利用膜脱溶 Q-ICP-MS 和在线自动分离系统精确测定海水中的超痕量 REEs†

IF 3.1 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Ji-Hao Zhu, Feng-You Chu, Feng Liang, Xian-Ying Luo, Qiang Liu, Quan-Hui Xu, Wei Yu, Yong-Chun Li, Jiang-Gu Lu, Yun-Xiu Li, Yan-Hui Dong, Huai-Ming Li, Jun Zhao and Cai Zhang
{"title":"利用膜脱溶 Q-ICP-MS 和在线自动分离系统精确测定海水中的超痕量 REEs†","authors":"Ji-Hao Zhu, Feng-You Chu, Feng Liang, Xian-Ying Luo, Qiang Liu, Quan-Hui Xu, Wei Yu, Yong-Chun Li, Jiang-Gu Lu, Yun-Xiu Li, Yan-Hui Dong, Huai-Ming Li, Jun Zhao and Cai Zhang","doi":"10.1039/D4JA00240G","DOIUrl":null,"url":null,"abstract":"<p >The determination of rare earth elements (REEs) in seawater, especially marine sediment porewater and open-ocean seawater, is challenging because of their ultra-trace concentrations (ng L<small><sup>−1</sup></small> to pg L<small><sup>−1</sup></small>) and the high salinity of the matrix (approximately 35‰ NaCl), which limits their application in marine science. Herein, we developed an online method for accurate analysis of ultra-trace REEs in seawater using a traditional Q-ICP-MS. The key aspects were: (i) high sensitivity detection in standard mode with no collision/reaction cell functioned, (ii) online automated matrix removal and preconcentration using a commercially available seaFAST system, (iii) use of membrane desolvation to enhance the sensitivity and limit the interferences of LREE oxides on HREEs, and (iv) monitoring and correction of variations in REE signal intensities caused by instrument drift using standard–samples–standard bracketing and an indium internal standard for normalization. The detection limits (0.1–8.0 pg L<small><sup>−1</sup></small>) and procedural blank values (&lt;3 pg L<small><sup>−1</sup></small> except for La, Ce, and Nd) of this method were low enough for accurate determination of REEs in seawater, even for REE concentrations at tens of picograms per liter level. The good accuracy and long-term precision (30 h, average: 3.5%, 1<em>σ</em> RSD, <em>n</em> = 10) were achieved for all the REEs as verified using certified seawater reference standards NASS-7 and CASS-6, and a 10 ng L<small><sup>−1</sup></small> artificial seawater standard, respectively. Each run required only approximately 8 mL of sample and 12 min for the measurement, which are suitable values for practical application. The developed method was used to analyze various natural seawater samples, which demonstrated its effectiveness for exploring subtle changes in REE concentrations, fractionation patterns and anomalies in different marine environments.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 11","pages":" 2870-2883"},"PeriodicalIF":3.1000,"publicationDate":"2024-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accurate determination of ultra-trace REEs in seawater using a membrane desolvation Q-ICP-MS coupled with an online automatic separation system†\",\"authors\":\"Ji-Hao Zhu, Feng-You Chu, Feng Liang, Xian-Ying Luo, Qiang Liu, Quan-Hui Xu, Wei Yu, Yong-Chun Li, Jiang-Gu Lu, Yun-Xiu Li, Yan-Hui Dong, Huai-Ming Li, Jun Zhao and Cai Zhang\",\"doi\":\"10.1039/D4JA00240G\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >The determination of rare earth elements (REEs) in seawater, especially marine sediment porewater and open-ocean seawater, is challenging because of their ultra-trace concentrations (ng L<small><sup>−1</sup></small> to pg L<small><sup>−1</sup></small>) and the high salinity of the matrix (approximately 35‰ NaCl), which limits their application in marine science. Herein, we developed an online method for accurate analysis of ultra-trace REEs in seawater using a traditional Q-ICP-MS. The key aspects were: (i) high sensitivity detection in standard mode with no collision/reaction cell functioned, (ii) online automated matrix removal and preconcentration using a commercially available seaFAST system, (iii) use of membrane desolvation to enhance the sensitivity and limit the interferences of LREE oxides on HREEs, and (iv) monitoring and correction of variations in REE signal intensities caused by instrument drift using standard–samples–standard bracketing and an indium internal standard for normalization. The detection limits (0.1–8.0 pg L<small><sup>−1</sup></small>) and procedural blank values (&lt;3 pg L<small><sup>−1</sup></small> except for La, Ce, and Nd) of this method were low enough for accurate determination of REEs in seawater, even for REE concentrations at tens of picograms per liter level. The good accuracy and long-term precision (30 h, average: 3.5%, 1<em>σ</em> RSD, <em>n</em> = 10) were achieved for all the REEs as verified using certified seawater reference standards NASS-7 and CASS-6, and a 10 ng L<small><sup>−1</sup></small> artificial seawater standard, respectively. Each run required only approximately 8 mL of sample and 12 min for the measurement, which are suitable values for practical application. The developed method was used to analyze various natural seawater samples, which demonstrated its effectiveness for exploring subtle changes in REE concentrations, fractionation patterns and anomalies in different marine environments.</p>\",\"PeriodicalId\":81,\"journal\":{\"name\":\"Journal of Analytical Atomic Spectrometry\",\"volume\":\" 11\",\"pages\":\" 2870-2883\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Atomic Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00240g\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00240g","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

