提高阴茎长度测量的精确度:基于证据的拉伸阴茎长度测量技术(SPLINT)综述。

Q3 Medicine
Prabudh Goel, Prativa Choudhury, Komal Kaur Saroya, Vishesh Jain, Anjan Kumar Dhua, Devendra Kumar Yadav, Sachit Anand, Sandeep Agarwala, Kanika Sharma, Vikesh Agrawal, Subhasis Saha, Harpreet Singh, Naveen Sharma, V P Singh
{"title":"提高阴茎长度测量的精确度:基于证据的拉伸阴茎长度测量技术(SPLINT)综述。","authors":"Prabudh Goel, Prativa Choudhury, Komal Kaur Saroya, Vishesh Jain, Anjan Kumar Dhua, Devendra Kumar Yadav, Sachit Anand, Sandeep Agarwala, Kanika Sharma, Vikesh Agrawal, Subhasis Saha, Harpreet Singh, Naveen Sharma, V P Singh","doi":"10.4103/jiaps.jiaps_11_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to synthesize evidence and propose a technique for estimation of stretched penile length (SPL) applicable to children.</p><p><strong>Materials and methods: </strong>This review has been conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. PubMed, Embase, and Scopus databases were queried on penile length (PL) measurement techniques in humans published from 1990 onward. The devices and the techniques used for PL measurement, state of the penis, the habitus of the participants, proximal and distal landmarks for measurement, handling the foreskin and pubic pad of fat, optimal stretching of the penis, and other factors (including the environment) which should be accounted for in the technique were identified from the study cohort (90895 participants across 145 included studies).</p><p><strong>Results: </strong>PL has been represented through flaccid (33.79%), stretched (81.3%), and erect (12.41%) PLs as well as the greatest corporeal length (1.4%). Following devices have been used to measure the PL in the study cohort: rulers [54.68%], calipers [9.7%], measuring tapes [14.5%], coloured measuring strips [2.06%], spatulas/tongue depressors [11.03%], FitKit, syringe [1.4%], cotton swab (and ruler), titan cylinders, slide gauge and ultrasonography [1.37%]. The factors relevant to SPL measurement have been incorporated into the proposed SPL INdicator Technique (SPLINT) which is essentially a holistic extension of the \"<i>Conventional PL Measurement\"</i> technique.</p><p><strong>Conclusions: </strong>There is a wide range of heterogeneity in the technique for estimation of PL across the study cohort; the underlying factors have been identified along with the respective variables, and the SPLINT for SPL has been described.</p>","PeriodicalId":16069,"journal":{"name":"Journal of Indian Association of Pediatric Surgeons","volume":"29 5","pages":"492-504"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11521232/pdf/","citationCount":"0","resultStr":"{\"title\":\"Advancing Precision in Penile Length Measurement: Evidence-based Synthesis of Stretched Penile Length INdicator Technique (SPLINT).\",\"authors\":\"Prabudh Goel, Prativa Choudhury, Komal Kaur Saroya, Vishesh Jain, Anjan Kumar Dhua, Devendra Kumar Yadav, Sachit Anand, Sandeep Agarwala, Kanika Sharma, Vikesh Agrawal, Subhasis Saha, Harpreet Singh, Naveen Sharma, V P Singh\",\"doi\":\"10.4103/jiaps.jiaps_11_24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this study was to synthesize evidence and propose a technique for estimation of stretched penile length (SPL) applicable to children.</p><p><strong>Materials and methods: </strong>This review has been conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. PubMed, Embase, and Scopus databases were queried on penile length (PL) measurement techniques in humans published from 1990 onward. The devices and the techniques used for PL measurement, state of the penis, the habitus of the participants, proximal and distal landmarks for measurement, handling the foreskin and pubic pad of fat, optimal stretching of the penis, and other factors (including the environment) which should be accounted for in the technique were identified from the study cohort (90895 participants across 145 included studies).</p><p><strong>Results: </strong>PL has been represented through flaccid (33.79%), stretched (81.3%), and erect (12.41%) PLs as well as the greatest corporeal length (1.4%). Following devices have been used to measure the PL in the study cohort: rulers [54.68%], calipers [9.7%], measuring tapes [14.5%], coloured measuring strips [2.06%], spatulas/tongue depressors [11.03%], FitKit, syringe [1.4%], cotton swab (and ruler), titan cylinders, slide gauge and ultrasonography [1.37%]. The factors relevant to SPL measurement have been incorporated into the proposed SPL INdicator Technique (SPLINT) which is essentially a holistic extension of the \\\"<i>Conventional PL Measurement\\\"</i> technique.</p><p><strong>Conclusions: </strong>There is a wide range of heterogeneity in the technique for estimation of PL across the study cohort; the underlying factors have been identified along with the respective variables, and the SPLINT for SPL has been described.</p>\",\"PeriodicalId\":16069,\"journal\":{\"name\":\"Journal of Indian Association of Pediatric Surgeons\",\"volume\":\"29 5\",\"pages\":\"492-504\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11521232/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian Association of Pediatric Surgeons\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jiaps.jiaps_11_24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Association of Pediatric Surgeons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jiaps.jiaps_11_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在综合证据,提出一种适用于儿童的阴茎拉伸长度(SPL)估算技术:本综述根据《系统综述和元分析首选报告项目》进行。在 PubMed、Embase 和 Scopus 数据库中查询了 1990 年以来发表的有关人类阴茎长度(PL)测量技术的文章。从研究队列(145 项纳入研究的 90895 名参与者)中确定了用于测量阴茎长度的设备和技术、阴茎状态、参与者的习性、测量的近端和远端地标、包皮和耻骨脂肪垫的处理、阴茎的最佳拉伸以及技术中应考虑的其他因素(包括环境):阴茎松弛长度(33.79%)、拉伸长度(81.3%)和勃起长度(12.41%)以及最大阴茎长度(1.4%)都代表了阴茎长度。研究队列中使用过以下设备测量PL:直尺[54.68%]、卡尺[9.7%]、测量带[14.5%]、彩色测量条[2.06%]、抹刀/压舌板[11.03%]、FitKit、注射器[1.4%]、棉签(和直尺)、钛筒、滑尺和超声波[1.37%]。与声压级测量相关的因素已被纳入拟议的声压级识别技术(SPLINT),该技术本质上是 "传统声压级测量 "技术的整体延伸:结论:在研究队列中,PL 估算技术存在广泛的异质性;已确定了潜在的因素和相应的变量,并描述了 SPL 的 SPLINT。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Advancing Precision in Penile Length Measurement: Evidence-based Synthesis of Stretched Penile Length INdicator Technique (SPLINT).

