罗丹明 B 荧光探针 Y2ST 性能研究

IF 3.2 4区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
Lijun Jin , Lixia Jin , Haiyang Liu , Zhe Wang , yuguang Lv
{"title":"罗丹明 B 荧光探针 Y2ST 性能研究","authors":"Lijun Jin ,&nbsp;Lixia Jin ,&nbsp;Haiyang Liu ,&nbsp;Zhe Wang ,&nbsp;yuguang Lv","doi":"10.1016/j.jics.2024.101420","DOIUrl":null,"url":null,"abstract":"<div><div>Rhodamine B, hydrazine hydrate, and HCl generated the intermediate LBXJ. Next, LBXJ, chromone 3-formaldehyde, and 100 % ethanol prepared the probe Y2ST. NMR, IR, and MS. described the intermediate and probe structures. Following the determination of the structure, tests were conducted on the response time, pH value, linearity, detection limit, accuracy, coordination ratio, and recovery of samples. Additionally, the fluorescence selectivity of ions was compared. The rate of Zn<sup>2+</sup> detection in zinc gluconate was 96.1 % at 5 × 10<sup>−6</sup> mol/L--5 × 10<sup>−5</sup> mol/L, while the detection limit of Y2ST was 0.7 × 10<sup>−6</sup> mol/L. It can be applied to Zn<sup>2+</sup> content determination.</div></div>","PeriodicalId":17276,"journal":{"name":"Journal of the Indian Chemical Society","volume":"101 11","pages":"Article 101420"},"PeriodicalIF":3.2000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on the Properties of rhodamine B fluorescent probe Y2ST\",\"authors\":\"Lijun Jin ,&nbsp;Lixia Jin ,&nbsp;Haiyang Liu ,&nbsp;Zhe Wang ,&nbsp;yuguang Lv\",\"doi\":\"10.1016/j.jics.2024.101420\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Rhodamine B, hydrazine hydrate, and HCl generated the intermediate LBXJ. Next, LBXJ, chromone 3-formaldehyde, and 100 % ethanol prepared the probe Y2ST. NMR, IR, and MS. described the intermediate and probe structures. Following the determination of the structure, tests were conducted on the response time, pH value, linearity, detection limit, accuracy, coordination ratio, and recovery of samples. Additionally, the fluorescence selectivity of ions was compared. The rate of Zn<sup>2+</sup> detection in zinc gluconate was 96.1 % at 5 × 10<sup>−6</sup> mol/L--5 × 10<sup>−5</sup> mol/L, while the detection limit of Y2ST was 0.7 × 10<sup>−6</sup> mol/L. It can be applied to Zn<sup>2+</sup> content determination.</div></div>\",\"PeriodicalId\":17276,\"journal\":{\"name\":\"Journal of the Indian Chemical Society\",\"volume\":\"101 11\",\"pages\":\"Article 101420\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Indian Chemical Society\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0019452224003005\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Indian Chemical Society","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0019452224003005","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

罗丹明 B、水合肼和盐酸生成中间体 LBXJ。接着,LBXJ、3-甲醛铬酮和 100 % 乙醇制备出探针 Y2ST。核磁共振、红外和质谱对中间体和探针的结构进行了描述。确定结构后,对样品的响应时间、pH 值、线性度、检测限、准确度、配位比和回收率进行了测试。此外,还比较了离子的荧光选择性。在 5 × 10-6 mol/L--5 × 10-5 mol/L 的条件下,葡萄糖酸锌中 Zn2+ 的检测率为 96.1%,而 Y2ST 的检测限为 0.7 × 10-6 mol/L。该方法可用于 Zn2+ 含量的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Study on the Properties of rhodamine B fluorescent probe Y2ST

Study on the Properties of rhodamine B fluorescent probe Y2ST
Rhodamine B, hydrazine hydrate, and HCl generated the intermediate LBXJ. Next, LBXJ, chromone 3-formaldehyde, and 100 % ethanol prepared the probe Y2ST. NMR, IR, and MS. described the intermediate and probe structures. Following the determination of the structure, tests were conducted on the response time, pH value, linearity, detection limit, accuracy, coordination ratio, and recovery of samples. Additionally, the fluorescence selectivity of ions was compared. The rate of Zn2+ detection in zinc gluconate was 96.1 % at 5 × 10−6 mol/L--5 × 10−5 mol/L, while the detection limit of Y2ST was 0.7 × 10−6 mol/L. It can be applied to Zn2+ content determination.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
7.70%
发文量
492
审稿时长
3-8 weeks
期刊介绍: The Journal of the Indian Chemical Society publishes original, fundamental, theorical, experimental research work of highest quality in all areas of chemistry, biochemistry, medicinal chemistry, electrochemistry, agrochemistry, chemical engineering and technology, food chemistry, environmental chemistry, etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信