不断增加,相关的潜在健康风险已成为辐射防护领域的重大问题。目前的研究越来越关注多次CT扫描产生的累积有效剂量(CED),经常发现患者的CED很高,甚至超过100 mSv。然而,在中国,关于多次 CT 扫描产生的累积有效剂量(CED)的报道却很少。因此,我们调查了上海一家综合医院的 CT 扫描频率和 CED 分布情况,研究了该医院放射信息系统中 2022 年 10 月 1 日至 2024 年 4 月 30 日的数据。有效剂量(E)是通过辐射剂量结构化报告(RDSR)中的换算系数k和DLP值估算得出的。我们评估了每位患者接受 CT 检查的次数,并对 1.6 年内的 CED 进行了评估。在此期间,共进行了 112,339 次 CT 检查。不同年龄组和检查地区的 CT 检查频率存在显著差异(P < 0.01)。共有 78.43% 的患者在 1.6 年内只接受过一次 CT 检查,而 0.03% 的患者接受过 10 次以上的检查,最多的患者接受过 15 次检查。67.78%的患者(76 142 人)接受的 CED 低于 10 mSv,0.05% 的患者(53 人)接受的 CED 超过 50 mSv,1 名患者超过 100 mSv。总之,这项研究强调了对 CT 检查频率高和 CED 高的患者进行监测的必要性,突出了医疗辐射防护中合理和优化的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Survey on the distribution of medical imaging frequencies and dose levels for CT examinations in a comprehensive hospital in Shanghai.

With the continuous advancement and clinical application of CT technology, the increasing collective dose burden from CT scans and associated potential health risks have become significant concerns in radiation protection. Current research increasingly focuses on the cumulative effective dose (CED) resulting from multiple CT scans, often revealing patients with high CEDs, even exceeding 100 mSv. However, reports on CEDs from multiple CT scans in China are scarce. Therefore, we investigated the distribution of CT scan frequencies and CEDs at a comprehensive hospital in Shanghai, examining data from 1 October 2022, to 30 April 2024, sourced from the hospital's radiology information system. The effective dose (E) was estimated using conversion factorskand DLP values from Radiation Dose Structured Reports (RDSR). We assessed the number of CT examinations conducted per patient and evaluated the CED over 1.6 years. During this period, 112 339 CT examinations were performed. Significant differences in CT examination frequencies were observed across different age groups and examination regions (P< 0.01). A total of 78.43% of patients underwent only one CT examination in 1.6 years, while 0.03% had more than 10 examinations, with a maximum of 15. Of the patients, 67.78% (76,142 individuals) received a CED less than 10 mSv, 0.05% (53 patients) received a CED over 50 mSv, and one patient exceeded 100 mSv. In conclusion, this study underscored the necessity of monitoring patients with high CT examination frequencies and CEDs, highlighting the importance of justification and optimization in medical radiation protection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Radiological Protection
Journal of Radiological Protection 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
2.60
自引率
26.70%
发文量
137
审稿时长
18-36 weeks
期刊介绍: Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments. The journal encourages publication of data and code as well as results.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信