Purpose: The purpose of this study was to synthesize evidence and propose a technique for estimation of stretched penile length (SPL) applicable to children.

Materials and methods: This review has been conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. PubMed, Embase, and Scopus databases were queried on penile length (PL) measurement techniques in humans published from 1990 onward. The devices and the techniques used for PL measurement, state of the penis, the habitus of the participants, proximal and distal landmarks for measurement, handling the foreskin and pubic pad of fat, optimal stretching of the penis, and other factors (including the environment) which should be accounted for in the technique were identified from the study cohort (90895 participants across 145 included studies).

Results: PL has been represented through flaccid (33.79%), stretched (81.3%), and erect (12.41%) PLs as well as the greatest corporeal length (1.4%). Following devices have been used to measure the PL in the study cohort: rulers [54.68%], calipers [9.7%], measuring tapes [14.5%], coloured measuring strips [2.06%], spatulas/tongue depressors [11.03%], FitKit, syringe [1.4%], cotton swab (and ruler), titan cylinders, slide gauge and ultrasonography [1.37%]. The factors relevant to SPL measurement have been incorporated into the proposed SPL INdicator Technique (SPLINT) which is essentially a holistic extension of the "Conventional PL Measurement" technique.

Conclusions: There is a wide range of heterogeneity in the technique for estimation of PL across the study cohort; the underlying factors have been identified along with the respective variables, and the SPLINT for SPL has been described.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Indian Association of Pediatric Surgeons
Journal of Indian Association of Pediatric Surgeons Medicine-Pediatrics, Perinatology and Child Health
CiteScore
0.80
自引率
0.00%
发文量
148
审稿时长
30 weeks
期刊介绍: Journal of Indian Association of Pediatric Surgeons is the official organ of Indian Association of Pediatric Surgeons. The journal started its journey in October 1995 under the Editor-in-Chief Prof. Subir K Chatterjee. An advisory board was formed with well-versed internationally reputed senior members of our society like Late Prof. R K Gandhi, Prof. I C Pathak, Prof. P Upadhyay, Prof. T Dorairajan and many more. since then the journal is published quarterly uninterrupted. The journal publishes original articles, case reports, review articles and technical innovations. Special issues on different subjects are published every year. There have been several contributions from overseas experts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信