Cara Brainerd, Maya A Singh, John Tatka, Cosette Craig, Shane Gilligan-Steinberg, Nuttada Panpradist, Megan M Chang, Barry Lutz, Ayokunle O Olanrewaju
{"title":"逆转录酶活性(REACT)测定法,用于对用于艾滋病治疗和预防的成熟和新兴抗逆转录病毒药物进行床旁测量。","authors":"Cara Brainerd, Maya A Singh, John Tatka, Cosette Craig, Shane Gilligan-Steinberg, Nuttada Panpradist, Megan M Chang, Barry Lutz, Ayokunle O Olanrewaju","doi":"10.1007/s00216-024-05602-4","DOIUrl":null,"url":null,"abstract":"<p><p>Maintaining adequate levels of antiretroviral (ARV) medications is crucial for the efficacy of HIV treatment and prevention regimens. Monitoring ARV levels can predict or prevent adverse health outcomes like treatment failure or drug resistance. However, conventional ARV measurement using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is slow, expensive, and centralized delaying clinical and behavioral interventions. We previously developed a rapid enzymatic assay for measuring nucleotide reverse transcriptase inhibitors (NRTIs) - the backbone of HIV treatment and prevention regimens - based on the drugs' termination of DNA synthesis by HIV reverse transcriptase (RT) enzyme. Here, we expand our work to include non-nucleoside reverse transcriptase inhibitors (NNRTIs) - an ARV class used in established and emerging HIV treatment and prevention regimens. We demonstrate that the REverse Transcriptase ACTivity (REACT) assay can detect NNRTIs including medications used in oral and long-acting/extended-release HIV treatment and prevention. We demonstrate that REACT can measure NNRTIs spiked in either buffer or diluted plasma and that fluorescence can be measured on both a traditional plate reader and an inexpensive portable reader that can be deployed in point-of-care (POC) settings. REACT measured clinically relevant concentrations of five NNRTIs spiked in aqueous buffer. REACT measurements showed excellent agreement between the plate reader and the portable reader, with a high correlation in both aqueous buffer (Pearson's r = 0.9807, P < 0.0001) and diluted plasma (Pearson's r = 0.9681, P < 0.0001). REACT has the potential to provide rapid measurement of NNRTIs in POC settings and may help to improve HIV treatment and prevention outcomes.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"REverse transcriptase ACTivity (REACT) assay for point-of-care measurement of established and emerging antiretrovirals for HIV treatment and prevention.\",\"authors\":\"Cara Brainerd, Maya A Singh, John Tatka, Cosette Craig, Shane Gilligan-Steinberg, Nuttada Panpradist, Megan M Chang, Barry Lutz, Ayokunle O Olanrewaju\",\"doi\":\"10.1007/s00216-024-05602-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Maintaining adequate levels of antiretroviral (ARV) medications is crucial for the efficacy of HIV treatment and prevention regimens. Monitoring ARV levels can predict or prevent adverse health outcomes like treatment failure or drug resistance. However, conventional ARV measurement using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is slow, expensive, and centralized delaying clinical and behavioral interventions. We previously developed a rapid enzymatic assay for measuring nucleotide reverse transcriptase inhibitors (NRTIs) - the backbone of HIV treatment and prevention regimens - based on the drugs' termination of DNA synthesis by HIV reverse transcriptase (RT) enzyme. Here, we expand our work to include non-nucleoside reverse transcriptase inhibitors (NNRTIs) - an ARV class used in established and emerging HIV treatment and prevention regimens. We demonstrate that the REverse Transcriptase ACTivity (REACT) assay can detect NNRTIs including medications used