海水,尤其是海洋沉积物孔隙水和公海海水中稀土元素(REEs)的测定极具挑战性,因为稀土元素的超痕量浓度(纳克/升-1 至皮克/升-1)和基质的高盐度(约 35‰ NaCl)限制了其在海洋科学中的应用。在此,我们开发了一种在线方法,利用传统的 Q-ICP-MS 对海水中的超痕量 REEs 进行精确分析。其关键在于(i) 在标准模式下进行高灵敏度检测,不使用碰撞/反应池功能;(ii) 使用市售的 seaFAST 系统进行在线自动基质去除和预浓缩;(iii) 使用膜脱溶来提高灵敏度并限制 LREE 氧化物对 HREEs 的干扰;(iv) 使用标准样品-标准括弧和归一化铟内标来监测和校正仪器漂移引起的 REE 信号强度变化。该方法的检出限(0.1-8.0 pg L-1)和程序空白值(<3 pg L-1,La、Ce 和 Nd 除外)都很低,足以准确测定海水中的 REEs,即使 REEs 浓度达到每升几十皮克的水平。使用经认证的海水标准物质 NASS-7 和 CASS-6 以及 10 ng L-1 人工海水标准物质分别对所有 REEs 进行了验证,结果表明该方法具有良好的准确度和长期精密度(30 h,平均:3.5%,1σ RSD,n = 10)。每次运行仅需约 8 mL 样品和 12 分钟的测量时间,这些值都非常适合实际应用。所开发的方法被用于分析各种天然海水样品,证明了其在探索不同海洋环境中 REE 浓度的微妙变化、分馏模式和异常现象方面的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Accurate determination of ultra-trace REEs in seawater using a membrane desolvation Q-ICP-MS coupled with an online automatic separation system†

Accurate determination of ultra-trace REEs in seawater using a membrane desolvation Q-ICP-MS coupled with an online automatic separation system†

The determination of rare earth elements (REEs) in seawater, especially marine sediment porewater and open-ocean seawater, is challenging because of their ultra-trace concentrations (ng L−1 to pg L−1) and the high salinity of the matrix (approximately 35‰ NaCl), which limits their application in marine science. Herein, we developed an online method for accurate analysis of ultra-trace REEs in seawater using a traditional Q-ICP-MS. The key aspects were: (i) high sensitivity detection in standard mode with no collision/reaction cell functioned, (ii) online automated matrix removal and preconcentration using a commercially available seaFAST system, (iii) use of membrane desolvation to enhance the sensitivity and limit the interferences of LREE oxides on HREEs, and (iv) monitoring and correction of variations in REE signal intensities caused by instrument drift using standard–samples–standard bracketing and an indium internal standard for normalization. The detection limits (0.1–8.0 pg L−1) and procedural blank values (<3 pg L−1 except for La, Ce, and Nd) of this method were low enough for accurate determination of REEs in seawater, even for REE concentrations at tens of picograms per liter level. The good accuracy and long-term precision (30 h, average: 3.5%, 1σ RSD, n = 10) were achieved for all the REEs as verified using certified seawater reference standards NASS-7 and CASS-6, and a 10 ng L−1 artificial seawater standard, respectively. Each run required only approximately 8 mL of sample and 12 min for the measurement, which are suitable values for practical application. The developed method was used to analyze various natural seawater samples, which demonstrated its effectiveness for exploring subtle changes in REE concentrations, fractionation patterns and anomalies in different marine environments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信