Kaori Kiuchi, Hiroyasu Koizumi, Hideyuki Imai, Takayuki Yoneyama, Lu Sun, Guang Hong
{"title":"钛铸件固定装置的形状再现性。","authors":"Kaori Kiuchi, Hiroyasu Koizumi, Hideyuki Imai, Takayuki Yoneyama, Lu Sun, Guang Hong","doi":"10.4012/dmj.2024-122","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to evaluate the shape reproducibility of retentive devices made of cast titanium. Retention beads were placed on wax patterns for frameworks of composite resin-veneered restoration using four bead adhesives. The wax patterns were invested in the magnesia-based material and titanium was cast using two different casting machines. The percentage of reproduced retentive devices were evaluated using imaging software. Cast specimens were sliced and concavity was evaluated. The contact angle between the wax surface and adhesives was determined with a contact angle meter. The reproducibility of retentive devices was not influenced by the type of adhesive for both machines. Reproducibility, however, was better for castings fabricated by a one-chamber machine with the use of two adhesives. Although the contact angle to wax material of adhesives varied considerably, reproducibility and concavity of retentive devices of titanium castings were guaranteed with the combination of two machines and four bead adhesives.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Shape reproducibility of retentive devices made of cast titanium.\",\"authors\":\"Kaori Kiuchi, Hiroyasu Koizumi, Hideyuki Imai, Takayuki Yoneyama, Lu Sun, Guang Hong\",\"doi\":\"10.4012/dmj.2024-122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to evaluate the shape reproducibility of retentive devices made of cast titanium. Retention beads were placed on wax patterns for frameworks of composite resin-veneered restoration using four bead adhesives. The wax patterns were invested in the magnesia-based material and titanium was cast using two different casting machines. The percentage of reproduced retentive devices were evaluated using imaging software. Cast specimens were sliced and concavity was evaluated. The contact angle between the wax surface and adhesives was determined with a contact angle meter. The reproducibility of retentive devices was not influenced by the type of adhesive for both machines. Reproducibility, however, was better for castings fabricated by a one-chamber machine with the use of two adhesives. Although the contact angle to wax material of adhesives varied considerably, reproducibility and concavity of retentive devices of titanium castings were guaranteed with the combination of two machines and four bead adhesives.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.4012/dmj.2024-122\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.4012/dmj.2024-122","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Shape reproducibility of retentive devices made of cast titanium.
This study aimed to evaluate the shape reproducibility of retentive devices made of cast titanium. Retention beads were placed on wax patterns for frameworks of composite resin-veneered restoration using four bead adhesives. The wax patterns were invested in the magnesia-based material and titanium was cast using two different casting machines. The percentage of reproduced retentive devices were evaluated using imaging software. Cast specimens were sliced and concavity was evaluated. The contact angle between the wax surface and adhesives was determined with a contact angle meter. The reproducibility of retentive devices was not influenced by the type of adhesive for both machines. Reproducibility, however, was better for castings fabricated by a one-chamber machine with the use of two adhesives. Although the contact angle to wax material of adhesives varied considerably, reproducibility and concavity of retentive devices of titanium castings were guaranteed with the combination of two machines and four bead adhesives.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.