in oral and long-acting/extended-release HIV treatment and prevention. We demonstrate that REACT can measure NNRTIs spiked in either buffer or diluted plasma and that fluorescence can be measured on both a traditional plate reader and an inexpensive portable reader that can be deployed in point-of-care (POC) settings. REACT measured clinically relevant concentrations of five NNRTIs spiked in aqueous buffer. REACT measurements showed excellent agreement between the plate reader and the portable reader, with a high correlation in both aqueous buffer (Pearson's r = 0.9807, P < 0.0001) and diluted plasma (Pearson's r = 0.9681, P < 0.0001). REACT has the potential to provide rapid measurement of NNRTIs in POC settings and may help to improve HIV treatment and prevention outcomes.</p>\",\"PeriodicalId\":462,\"journal\":{\"name\":\"Analytical and Bioanalytical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical and Bioanalytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1007/s00216-024-05602-4\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-024-05602-4","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
摘要
保持足够水平的抗逆转录病毒(ARV)药物对艾滋病治疗和预防方案的疗效至关重要。监测抗逆转录病毒药物水平可以预测或预防治疗失败或耐药性等不良健康结果。然而,使用液相色谱-串联质谱法(LC-MS/MS)进行传统的抗逆转录病毒药物测量既缓慢又昂贵,而且需要集中进行,延误了临床和行为干预。我们之前开发了一种快速酶学检测方法,用于检测核苷酸逆转录酶抑制剂(NRTIs)--HIV 治疗和预防方案的支柱--基于药物终止 HIV 逆转录酶(RT)的 DNA 合成。在这里,我们将工作范围扩大到非核苷类逆转录酶抑制剂(NNRTIs)--一种用于既有和新兴艾滋病治疗和预防方案的抗逆转录病毒类药物。我们证明了逆转录酶活性(REACT)测定可以检测 NNRTIs,包括用于口服和长效/缓释 HIV 治疗和预防的药物。我们证明 REACT 可以检测缓冲液或稀释血浆中添加的 NNRTIs,而且荧光可以在传统的平板阅读器和廉价的便携式阅读器上进行测量,便携式阅读器可用于护理点 (POC) 环境。REACT 可测量水性缓冲液中添加的五种 NNRTI 的临床相关浓度。REACT 的测量结果表明,平板阅读器和便携式阅读器之间的一致性非常好,在水缓冲液中的相关性很高(Pearson's r = 0.9807,P<0.05)。
REverse transcriptase ACTivity (REACT) assay for point-of-care measurement of established and emerging antiretrovirals for HIV treatment and prevention.
Maintaining adequate levels of antiretroviral (ARV) medications is crucial for the efficacy of HIV treatment and prevention regimens. Monitoring ARV levels can predict or prevent adverse health outcomes like treatment failure or drug resistance. However, conventional ARV measurement using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is slow, expensive, and centralized delaying clinical and behavioral interventions. We previously developed a rapid enzymatic assay for measuring nucleotide reverse transcriptase inhibitors (NRTIs) - the backbone of HIV treatment and prevention regimens - based on the drugs' termination of DNA synthesis by HIV reverse transcriptase (RT) enzyme. Here, we expand our work to include non-nucleoside reverse transcriptase inhibitors (NNRTIs) - an ARV class used in established and emerging HIV treatment and prevention regimens. We demonstrate that the REverse Transcriptase ACTivity (REACT) assay can detect NNRTIs including medications used in oral and long-acting/extended-release HIV treatment and prevention. We demonstrate that REACT can measure NNRTIs spiked in either buffer or diluted plasma and that fluorescence can be measured on both a traditional plate reader and an inexpensive portable reader that can be deployed in point-of-care (POC) settings. REACT measured clinically relevant concentrations of five NNRTIs spiked in aqueous buffer. REACT measurements showed excellent agreement between the plate reader and the portable reader, with a high correlation in both aqueous buffer (Pearson's r = 0.9807, P < 0.0001) and diluted plasma (Pearson's r = 0.9681, P < 0.0001). REACT has the potential to provide rapid measurement of NNRTIs in POC settings and may help to improve HIV treatment and prevention outcomes.
期刊介绍:
Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.