{"title":"磁性分子印迹吸附剂在线预富集双酚 A 及其在天然介质中的测定","authors":"A. S. Gubin,&nbsp;A. A. Kushnir,&nbsp;P. T. Sukhanov","doi":"10.1134/S1061934824700850","DOIUrl":null,"url":null,"abstract":"<p>An original bench-scale installation based on the principles of online magnetic solid-phase extraction is developed. The setup includes a borosilicate glass column packed with Fe<sub>3</sub>O<sub>4</sub>@MIP-BPA, which is fixed with two neodymium magnets. Compared to using one magnet, a design with two magnets ensures the uniform distribution of the sorbent over the entire cross-section of the column. The highest concentration factors (<i>EF</i> = 3216) and the degree of desorption of bisphenol A (<b>BPA</b>) are achieved, respectively, at a volumetric solution flow rate (<i>W</i>) of 2.0 mL/min and with eluting BPA with methanol (<i>W</i> = 0.4 mL/min). The determination of BPA in concentrates from model media by GC−MS provides high sensitivity of the developed method for determining BPA. In analyzing model solutions prepared in distilled water, the limit of detection (<b>LOD</b>) is 0.3 ng/L. In analyzing river water, the LOD increases by approximately 2 times. In analyzing soils, LOD = 2.2 ng/kg dry weight. Soils, compared to water bodies, contain a larger number of interfering components; the sensitivity of the method is reduced by 7–8 times. Bottom sediments are even more contaminated; the LOD more than doubles compared to the determination of BPA in soils.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Online Preconcentration of Bisphenol A on a Magnetic Molecularly Imprinted Sorbent and its Determination in Natural Media\",\"authors\":\"A. S. Gubin,&nbsp;A. A. Kushnir,&nbsp;P. T. Sukhanov\",\"doi\":\"10.1134/S1061934824700850\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>An original bench-scale installation based on the principles of online magnetic solid-phase extraction is developed. The setup includes a borosilicate glass column packed with Fe<sub>3</sub>O<sub>4</sub>@MIP-BPA, which is fixed with two neodymium magnets. Compared to using one magnet, a design with two magnets ensures the uniform distribution of the sorbent over the entire cross-section of the column. The highest concentration factors (<i>EF</i> = 3216) and the degree of desorption of bisphenol A (<b>BPA</b>) are achieved, respectively, at a volumetric solution flow rate (<i>W</i>) of 2.0 mL/min and with eluting BPA with methanol (<i>W</i> = 0.4 mL/min). The determination of BPA in concentrates from model media by GC−MS provides high sensitivity of the developed method for determining BPA. In analyzing model solutions prepared in distilled water, the limit of detection (<b>LOD</b>) is 0.3 ng/L. In analyzing river water, the LOD increases by approximately 2 times. In analyzing soils, LOD = 2.2 ng/kg dry weight. Soils, compared to water bodies, contain a larger number of interfering components; the sensitivity of the method is reduced by 7–8 times. Bottom sediments are even more contaminated; the LOD more than doubles compared to the determination of BPA in soils.</p>\",\"PeriodicalId\":606,\"journal\":{\"name\":\"Journal of Analytical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-10-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1061934824700850\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1134/S1061934824700850","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

根据在线磁性固相萃取的原理,开发了一种独创的台式装置。该装置包括一个装有 Fe3O4@MIP-BPA 的硼硅玻璃柱,柱子用两块钕磁铁固定。与使用一块磁铁相比,使用两块磁铁的设计可确保吸附剂在整个色谱柱横截面上的均匀分布。在体积溶液流速(W)为 2.0 mL/min 和用甲醇洗脱双酚 A 时(W = 0.4 mL/min),双酚 A 的浓度系数(EF = 3216)和解吸程度分别达到最高。利用气相色谱-质谱法测定模型介质浓缩物中的双酚 A,为所开发的双酚 A 测定方法提供了高灵敏度。在分析蒸馏水制备的模型溶液时,检测限(LOD)为 0.3 ng/L。在分析河水时,检测限提高了约 2 倍。在分析土壤时,检测限 = 2.2 纳克/千克干重。与水体相比,土壤中含有更多的干扰成分;该方法的灵敏度降低了 7-8 倍。底层沉积物的污染程度更高;与测定土壤中的双酚 A 相比,检测限增加了一倍多。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Online Preconcentration of Bisphenol A on a Magnetic Molecularly Imprinted Sorbent and its Determination in Natural Media

Online Preconcentration of Bisphenol A on a Magnetic Molecularly Imprinted Sorbent and its Determination in Natural Media

An original bench-scale installation based on the principles of online magnetic solid-phase extraction is developed. The setup includes a borosilicate glass column packed with Fe3O4@MIP-BPA, which is fixed with two neodymium magnets. Compared to using one magnet, a design with two magnets ensures the uniform distribution of the sorbent over the entire cross-section of the column. The highest concentration factors (EF = 3216) and the degree of desorption of bisphenol A (BPA) are achieved, respectively, at a volumetric solution flow rate (W) of 2.0 mL/min and with eluting BPA with methanol (W = 0.4 mL/min). The determination of BPA in concentrates from model media by GC−MS provides high sensitivity of the developed method for determining BPA. In analyzing model solutions prepared in distilled water, the limit of detection (LOD) is 0.3 ng/L. In analyzing river water, the LOD increases by approximately 2 times. In analyzing soils, LOD = 2.2 ng/kg dry weight. Soils, compared to water bodies, contain a larger number of interfering components; the sensitivity of the method is reduced by 7–8 times. Bottom sediments are even more contaminated; the LOD more than doubles compared to the determination of BPA in soils.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Analytical Chemistry
Journal of Analytical Chemistry 化学-分析化学
CiteScore
2.10
自引率
9.10%
发文量
146
审稿时长
13 months
期刊介绍: The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信