{"title":"利用石英晶体微天平与耗散监测(QCM-D)对红细胞粘弹性进行体外监测的简单灵敏方法","authors":"Simonetta Palleschi ,&nbsp;Leopoldo Silvestroni ,&nbsp;Barbara Rossi ,&nbsp;Simone Dinarelli ,&nbsp;Marco Magi ,&nbsp;Lorenzo Giacomelli ,&nbsp;Andrea Bettucci","doi":"10.1016/j.biosx.2024.100554","DOIUrl":null,"url":null,"abstract":"<div><div>Viscoelasticity (VE) is the intrinsic mechano-dynamic property enabling red blood cells (RBCs) to undergo prompt and repeated deformations while maintaining structural integrity. Assessing RBC VE and how different stressors can affect it is of great interest. Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) is a technology exploiting high-frequency acoustic waves to probe soft matter rheological properties. In the present study, a QCM-D method is reported for <em>in vitro</em> monitoring of cell VE in viable RBCs. The method is based on casting a sensor-adherent cell monolayer and modeling it as an effective viscoelastic medium, and allows to extrapolate proxy values of both the elastic and the viscous cell shear moduli. Real-time VE changes induced by the known cell VE stressors temperature, medium tonicity, glutaraldehyde, methyl-β-cyclodextrin and cytochalasin D have been reliably identified. The method is relatively simple and inexpensive, non-invasive, and able to seize subtle changes of cell biomechanics. Hence, it could be usefully exploited for <em>in vitro</em> assessment of RBC rheological properties and their alterations induced by external chemico-physical stimuli.</div></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"21 ","pages":"Article 100554"},"PeriodicalIF":10.6100,"publicationDate":"2024-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simple and sensitive method for in vitro monitoring of red blood cell viscoelasticity by Quartz Crystal Microbalance with dissipation monitoring (QCM-D)\",\"authors\":\"Simonetta Palleschi ,&nbsp;Leopoldo Silvestroni ,&nbsp;Barbara Rossi ,&nbsp;Simone Dinarelli ,&nbsp;Marco Magi ,&nbsp;Lorenzo Giacomelli ,&nbsp;Andrea Bettucci\",\"doi\":\"10.1016/j.biosx.2024.100554\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Viscoelasticity (VE) is the intrinsic mechano-dynamic property enabling red blood cells (RBCs) to undergo prompt and repeated deformations while maintaining structural integrity. Assessing RBC VE and how different stressors can affect it is of great interest. Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) is a technology exploiting high-frequency acoustic waves to probe soft matter rheological properties. In the present study, a QCM-D method is reported for <em>in vitro</em> monitoring of cell VE in viable RBCs. The method is based on casting a sensor-adherent cell monolayer and modeling it as an effective viscoelastic medium, and allows to extrapolate proxy values of both the elastic and the viscous cell shear moduli. Real-time VE changes induced by the known cell VE stressors temperature, medium tonicity, glutaraldehyde, methyl-β-cyclodextrin and cytochalasin D have been reliably identified. The method is relatively simple and inexpensive, non-invasive, and able to seize subtle changes of cell biomechanics. Hence, it could be usefully exploited for <em>in vitro</em> assessment of RBC rheological properties and their alterations induced by external chemico-physical stimuli.</div></div>\",\"PeriodicalId\":260,\"journal\":{\"name\":\"Biosensors and Bioelectronics: X\",\"volume\":\"21 \",\"pages\":\"Article 100554\"},\"PeriodicalIF\":10.6100,\"publicationDate\":\"2024-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosensors and Bioelectronics: X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590137024001183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590137024001183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

摘要

粘弹性(VE)是红细胞(RBC)在保持结构完整性的同时能够迅速、反复变形的内在机械动力特性。评估 RBC 的 VE 以及不同的应力如何影响它是非常有意义的。具有耗散监测功能的石英晶体微天平(QCM-D)是一种利用高频声波探测软物质流变特性的技术。本研究报告了一种用于体外监测存活 RBC 中细胞 VE 的 QCM-D 方法。该方法基于铸造一个传感器附着细胞单层,并将其建模为有效粘弹性介质,从而推断出细胞弹性和粘性剪切模量的代理值。已知的细胞粘弹性应激源温度、培养基补液度、戊二醛、甲基-β-环糊精和细胞松弛素 D 引起的实时粘弹性变化已被可靠地识别出来。该方法相对简单、廉价、无创,并能捕捉到细胞生物力学的微妙变化。因此,该方法可用于体外评估 RBC 流变特性及其在外部化学物理刺激下的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simple and sensitive method for in vitro monitoring of red blood cell viscoelasticity by Quartz Crystal Microbalance with dissipation monitoring (QCM-D)
Viscoelasticity (VE) is the intrinsic mechano-dynamic property enabling red blood cells (RBCs) to undergo prompt and repeated deformations while maintaining structural integrity. Assessing RBC VE and how different stressors can affect it is of great interest. Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) is a technology exploiting high-frequency acoustic waves to probe soft matter rheological properties. In the present study, a QCM-D method is reported for in vitro monitoring of cell VE in viable RBCs. The method is based on casting a sensor-adherent cell monolayer and modeling it as an effective viscoelastic medium, and allows to extrapolate proxy values of both the elastic and the viscous cell shear moduli. Real-time VE changes induced by the known cell VE stressors temperature, medium tonicity, glutaraldehyde, methyl-β-cyclodextrin and cytochalasin D have been reliably identified. The method is relatively simple and inexpensive, non-invasive, and able to seize subtle changes of cell biomechanics. Hence, it could be usefully exploited for in vitro assessment of RBC rheological properties and their alterations induced by external chemico-physical stimuli.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosensors and Bioelectronics: X
Biosensors and Bioelectronics: X Biochemistry, Genetics and Molecular Biology-Biophysics
CiteScore
4.60
自引率
0.00%
发文量
166
审稿时长
54 days
期刊介绍: Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信