{"title":"基于下颌运动记录的全数字化工作流程的固定假体康复。病例系列。","authors":"Mauro Merli, Luca Aquilanti, Umberto Pagliaro, Giorgia Mariotti, Marco Merli, Michele Nieri, Giorgio Rappelli","doi":"10.11607/ijp.2024","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The study aims at evaluating the impact of a full digital workflow on the restoration of masticatory function and aesthetic features in subjects rehabilitated with fixed prosthesis.</p><p><strong>Materials and methods: </strong>The study involved 12 adult participants in need of complex rehabilitation due to masticatory dysfunction. They underwent a comprehensive diagnostic examination involving intraoral scan, facial 3D-photos, jaw kinematics recording, and Cone Beam Computed Tomography extended to temporo-mandibular joint. The subjects were consecutively treated with fixed prosthesis following surgical and implant therapy using a full-digital individualized workflow. Three different study moments were set: diagnostic phase (T0), one week after the delivery of the prototype (T1) and one week after the delivery of the final prosthetic solution (T2).</p><p><strong>Results: </strong>Jaw kinematics recording showed a widening of movements at T2 compared to T0. Sagittal movements increased by 5.7±6.4 mm (95%CI from 1.7 to 9.8, P = 0.010), frontal movements increased by 7.2±5.6 mm (95%CI from 3.6 to 10.8, P = 0.001), and horizontal movements increased by 1.7±4.5 mm (95%CI from -1.1 to 4.6, P = 0.210). Occlusal adjustment timing at T1 was 350±175 seconds, while at T2 was 677±286. At T2 functional VAS was 9.4±0.4 while aesthetic VAS was 9.3±0.4.</p><p><strong>Conclusions: </strong>The rehabilitation process using the full digital workflow showed a widening of the sagittal and frontal masticatory movements with short occlusal adjustment time and with functional and aesthetic satisfaction by all the subjects.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fixed Prosthetic Rehabilitation with Full Digital Workflow Based on Jaw Kinematics Recording. A Case Series.\",\"authors\":\"Mauro Merli, Luca Aquilanti, Umberto Pagliaro, Giorgia Mariotti, Marco Merli, Michele Nieri, Giorgio Rappelli\",\"doi\":\"10.11607/ijp.2024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The study aims at evaluating the impact of a full digital workflow on the restoration of masticatory function and aesthetic features in subjects rehabilitated with fixed prosthesis.</p><p><strong>Materials and methods: </strong>The study involved 12 adult participants in need of complex rehabilitation due to masticatory dysfunction. They underwent a comprehensive diagnostic examination involving intraoral scan, facial 3D-photos, jaw kinematics recording, and Cone Beam Computed Tomography extended to temporo-mandibular joint. The subjects were consecutively treated with fixed prosthesis following surgical and implant therapy using a full-digital individualized workflow. Three different study moments were set: diagnostic phase (T0), one week after the delivery of the prototype (T1) and one week after the delivery of the final prosthetic solution (T2).</p><p><strong>Results: </strong>Jaw kinematics recording showed a widening of movements at T2 compared to T0. Sagittal movements increased by 5.7±6.4 mm (95%CI from 1.7 to 9.8, P = 0.010), frontal movements increased by 7.2±5.6 mm (95%CI from 3.6 to 10.8, P = 0.001), and horizontal movements increased by 1.7±4.5 mm (95%CI from -1.1 to 4.6, P = 0.210). Occlusal adjustment timing at T1 was 350±175 seconds, while at T2 was 677±286. At T2 functional VAS was 9.4±0.4 while aesthetic VAS was 9.3±0.4.</p><p><strong>Conclusions: </strong>The rehabilitation process using the full digital workflow showed a widening of the sagittal and frontal masticatory movements with short occlusal adjustment time and with functional and aesthetic satisfaction by all the subjects.</p>\",\"PeriodicalId\":94232,\"journal\":{\"name\":\"The International journal of prosthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International journal of prosthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.2024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.2024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fixed Prosthetic Rehabilitation with Full Digital Workflow Based on Jaw Kinematics Recording. A Case Series.
Purpose: The study aims at evaluating the impact of a full digital workflow on the restoration of masticatory function and aesthetic features in subjects rehabilitated with fixed prosthesis.
Materials and methods: The study involved 12 adult participants in need of complex rehabilitation due to masticatory dysfunction. They underwent a comprehensive diagnostic examination involving intraoral scan, facial 3D-photos, jaw kinematics recording, and Cone Beam Computed Tomography extended to temporo-mandibular joint. The subjects were consecutively treated with fixed prosthesis following surgical and implant therapy using a full-digital individualized workflow. Three different study moments were set: diagnostic phase (T0), one week after the delivery of the prototype (T1) and one week after the delivery of the final prosthetic solution (T2).
Results: Jaw kinematics recording showed a widening of movements at T2 compared to T0. Sagittal movements increased by 5.7±6.4 mm (95%CI from 1.7 to 9.8, P = 0.010), frontal movements increased by 7.2±5.6 mm (95%CI from 3.6 to 10.8, P = 0.001), and horizontal movements increased by 1.7±4.5 mm (95%CI from -1.1 to 4.6, P = 0.210). Occlusal adjustment timing at T1 was 350±175 seconds, while at T2 was 677±286. At T2 functional VAS was 9.4±0.4 while aesthetic VAS was 9.3±0.4.
Conclusions: The rehabilitation process using the full digital workflow showed a widening of the sagittal and frontal masticatory movements with short occlusal adjustment time and with functional and aesthetic satisfaction by all the subjects.