Aniruddh Mohan , Fangwei Cheng , Hongxi Luo , Chris Greig , Eric Larson , Jesse D. Jenkins
{"title":"直接空气捕集与低碳供热的整合:工艺工程和电力系统分析","authors":"Aniruddh Mohan , Fangwei Cheng , Hongxi Luo , Chris Greig , Eric Larson , Jesse D. Jenkins","doi":"10.1016/j.enconman.2024.119136","DOIUrl":null,"url":null,"abstract":"<div><div>Direct air capture (DAC) of carbon dioxide (CO<sub>2</sub>) is energy intensive given the low concentration (<span><math><mo><</mo></math></span>0.1%) of CO<sub>2</sub> in ambient air, but offers relatively strong verification of removals and limited land constraints to scale. Lower temperature solid sorbent based DAC could be coupled on-site with low carbon thermal generators such as nuclear power plants. Here, we undertake a unique interdisciplinary study combining process engineering with a detailed macro-energy system optimization model to evaluate the system-level impacts of such plant designs in the Texas electricity system. We contrast this with using grid power to operate a heat pump to regenerate the sorbent. Our analysis identifies net carbon removal costs accounting for power system impacts and resulting indirect CO<span><math><msub><mrow></mrow><mrow><mn>2</mn></mrow></msub></math></span> emissions from DAC energy consumption. We find that inefficient configurations of DAC at a nuclear power plant can lead to increases in power sector emissions relative to a case without DAC, at a scale that would cancel out almost 50% of the carbon removal from DAC. Net removal costs for the most efficient configurations increase by roughly 18% once indirect power system-level impacts are considered, though this is comparable to the indirect systems-level emissions from operating grid-powered heat pumps for sorbent regeneration. Our study therefore highlights the need for DAC energy procurement to be guided by consideration of indirect emission impacts on the electricity system. Finally, DAC could potentially create demand pull for zero carbon firm generation, accelerating decarbonization relative to a world without such DAC deployment. We find that DAC operators would have to be willing to pay existing or new nuclear power plants roughly $30–80/tCO<sub>2</sub> or $150–400/tCO<sub>2</sub> respectively, for input energy, to enable nuclear plants to be economically competitive in least cost electricity markets that do not have carbon constraints or subsidies for nuclear energy.</div></div>","PeriodicalId":11664,"journal":{"name":"Energy Conversion and Management","volume":"322 ","pages":"Article 119136"},"PeriodicalIF":9.9000,"publicationDate":"2024-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Direct air capture integration with low-carbon heat: Process engineering and power system analysis\",\"authors\":\"Aniruddh Mohan , Fangwei Cheng , Hongxi Luo , Chris Greig , Eric Larson , Jesse D. Jenkins\",\"doi\":\"10.1016/j.enconman.2024.119136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Direct air capture (DAC) of carbon dioxide (CO<sub>2</sub>) is energy intensive given the low concentration (<span><math><mo><</mo></math></span>0.1%) of CO<sub>2</sub> in ambient air, but offers relatively strong verification of removals and limited land constraints to scale. Lower temperature solid sorbent based DAC could be coupled on-site with low carbon thermal generators such as nuclear power plants. Here, we undertake a unique interdisciplinary study combining process engineering with a detailed macro-energy system optimization model to evaluate the system-level impacts of such plant designs in the Texas electricity system. We contrast this with using grid power to operate a heat pump to regenerate the sorbent. Our analysis identifies net carbon removal costs accounting for power system impacts and resulting indirect CO<span><math><msub><mrow></mrow><mrow><mn>2</mn></mrow></msub></math></span> emissions from DAC energy consumption. We find that inefficient configurations of DAC at a nuclear power plant can lead to increases in power sector emissions relative to a case without DAC, at a scale that would cancel out almost 50% of the carbon removal from DAC. Net removal costs for the most efficient configurations increase by roughly 18% once indirect power system-level impacts are considered, though this is comparable to the indirect systems-level emissions from operating grid-powered heat pumps for sorbent regeneration. Our study therefore highlights the need for DAC energy procurement to be guided by consideration of indirect emission impacts on the electricity system. Finally, DAC could potentially create demand pull for zero carbon firm generation, accelerating decarbonization relative to a world without such DAC deployment. We find that DAC operators would have to be willing to pay existing or new nuclear power plants roughly $30–80/tCO<sub>2</sub> or $150–400/tCO<sub>2</sub> respectively, for input energy, to enable nuclear plants to be economically competitive in least cost electricity markets that do not have carbon constraints or subsidies for nuclear energy.</div></div>\",\"PeriodicalId\":11664,\"journal\":{\"name\":\"Energy Conversion and Management\",\"volume\":\"322 \",\"pages\":\"Article 119136\"},\"PeriodicalIF\":9.9000,\"publicationDate\":\"2024-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Conversion and Management\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S019689042401077X\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S019689042401077X","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Direct air capture integration with low-carbon heat: Process engineering and power system analysis
Direct air capture (DAC) of carbon dioxide (CO2) is energy intensive given the low concentration (0.1%) of CO2 in ambient air, but offers relatively strong verification of removals and limited land constraints to scale. Lower temperature solid sorbent based DAC could be coupled on-site with low carbon thermal generators such as nuclear power plants. Here, we undertake a unique interdisciplinary study combining process engineering with a detailed macro-energy system optimization model to evaluate the system-level impacts of such plant designs in the Texas electricity system. We contrast this with using grid power to operate a heat pump to regenerate the sorbent. Our analysis identifies net carbon removal costs accounting for power system impacts and resulting indirect CO emissions from DAC energy consumption. We find that inefficient configurations of DAC at a nuclear power plant can lead to increases in power sector emissions relative to a case without DAC, at a scale that would cancel out almost 50% of the carbon removal from DAC. Net removal costs for the most efficient configurations increase by roughly 18% once indirect power system-level impacts are considered, though this is comparable to the indirect systems-level emissions from operating grid-powered heat pumps for sorbent regeneration. Our study therefore highlights the need for DAC energy procurement to be guided by consideration of indirect emission impacts on the electricity system. Finally, DAC could potentially create demand pull for zero carbon firm generation, accelerating decarbonization relative to a world without such DAC deployment. We find that DAC operators would have to be willing to pay existing or new nuclear power plants roughly $30–80/tCO2 or $150–400/tCO2 respectively, for input energy, to enable nuclear plants to be economically competitive in least cost electricity markets that do not have carbon constraints or subsidies for nuclear energy.
期刊介绍:
The journal Energy Conversion and Management provides a forum for publishing original contributions and comprehensive technical review articles of interdisciplinary and original research on all important energy topics.
The topics considered include energy generation, utilization, conversion, storage, transmission, conservation, management and sustainability. These topics typically involve various types of energy such as mechanical, thermal, nuclear, chemical, electromagnetic, magnetic and electric. These energy types cover all known energy resources, including renewable resources (e.g., solar, bio, hydro, wind, geothermal and ocean energy), fossil fuels and nuclear resources.